A pulsed Doppler echocardiographic method for calculation of pulmonary and systemic flow: Accuracy in a canine model with ventricular septal defect

L. M. Valdes-Cruz, S. Horowitz, E. Mesel, D. J. Sahn, D. C. Fisher, D. Larson, S. J. Goldberg, H. D. Allen

Research output: Contribution to journalArticle

43 Scopus citations

Abstract

This study was designed to assess the accuracy of a quantitative, two-dimensional, range-gated, Doppler echocardiographic method for estimating systemic and pulmonary flows by comparing them with simultaneous electromagnetic (EM) flow-meter determinations in an open-chest canine model with a ventricular septal defect, the size of which was varied. With each step-by-step variation in defect size, systemic and pulmonary flows were estimated by the Doppler method and matched to simultaneous pulmonary and aortic EM flow-meter recordings. The Doppler value for systemic blood flow was obtained by measuring the size of the aorta on a two-dimensional echocardiographic image and sampling blood flow velocity in the ascending aorta. Because of high flow velocities and spectral broadening on the pulmonary artery Doppler flow curves in the presence of ventricular septal defects, pulmonary blood flow was measured as pulmonary venous return through the mitral valve orifice, with the size of the mitral orifice measured on the short axis by two-dimensional echocardiography and with transflow curves obtained from apical views. For a total of 32 left-to-right shunt magnitudes obtained in 10 dogs, excellent correlations were found between ascending aortic Doppler and EM flow-meter values (r = .91, SEE - 0.11), between Doppler mitzal valve flow and EM flow-meter main pulmonary artary flow valves (2 = .93, SEE = 0.32), and between Doppler and EM flow-meter determinations of the ratio of pulmonary to systemic flow (r = .93, SEE = 0.52). Our study demonstrates the accuracy of this two-dimensional echocardiographic Doppler method for measuring pulmonary and systemic flows and their ratios in the presence of ventricular septal defects.

Original languageEnglish (US)
Pages (from-to)597-602
Number of pages6
JournalUnknown Journal
Volume68
Issue number3 I
DOIs
StatePublished - Jan 1 1983

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Fingerprint Dive into the research topics of 'A pulsed Doppler echocardiographic method for calculation of pulmonary and systemic flow: Accuracy in a canine model with ventricular septal defect'. Together they form a unique fingerprint.

  • Cite this