Arthur F Gmitro

  • 3471 Citations
  • 31 h-Index
1979 …2019
If you made any changes in Pure, your changes will be visible here soon.

Research Output 1979 2016

  • 3471 Citations
  • 31 h-Index
  • 86 Article
  • 70 Conference contribution
  • 1 Chapter
  • 1 Editorial
Filter
Article
2016
3 Citations (Scopus)

Characterization of TCP-1 probes for molecular imaging of colon cancer

Liu, Z., Gray, B. D., Barber, C., Bernas, M. J., Cai, M., Furenlid, L. R., Rouse, A. R., Patel, C., Banerjee, B., Liang, R., Gmitro, A. F., Witte, M. H., Pak, K. Y. & Woolfenden, J. M., Oct 10 2016, In : Journal of Controlled Release. 239, p. 223-230 8 p.

Research output: Contribution to journalArticle

Molecular Imaging
Colonic Neoplasms
Heterografts
Colorectal Neoplasms
Peptides
5 Citations (Scopus)
Ovarian Neoplasms
Area Under Curve
ROC Curve
Neoplasms
Laparoscopes
2015
4 Citations (Scopus)

Analysis of multimode fiber bundles for endoscopic spectral-domain optical coherence tomography

Risi, M. D., Makhlouf, H., Rouse, A. R. & Gmitro, A. F., 2015, In : Applied Optics. 54, 1, p. 101-113 13 p.

Research output: Contribution to journalArticle

Multimode fibers
Optical tomography
bundles
tomography
fibers
7 Citations (Scopus)

Dynamic oxygenation measurements using a phosphorescent coating within a mammary window chamber mouse model

Schafer, R. & Gmitro, A. F., 2015, In : Biomedical Optics Express. 6, 2, p. 639-650 12 p.

Research output: Contribution to journalArticle

Partial Pressure
oxygenation
partial pressure
mice
Breast
4 Citations (Scopus)

Fluorescence and reflectance spectral imaging system for a murine mammary window chamber model

Leung, H. M. & Gmitro, A. F., 2015, In : Biomedical Optics Express. 6, 8, p. 2887-2894 8 p., A002.

Research output: Contribution to journalArticle

spectral reflectance
breast
Breast
tumors
chambers
2014
5 Citations (Scopus)

Confocal microlaparoscope for imaging the fallopian tube

Wu, T. Y., Rouse, A. R., Chambers, S. K., Hatch, K. D. & Gmitro, A. F., Nov 1 2014, In : Journal of Biomedical Optics. 19, 11, 116010.

Research output: Contribution to journalArticle

tubes
Imaging techniques
ovaries
cancer
Animals
5 Citations (Scopus)

Design and performance of a multi-point scan confocal microendoscope

Risi, M. D., Makhlouf, H., Rouse, A. R., Tanbakuchi, A. A. & Gmitro, A. F., Dec 1 2014, In : Photonics. 1, 4, p. 421-431 11 p.

Research output: Contribution to journalArticle

Lighting
Research Design
Fluorescence
Scanning
Imaging techniques
12 Citations (Scopus)

Multi-modality imaging of a murine mammary window chamber for breast cancer research

Schafer, R., Leung, H. M. & Gmitro, A. F., 2014, In : BioTechniques. 57, 1, p. 45-50 6 p.

Research output: Contribution to journalArticle

Breast
Breast Neoplasms
Imaging techniques
Optical Imaging
Research
2013
4 Citations (Scopus)

Ultrathin single-channel fiberscopes for biomedical imaging

Kano, A., Rouse, A. R. & Gmitro, A. F., 2013, In : Journal of Biomedical Optics. 18, 1, 016013.

Research output: Contribution to journalArticle

Lighting
illumination
Imaging techniques
numerical aperture
bundles
2012
5 Citations (Scopus)

Error analysis of ratiometric imaging of extracellular pH in a window chamber model

Lin, Y., Wu, T. Y. & Gmitro, A. F., Apr 2012, In : Journal of Biomedical Optics. 17, 4, 046004-1.

