A high-performance microsystem for isolating circulating tumor cells

Xiangjun Zheng, Luthur Siu Lun Cheung, Joyce Schroeder, Linan Jiang, Yitshak Zohar

Research output: Contribution to journalArticle

50 Citations (Scopus)

Abstract

A unique flow field pattern in a bio-functional microchannel is utilized to significantly enhance the performance of a microsystem developed for selectively isolating circulating tumor cells from cell suspensions. For high performance of such systems, disposal of maximum non-target species is just as important as retention of maximum target species; unfortunately, most studies ignore or fail to report this aspect. Therefore, sensitivity and specificity are introduced as quantitative criteria to evaluate the system performance enabling a direct comparison among systems employing different techniques. The newly proposed fluidic scheme combines a slow flow field, for maximum target-cell attachment, followed by a faster flow field, for maximum detachment of non-target cells. Suspensions of homogeneous or binary mixtures of circulating breast tumor cells, with varying relative concentrations, were driven through antibody-functionalized microchannels. Either EpCAM or cadherin-11 transmembrane receptors were targeted to selectively capture target cells from the suspensions. Cadherin-11-expressing MDA-MB-231 cancer cells were used as target cells, while BT-20 cells were used as non-target cells as they do not express cadherin-11. The attachment and detachment of these two cell lines are characterized, and a two-step attachment/detachment flow field pattern is implemented to enhance the system performance in capturing target cells from binary mixtures. While the system sensitivity remains high, above 0.95, the specificity increases from about 0.85 to 0.95 solely due to the second detachment step even for a 1:1000 relative concentration of the target cells.

Original languageEnglish (US)
Pages (from-to)3269-3276
Number of pages8
JournalLab on a Chip - Miniaturisation for Chemistry and Biology
Volume11
Issue number19
DOIs
StatePublished - Oct 7 2011

Fingerprint

Circulating Neoplastic Cells
Microsystems
Tumors
Flow fields
Cells
Suspensions
Binary mixtures
Microchannels
Fluidics
Antibodies
osteoblast cadherin
Breast Neoplasms

ASJC Scopus subject areas

  • Biochemistry
  • Chemistry(all)
  • Bioengineering
  • Biomedical Engineering

Cite this

A high-performance microsystem for isolating circulating tumor cells. / Zheng, Xiangjun; Cheung, Luthur Siu Lun; Schroeder, Joyce; Jiang, Linan; Zohar, Yitshak.

In: Lab on a Chip - Miniaturisation for Chemistry and Biology, Vol. 11, No. 19, 07.10.2011, p. 3269-3276.

Research output: Contribution to journalArticle

@article{b9ba2d458f04435b9c994fa63f4aa379,
title = "A high-performance microsystem for isolating circulating tumor cells",
abstract = "A unique flow field pattern in a bio-functional microchannel is utilized to significantly enhance the performance of a microsystem developed for selectively isolating circulating tumor cells from cell suspensions. For high performance of such systems, disposal of maximum non-target species is just as important as retention of maximum target species; unfortunately, most studies ignore or fail to report this aspect. Therefore, sensitivity and specificity are introduced as quantitative criteria to evaluate the system performance enabling a direct comparison among systems employing different techniques. The newly proposed fluidic scheme combines a slow flow field, for maximum target-cell attachment, followed by a faster flow field, for maximum detachment of non-target cells. Suspensions of homogeneous or binary mixtures of circulating breast tumor cells, with varying relative concentrations, were driven through antibody-functionalized microchannels. Either EpCAM or cadherin-11 transmembrane receptors were targeted to selectively capture target cells from the suspensions. Cadherin-11-expressing MDA-MB-231 cancer cells were used as target cells, while BT-20 cells were used as non-target cells as they do not express cadherin-11. The attachment and detachment of these two cell lines are characterized, and a two-step attachment/detachment flow field pattern is implemented to enhance the system performance in capturing target cells from binary mixtures. While the system sensitivity remains high, above 0.95, the specificity increases from about 0.85 to 0.95 solely due to the second detachment step even for a 1:1000 relative concentration of the target cells.",
author = "Xiangjun Zheng and Cheung, {Luthur Siu Lun} and Joyce Schroeder and Linan Jiang and Yitshak Zohar",
year = "2011",
month = "10",
day = "7",
doi = "10.1039/c1lc20331b",
language = "English (US)",
volume = "11",
pages = "3269--3276",
journal = "Lab on a Chip - Miniaturisation for Chemistry and Biology",
issn = "1473-0197",
publisher = "Royal Society of Chemistry",
number = "19",

