A simple knowledge-based tool for stereotactic radiosurgery pre-planning

Daniel S. Goldbaum, Justin D. Hurley, Russell J. Hamilton

Research output: Contribution to journalArticle

Abstract

We studied the dosimetry of single-isocenter treatment plans generated to treat a solitary intracranial lesion using linac-based stereotactic radiosurgery (SRS). A common metric for evaluating SRS plan quality is the volume of normal brain tissue irradiated by a dose of at least 12 Gy (V12), which is important because multiple studies have shown a strong correlation between V12 and incidence of radiation necrosis. Unrealistic expectations for values of V12 can lead to wasted planning time. We present a model that estimates V12 without having to construct a full treatment plan. This model was derived by retrospectively analyzing 50 SRS treatment plans, each clinically approved for delivery using circular collimator cone arc therapy (CAT). Each case was re-planned for delivery via dynamic conformal arc therapy (DCAT), and then scaling arguments were used to extend dosimetric data to account for different prescription dose (PD) values (15, 18, 21, or 24 Gy). We determined a phenomenological expression for the total volume receiving at least 12 Gy (TV12) as a function of both planning target volume (PTV) and PD: (Formula presented.), where {a, c, n, d} are fit parameters, and a separate set of values is determined for each plan type. In addition, we generated a sequence of plots to clarify how the relationship between conformity index (CI) and TV12 depends on plan type (CAT vs DCAT), PTV, and PD. These results can be used to suggest realistic plan parameters and planning goals before the start of treatment planning. In the absence of access to more sophisticated pre-planning tools, this model can be locally generated and implemented at relatively low cost with respect to time, money, and expertise.

Original languageEnglish (US)
Pages (from-to)97-108
Number of pages12
JournalJournal of Applied Clinical Medical Physics
Volume20
Issue number12
DOIs
StatePublished - Dec 1 2019

Fingerprint

Radiosurgery
planning
Planning
therapy
arcs
Cones
dosage
Therapeutics
delivery
cones
Prescriptions
necrosis
Dosimetry
collimators
Brain
lesions
dosimeters
brain
Tissue
incidence

Keywords

  • circular arc therapy (CAT)
  • conformity index (CI)
  • dynamic conformal arc therapy (DCAT)
  • modeling
  • stereotactic radiosurgery (SRS)
  • V12

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Cite this

A simple knowledge-based tool for stereotactic radiosurgery pre-planning. / Goldbaum, Daniel S.; Hurley, Justin D.; Hamilton, Russell J.

In: Journal of Applied Clinical Medical Physics, Vol. 20, No. 12, 01.12.2019, p. 97-108.

Research output: Contribution to journalArticle

@article{3b29fdbec1664378b09c0ca3261742b6,
title = "A simple knowledge-based tool for stereotactic radiosurgery pre-planning",
abstract = "We studied the dosimetry of single-isocenter treatment plans generated to treat a solitary intracranial lesion using linac-based stereotactic radiosurgery (SRS). A common metric for evaluating SRS plan quality is the volume of normal brain tissue irradiated by a dose of at least 12 Gy (V12), which is important because multiple studies have shown a strong correlation between V12 and incidence of radiation necrosis. Unrealistic expectations for values of V12 can lead to wasted planning time. We present a model that estimates V12 without having to construct a full treatment plan. This model was derived by retrospectively analyzing 50 SRS treatment plans, each clinically approved for delivery using circular collimator cone arc therapy (CAT). Each case was re-planned for delivery via dynamic conformal arc therapy (DCAT), and then scaling arguments were used to extend dosimetric data to account for different prescription dose (PD) values (15, 18, 21, or 24 Gy). We determined a phenomenological expression for the total volume receiving at least 12 Gy (TV12) as a function of both planning target volume (PTV) and PD: (Formula presented.), where {a, c, n, d} are fit parameters, and a separate set of values is determined for each plan type. In addition, we generated a sequence of plots to clarify how the relationship between conformity index (CI) and TV12 depends on plan type (CAT vs DCAT), PTV, and PD. These results can be used to suggest realistic plan parameters and planning goals before the start of treatment planning. In the absence of access to more sophisticated pre-planning tools, this model can be locally generated and implemented at relatively low cost with respect to time, money, and expertise.",
keywords = "circular arc therapy (CAT), conformity index (CI), dynamic conformal arc therapy (DCAT), modeling, stereotactic radiosurgery (SRS), V12",
author = "Goldbaum, {Daniel S.} and Hurley, {Justin D.} and Hamilton, {Russell J.}",
year = "2019",
month = "12",
day = "1",
doi = "10.1002/acm2.12770",
language = "English (US)",
volume = "20",
pages = "97--108",
journal = "Journal of Applied Clinical Medical Physics",
issn = "1526-9914",
publisher = "American Institute of Physics Publising LLC",
number = "12",

}

TY - JOUR

T1 - A simple knowledge-based tool for stereotactic radiosurgery pre-planning

AU - Goldbaum, Daniel S.