Research output: Contribution to journalArticle

error analysis
Error analysis
chambers
Imaging techniques
Instrument errors
2011
13 Citations (Scopus)

Dual modality fluorescence confocal and spectral-domain optical coherence tomography microendoscope

Makhlouf, H., Rouse, A. R. & Gmitro, A. F., Mar 1 2011, In : Biomedical Optics Express. 2, 3, p. 634-644 11 p.

Research output: Contribution to journalArticle

Optical Coherence Tomography
tomography
Fluorescence
fluorescence
imaging techniques
3 Citations (Scopus)

Errors in confocal fluorescence ratiometric imaging microscopy due to chromatic aberration

Lin, Y. & Gmitro, A. F., Jan 1 2011, In : Applied Optics. 50, 1, p. 95-102 8 p.

Research output: Contribution to journalArticle

Fluorophores
Aberrations
aberration
Microscopic examination
Microscopes
2010
58 Citations (Scopus)

In vivo imaging of ovarian tissue using a novel confocal microlaparoscope

Tanbakuchi, A. A., Udovich, J. A., Rouse, A. R., Hatch, K. D. & Gmitro, A. F., Jan 2010, In : American Journal of Obstetrics and Gynecology. 202, 1

Research output: Contribution to journalArticle

Ovary
Equipment and Supplies
Epithelium
Biopsy
Acridine Orange
2 Citations (Scopus)
Optical Imaging
statistical analysis
Microscopy
Statistical methods
Microscopic examination
2009
16 Citations (Scopus)

Assessment of acridine orange and SYTO 16 for in vivo imaging of the peritoneal tissues in mice

Udovich, J. A., Besselsen, D. G. & Gmitro, A. F., May 2009, In : Journal of Microscopy. 234, 2, p. 124-129 6 p.

Research output: Contribution to journalArticle

Acridine Orange
Coloring Agents
Injections
Endoscopes
Confidence Intervals
70 Citations (Scopus)

Clinical confocal microlaparoscope for real-time in vivo optical biopsies

Tanbakuchi, A. A., Rouse, A. R., Udovich, J. A., Hatch, K. D. & Gmitro, A. F., 2009, In : Journal of Biomedical Optics. 14, 4, 044030.

Research output: Contribution to journalArticle

Biopsy
Tissue
Histology
cancer
Contrast Media
21 Citations (Scopus)

Monte Carlo characterization of parallelized fluorescence confocal systems imaging in turbid media

Tanbakuchi, A. A., Rouse, A. R. & Gmitro, A. F., 2009, In : Journal of Biomedical Optics. 14, 4, 044024.

Research output: Contribution to journalArticle

Imaging systems
apertures
Fluorescence
Tissue
fluorescence
7 Citations (Scopus)

Optical biopsy with confocal microendoscopy

Gmitro, A. F. & Rouse, A. R., 2009, In : Optics and Photonics News. 20, 11, p. 28-33 6 p.

Research output: Contribution to journalArticle

Biopsy
Microscopes
microscopes
Single mode fibers
Imaging techniques
19 Citations (Scopus)

Rapid water and lipid imaging with T2 mapping using a radial IDEAL-GRASE technique

Li, Z., Graff, C., Gmitro, A. F., Squire, S. W., Bilgin, A., Outwater, E. K. & Altbach, M. I., Jun 2009, In : Magnetic Resonance in Medicine. 61, 6, p. 1415-1424 10 p.

Research output: Contribution to journalArticle

Lipids
Water
Fats
Least-Squares Analysis
2008
134 Citations (Scopus)

Bone marrow edema pattern in advanced hip osteoarthritis: Quantitative assessment with magnetic resonance imaging and correlation with clinical examination, radiographic findings, and histopathology

Taljanovic, M., Graham, A. R., Benjamin, J. B., Gmitro, A. F., Krupinski, E. A., Schwartz, S. A., Hunter, T. B. & Resnick, D. L., May 2008, In : Skeletal Radiology. 37, 5, p. 423-431 9 p.

Research output: Contribution to journalArticle

Hip Osteoarthritis
Edema
Bone Marrow
Magnetic Resonance Imaging
Hip
32 Citations (Scopus)

Computer-aided identification of ovarian cancer in confocal microendoscope images

Srivastava, S., Rodriguez, J. J., Rouse, A. R., Brewer, M. A. & Gmitro, A. F., 2008, In : Journal of Biomedical Optics. 13, 2, 024021.