}

TY - JOUR

T1 - A high-performance microsystem for isolating circulating tumor cells

AU - Zheng, Xiangjun

AU - Cheung, Luthur Siu Lun

AU - Schroeder, Joyce

AU - Jiang, Linan

AU - Zohar, Yitshak

PY - 2011/10/7

Y1 - 2011/10/7

N2 - A unique flow field pattern in a bio-functional microchannel is utilized to significantly enhance the performance of a microsystem developed for selectively isolating circulating tumor cells from cell suspensions. For high performance of such systems, disposal of maximum non-target species is just as important as retention of maximum target species; unfortunately, most studies ignore or fail to report this aspect. Therefore, sensitivity and specificity are introduced as quantitative criteria to evaluate the system performance enabling a direct comparison among systems employing different techniques. The newly proposed fluidic scheme combines a slow flow field, for maximum target-cell attachment, followed by a faster flow field, for maximum detachment of non-target cells. Suspensions of homogeneous or binary mixtures of circulating breast tumor cells, with varying relative concentrations, were driven through antibody-functionalized microchannels. Either EpCAM or cadherin-11 transmembrane receptors were targeted to selectively capture target cells from the suspensions. Cadherin-11-expressing MDA-MB-231 cancer cells were used as target cells, while BT-20 cells were used as non-target cells as they do not express cadherin-11. The attachment and detachment of these two cell lines are characterized, and a two-step attachment/detachment flow field pattern is implemented to enhance the system performance in capturing target cells from binary mixtures. While the system sensitivity remains high, above 0.95, the specificity increases from about 0.85 to 0.95 solely due to the second detachment step even for a 1:1000 relative concentration of the target cells.

AB - A unique flow field pattern in a bio-functional microchannel is utilized to significantly enhance the performance of a microsystem developed for selectively isolating circulating tumor cells from cell suspensions. For high performance of such systems, disposal of maximum non-target species is just as important as retention of maximum target species; unfortunately, most studies ignore or fail to report this aspect. Therefore, sensitivity and specificity are introduced as quantitative criteria to evaluate the system performance enabling a direct comparison among systems employing different techniques. The newly proposed fluidic scheme combines a slow flow field, for maximum target-cell attachment, followed by a faster flow field, for maximum detachment of non-target cells. Suspensions of homogeneous or binary mixtures of circulating breast tumor cells, with varying relative concentrations, were driven through antibody-functionalized microchannels. Either EpCAM or cadherin-11 transmembrane receptors were targeted to selectively capture target cells from the suspensions. Cadherin-11-expressing MDA-MB-231 cancer cells were used as target cells, while BT-20 cells were used as non-target cells as they do not express cadherin-11. The attachment and detachment of these two cell lines are characterized, and a two-step attachment/detachment flow field pattern is implemented to enhance the system performance in capturing target cells from binary mixtures. While the system sensitivity remains high, above 0.95, the specificity increases from about 0.85 to 0.95 solely due to the second detachment step even for a 1:1000 relative concentration of the target cells.

UR - http://www.scopus.com/inward/record.url?scp=80052526439&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052526439&partnerID=8YFLogxK

U2 - 10.1039/c1lc20331b

DO - 10.1039/c1lc20331b

M3 - Article

C2 - 21837324

AN - SCOPUS:80052526439

VL - 11

SP - 3269

EP - 3276

JO - Lab on a Chip - Miniaturisation for Chemistry and Biology

JF - Lab on a Chip - Miniaturisation for Chemistry and Biology

SN - 1473-0197

IS - 19

ER -