A Doppler echocardiographic method for calculating volume flow across the tricuspid valve: Correlative laboratory and clinical studies

E. J. Meijboom, S. Horowitz, L. M. Valdes-Cruz, D. J. Sahn, Douglas F Larson, C. Oliveira Lima

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a 4-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the 4-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in 4-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and 4-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.

Original languageEnglish (US)
Pages (from-to)551-556
Number of pages6
JournalCirculation
Volume71
Issue number3
StatePublished - 1985
Externally publishedYes

Fingerprint

Tricuspid Valve
Thermodilution
Electromagnetic Phenomena
Cardiac Catheterization
Thigh
Cardiac Output
Aorta
Thorax
Clinical Studies
Dogs
Lung

ASJC Scopus subject areas

  • Physiology
  • Cardiology and Cardiovascular Medicine

Cite this

Meijboom, E. J., Horowitz, S., Valdes-Cruz, L. M., Sahn, D. J., Larson, D. F., & Oliveira Lima, C. (1985). A Doppler echocardiographic method for calculating volume flow across the tricuspid valve: Correlative laboratory and clinical studies. Circulation, 71(3), 551-556.

A Doppler echocardiographic method for calculating volume flow across the tricuspid valve : Correlative laboratory and clinical studies. / Meijboom, E. J.; Horowitz, S.; Valdes-Cruz, L. M.; Sahn, D. J.; Larson, Douglas F; Oliveira Lima, C.

In: Circulation, Vol. 71, No. 3, 1985, p. 551-556.

Research output: Contribution to journalArticle

Meijboom, EJ, Horowitz, S, Valdes-Cruz, LM, Sahn, DJ, Larson, DF & Oliveira Lima, C 1985, 'A Doppler echocardiographic method for calculating volume flow across the tricuspid valve: Correlative laboratory and clinical studies', Circulation, vol. 71, no. 3, pp. 551-556.
Meijboom, E. J. ; Horowitz, S. ; Valdes-Cruz, L. M. ; Sahn, D. J. ; Larson, Douglas F ; Oliveira Lima, C. / A Doppler echocardiographic method for calculating volume flow across the tricuspid valve : Correlative laboratory and clinical studies. In: Circulation. 1985 ; Vol. 71, No. 3. pp. 551-556.
@article{cc80c15ed63a4ace82397a2cda146de8,
title = "A Doppler echocardiographic method for calculating volume flow across the tricuspid valve: Correlative laboratory and clinical studies",
abstract = "In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a 4-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the 4-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in 4-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and 4-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.",
author = "Meijboom, {E. J.} and S. Horowitz and Valdes-Cruz, {L. M.} and Sahn, {D. J.} and Larson, {Douglas F} and {Oliveira Lima}, C.",
year = "1985",
language = "English (US)",
volume = "71",
pages = "551--556",
journal = "Circulation",
issn = "0009-7322",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - A Doppler echocardiographic method for calculating volume flow across the tricuspid valve

T2 - Correlative laboratory and clinical studies

AU - Meijboom, E. J.

AU - Horowitz, S.

AU - Valdes-Cruz, L. M.

AU - Sahn, D. J.

AU - Larson, Douglas F

AU - Oliveira Lima, C.

PY - 1985

Y1 - 1985

N2 - In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a 4-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the 4-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in 4-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and 4-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.

AB - In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a 4-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the 4-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in 4-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and 4-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.

UR - http://www.scopus.com/inward/record.url?scp=0021955046&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021955046&partnerID=8YFLogxK

M3 - Article

C2 - 3971526

AN - SCOPUS:0021955046

VL - 71

SP - 551

EP - 556

JO - Circulation

JF - Circulation

SN - 0009-7322

IS - 3