Research output: Contribution to journalArticle

Discriminant Analysis
Discriminant analysis
Ovarian Neoplasms
cancer
classifiers
17 Citations (Scopus)

Direct imaging of radionuclide-produced electrons and positrons with an ultrathin phosphor

Chen, L., Gobar, L. S., Knowles, N. G., Liu, Z., Gmitro, A. F. & Barrett, H. H., Jul 1 2008, In : Journal of Nuclear Medicine. 49, 7, p. 1141-1145 5 p.

Research output: Contribution to journalArticle

Radionuclide Imaging
Electrons
Isotopes
Sodium Pertechnetate Tc 99m
Lenses
52 Citations (Scopus)

Multispectral confocal microendoscope for in vivo and in situ imaging

Makhlouf, H., Gmitro, A. F., Tanbakuchi, A. A., Udovich, J. A. & Rouse, A. R., 2008, In : Journal of Biomedical Optics. 13, 4, 044016.

Research output: Contribution to journalArticle

Imaging techniques
fluorescence
Fluorescence
Tissue
Catheters
41 Citations (Scopus)

Spectral background and transmission characteristics of fiber optic imaging bundles

Udovich, J. A., Kirkpatrick, N. D., Kano, A., Tanbakuchi, A., Utzinger, U. & Gmitro, A. F., Sep 1 2008, In : Applied Optics. 47, 25, p. 4560-4568 9 p.

Research output: Contribution to journalArticle

Fiber optics
bundles
fiber optics
Imaging techniques
Fibers
2007
22 Citations (Scopus)

Fast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm

Li, Z., Gmitro, A. F., Bilgin, A. & Altbach, M. I., Jun 2007, In : Magnetic Resonance in Medicine. 57, 6, p. 1047-1057 11 p.

Research output: Contribution to journalArticle

Lipids
Water
Least-Squares Analysis
Fats
2006
443 Citations (Scopus)

Acid-mediated tumor invasion: A multidisciplinary study

Gatenby, R. A., Gawlinski, E. T., Gmitro, A. F., Kaylor, B. & Gillies, R. J., May 15 2006, In : Cancer Research. 66, 10, p. 5216-5223 8 p.

Research output: Contribution to journalArticle

Acids
Neoplasms
Glucose
Extracellular Matrix
Cathepsin B
2005
2 Citations (Scopus)

Interleaved acquisition of lipid and water images of the heart using a double-inversion fast spin-echo method

Altbach, M. I., Li, Z., Bilgin, A., Marcus, F. I., Sorrell, V., Gmitro, A. F. & Bluemke, D. A., Dec 2005, In : Magnetic Resonance in Medicine. 54, 6, p. 1562-1568 7 p.

Research output: Contribution to journalArticle

Lipids
Water
Arrhythmogenic Right Ventricular Dysplasia
Artifacts
Myocardium
11 Citations (Scopus)

Isotropic diffusion weighting in radial fast spin-echo magnetic resonance imaging

Sarlls, J. E., Newbould, R. D., Altbach, M. I., Gmitro, A. F., Seeger, J. & Trouard, T. T., Jun 2005, In : Magnetic Resonance in Medicine. 53, 6, p. 1347-1354 8 p.

Research output: Contribution to journalArticle

Magnetic Resonance Imaging
Diffusion Magnetic Resonance Imaging
Artifacts
Anisotropy
Direction compound
25 Citations (Scopus)
Artifacts
Noise
Datasets
16 Citations (Scopus)

Radial GRASE: Implementation and applications

Gmitro, A. F., Kono, M., Theilmann, R. J., Altbach, M. I., Li, Z. & Trouard, T. T., Jun 2005, In : Magnetic Resonance in Medicine. 53, 6, p. 1363-1371 9 p.

Research output: Contribution to journalArticle

Fats
Water
Datasets
2004
107 Citations (Scopus)

Design and demonstration of a miniature catheter for a confocal microendoscope

Rouse, A. R., Kano, A., Udovich, J. A., Kroto, S. M. & Gmitro, A. F., Nov 1 2004, In : Applied Optics. 43, 31, p. 5763-5771 9 p.