AU - Hurley, Justin D.

AU - Hamilton, Russell J.

PY - 2019/12/1

Y1 - 2019/12/1

N2 - We studied the dosimetry of single-isocenter treatment plans generated to treat a solitary intracranial lesion using linac-based stereotactic radiosurgery (SRS). A common metric for evaluating SRS plan quality is the volume of normal brain tissue irradiated by a dose of at least 12 Gy (V12), which is important because multiple studies have shown a strong correlation between V12 and incidence of radiation necrosis. Unrealistic expectations for values of V12 can lead to wasted planning time. We present a model that estimates V12 without having to construct a full treatment plan. This model was derived by retrospectively analyzing 50 SRS treatment plans, each clinically approved for delivery using circular collimator cone arc therapy (CAT). Each case was re-planned for delivery via dynamic conformal arc therapy (DCAT), and then scaling arguments were used to extend dosimetric data to account for different prescription dose (PD) values (15, 18, 21, or 24 Gy). We determined a phenomenological expression for the total volume receiving at least 12 Gy (TV12) as a function of both planning target volume (PTV) and PD: (Formula presented.), where {a, c, n, d} are fit parameters, and a separate set of values is determined for each plan type. In addition, we generated a sequence of plots to clarify how the relationship between conformity index (CI) and TV12 depends on plan type (CAT vs DCAT), PTV, and PD. These results can be used to suggest realistic plan parameters and planning goals before the start of treatment planning. In the absence of access to more sophisticated pre-planning tools, this model can be locally generated and implemented at relatively low cost with respect to time, money, and expertise.

AB - We studied the dosimetry of single-isocenter treatment plans generated to treat a solitary intracranial lesion using linac-based stereotactic radiosurgery (SRS). A common metric for evaluating SRS plan quality is the volume of normal brain tissue irradiated by a dose of at least 12 Gy (V12), which is important because multiple studies have shown a strong correlation between V12 and incidence of radiation necrosis. Unrealistic expectations for values of V12 can lead to wasted planning time. We present a model that estimates V12 without having to construct a full treatment plan. This model was derived by retrospectively analyzing 50 SRS treatment plans, each clinically approved for delivery using circular collimator cone arc therapy (CAT). Each case was re-planned for delivery via dynamic conformal arc therapy (DCAT), and then scaling arguments were used to extend dosimetric data to account for different prescription dose (PD) values (15, 18, 21, or 24 Gy). We determined a phenomenological expression for the total volume receiving at least 12 Gy (TV12) as a function of both planning target volume (PTV) and PD: (Formula presented.), where {a, c, n, d} are fit parameters, and a separate set of values is determined for each plan type. In addition, we generated a sequence of plots to clarify how the relationship between conformity index (CI) and TV12 depends on plan type (CAT vs DCAT), PTV, and PD. These results can be used to suggest realistic plan parameters and planning goals before the start of treatment planning. In the absence of access to more sophisticated pre-planning tools, this model can be locally generated and implemented at relatively low cost with respect to time, money, and expertise.

KW - circular arc therapy (CAT)

KW - conformity index (CI)

KW - dynamic conformal arc therapy (DCAT)

KW - modeling

KW - stereotactic radiosurgery (SRS)

KW - V12

UR - http://www.scopus.com/inward/record.url?scp=85075313129&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85075313129&partnerID=8YFLogxK

U2 - 10.1002/acm2.12770

DO - 10.1002/acm2.12770

M3 - Article

C2 - 31743563

AN - SCOPUS:85075313129

VL - 20

SP - 97

EP - 108

JO - Journal of Applied Clinical Medical Physics

JF - Journal of Applied Clinical Medical Physics

SN - 1526-9914

IS - 12

ER -