Research output: Contribution to journalArticle

Catheters
fiber optics
reproductive systems
Demonstrations
Endoscopy
63 Citations (Scopus)

Imaging of the ovary

Brewer, M. A., Utzinger, U., Barton, J. K., Hoying, J. B., Kirkpatrick, N. D., Brands, W. R., Davis, J. R., Hunt, K., Stevens, S. J. & Gmitro, A. F., Dec 2004, In : Technology in Cancer Research and Treatment. 3, 6, p. 617-627 11 p.

Research output: Contribution to journalArticle

Ovary
Fluorescence Spectrometry
Optical Coherence Tomography
Confocal Microscopy
Ovarian Neoplasms
8 Citations (Scopus)

Spatially varying steady state longitudinal magnetization in distant dipolar field-based sequences

Corum, C. A. & Gmitro, A. F., Nov 2004, In : Journal of Magnetic Resonance. 171, 1, p. 131-134 4 p.

Research output: Contribution to journalArticle

Magnetization
Imaging techniques
magnetization
profiles
Spectrum Analysis
27 Citations (Scopus)

View-Ordering in Radial Fast Spin-Echo Imaging

Theilmann, R. J., Gmitro, A. F., Altbach, M. I. & Trouard, T. T., Apr 2004, In : Magnetic Resonance in Medicine. 51, 4, p. 768-774 7 p.

Research output: Contribution to journalArticle

Artifacts
Magnetic Resonance Imaging
2003
21 Citations (Scopus)

Cortical mechanisms for acquisition and performance of bimanual motor sequences

De Weerd, P., Reinke, K., Ryan, T. L., McIsaac, T., Perschler, P., Schnyer, D., Trouard, T. T. & Gmitro, A. F., Aug 1 2003, In : NeuroImage. 19, 4, p. 1405-1416 12 p.

Research output: Contribution to journalArticle

Motor Cortex
Fingers
Parietal Lobe
Long-Term Memory
Magnetic Resonance Imaging
79 Citations (Scopus)

Sleep-disordered breathing, pharyngeal size and soft tissue anatomy in children

Fregosi, R. F., Quan, S. F., Kaemingk, K. L., Morgan, W. J., Goodwin, J. L., Cabrera, R. & Gmitro, A. F., Nov 2003, In : Journal of Applied Physiology. 95, 5, p. 2030-2038 9 p.

Research output: Contribution to journalArticle

Sleep Apnea Syndromes
Apnea
Anatomy
Soft Palate
Palatine Tonsil
2002
48 Citations (Scopus)

Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver

Altbach, M. I., Outwater, E. K., Trouard, T. T., Krupinski, E. A., Theilmann, R. J., Stopeck, A. T., Kono, M. & Gmitro, A. F., 2002, In : Journal of Magnetic Resonance Imaging. 16, 2, p. 179-189 11 p.

Research output: Contribution to journalArticle

Artifacts
Liver
Hemangioma
Cysts
Datasets
2001
5 Citations (Scopus)

Chemical-shift imaging utilizing the positional shifts along the readout gradient direction

Altbach, M. I., Trouard, T. T., Van De Walle, R., Theilmann, R. J., Clarkson, E. W., Barrett, H. H. & Gmitro, A. F., Nov 2001, In : IEEE Transactions on Medical Imaging. 20, 11, p. 1156-1166 11 p.

Research output: Contribution to journalArticle

Chemical shift
Data acquisition
Magnetic Resonance Imaging
Magnetic resonance
Signal to noise ratio
30 Citations (Scopus)
Hypoglossal Nerve
Tongue
Muscles
Airway Management
Obstructive Sleep Apnea
2000
335 Citations (Scopus)

Adaptive reconstruction of phased array MR imagery

Walsh, D. O., Gmitro, A. F. & Marcellin, M. W., 2000, In : Magnetic Resonance in Medicine. 43, 5, p. 682-690 9 p.

Research output: Contribution to journalArticle

Imagery (Psychotherapy)
Noise
Artifacts
80 Citations (Scopus)

Multispectral imaging with a confocal microendoscope

Rouse, A. R. & Gmitro, A. F., Dec 1 2000, In : Optics Letters. 25, 23, p. 1708-1710 3 p.

Research output: Contribution to journalArticle

slits
fiber optics
microscopes
fluorescence
65 Citations (Scopus)

Reconstruction of MR images from data acquired on a general nonregular grid by pseudoinverse calculation

Van Walle, R. D., Barrett, H. H., Myers, K. J., Altbach, M. I., Desplanques, B., Gmitro, A. F., Cornells, J. & Lemahieu, I., 2000, In : IEEE Transactions on Medical Imaging. 19, 12, p. 1160-1167 8 p.

Research output: Contribution to journalArticle

Computer-Assisted Image Processing
Image reconstruction
Least-Squares Analysis
Magnetic resonance
Signal-To-Noise Ratio
1999
60 Citations (Scopus)
Artifacts
Diffusion Magnetic Resonance Imaging
Neuroimaging
Datasets
2 Citations (Scopus)

Quantitative phase contrast images to quantitate flow in a rat model of microgravity

Hays, A. M., Keller, R. L., Gmitro, A. F., Alpbach, M. I., Sridhar, K. R., Balagtas, M. P. & Witten, M. L., Mar 1999, In : Aviation Space and Environmental Medicine. 70, 3 I, p. 225-229 5 p.

Research output: Contribution to journalArticle

Bearings (structural)
Weightlessness
Microgravity
Hindlimb
Inferior Vena Cava
143 Citations (Scopus)

Slit-scanning confocal microendoscope for high-resolution in vivo imaging

Sabharwal, Y. S., Rouse, A. R., Donaldson, L., Hopkins, M. F. & Gmitro, A. F., Dec 1 1999, In : Applied Optics. 38, 34, p. 7133-7144 12 p.

Research output: Contribution to journalArticle

slits
Tissue
Scanning
Imaging techniques
scanning
1998
3 Citations (Scopus)

Image manipulation and error estimation for MRI analysis

Plante, E. M., Uecker, A., Senkfor, A. & Gmitro, A. F., Dec 1 1998, In : Journal of Neuroscience Methods. 85, 2, p. 175-180 6 p.

Research output: Contribution to journalArticle

Research Personnel
1997
26 Citations (Scopus)

MRI and NMR spectroscopy of the lipids of atherosclerotic plaque in rabbits and humans

Trouard, T. T., Altbach, M. I., Hunter, G. C., Eskelson, C. D. & Gmitro, A. F., Jul 1997, In : Magnetic Resonance in Medicine. 38, 1, p. 19-26 8 p.

Research output: Contribution to journalArticle

Atherosclerotic Plaques
Magnetic Resonance Spectroscopy
Rabbits
Lipids
Weights and Measures

Quantitative phase contrast images of flow within the rat vena cava in a 45° rat head down tilt (HDT) model of simulated microgravity

Hays, A. M., Keller, R. L., Gmitro, A. F., Alpbach, M., Padilla, M. T., Balagtas, M. P., O'Donnell, M. & Witten, M. L., 1997, In : FASEB Journal. 11, 3

Research output: Contribution to journalArticle

Head-Down Tilt
microgravity
Weightlessness
vena cava
Venae Cavae
33 Citations (Scopus)

Rapid observation of unfixed, unstained human skin biopsy specimens with confocal microscopy and visualization

Masters, B. R., Aziz, D. J., Gmitro, A. F., Kerr, J. H., O'Grady, T. C. & Goldman, L., 1997, In : Journal of Biomedical Optics. 2, 4, p. 437-445 9 p.

Research output: Contribution to journalArticle

Biopsy
Confocal microscopy
Confocal Microscopy
Skin
Visualization
1996
61 Citations (Scopus)

Analysis and comparison of motion-correction techniques in Diffusion-Weighted Imaging

Trouard, T. T., Sabharwal, Y., Altbach, M. I. & Gmitro, A. F., Nov 1996, In : Journal of Magnetic Resonance Imaging. 6, 6, p. 925-935 11 p.

Research output: Contribution to journalArticle

Artifacts