Acoustic source localization in anisotropic plates with “Z” shaped sensor clusters

Shenxin Yin, Zhiwen Cui, Tribikram Kundu

Research output: Research - peer-reviewArticle

Abstract

A new sensor cluster orientation is proposed to localize an acoustic source in a plate from the time difference of arrival (TDOA) with the help of only four to eight sensors. This technique requires neither a priori knowledge of the plate material properties nor a dense array of sensors to localize the acoustic source in isotropic as well as anisotropic plates. It is achieved by placing four sensors in a cluster in the shape of letter “Z” over a small region of the plate and a second Z-shaped cluster at another location of the plate. Experimental results show that it is possible to accurately localize the acoustic source with this new configuration. It reduces the number of sensors required for acoustic source localization in an anisotropic plate. Although one cluster in principle is capable of localizing the acoustic source in absence of any experimental error for accurate source localization in presence of experimental error two such Z-shaped clusters are needed. In the currently available technique three L-shaped clusters having a total of 9 sensors are needed to achieve the same level of confidence in the acoustic source localization. Thus, the proposed new technique reduces the number of sensors by 1 (from 9 to 8) for confidently and accurately predicting the acoustic source.

LanguageEnglish (US)
Pages34-37
Number of pages4
JournalUltrasonics
Volume84
DOIs
StatePublished - Mar 1 2018

Fingerprint

anisotropic plates
acoustics
sensors
arrivals
confidence
configurations

Keywords

  • Acoustic emission
  • Acoustic source localization
  • Anisotropic plate
  • L-shaped clusters
  • Time difference of arrival

ASJC Scopus subject areas

  • Acoustics and Ultrasonics

Cite this

Acoustic source localization in anisotropic plates with “Z” shaped sensor clusters. / Yin, Shenxin; Cui, Zhiwen; Kundu, Tribikram.

In: Ultrasonics, Vol. 84, 01.03.2018, p. 34-37.

Research output: Research - peer-reviewArticle

@article{0ae7876b73884bfa8d1725186cf1111c,
title = "Acoustic source localization in anisotropic plates with “Z” shaped sensor clusters",
abstract = "A new sensor cluster orientation is proposed to localize an acoustic source in a plate from the time difference of arrival (TDOA) with the help of only four to eight sensors. This technique requires neither a priori knowledge of the plate material properties nor a dense array of sensors to localize the acoustic source in isotropic as well as anisotropic plates. It is achieved by placing four sensors in a cluster in the shape of letter “Z” over a small region of the plate and a second Z-shaped cluster at another location of the plate. Experimental results show that it is possible to accurately localize the acoustic source with this new configuration. It reduces the number of sensors required for acoustic source localization in an anisotropic plate. Although one cluster in principle is capable of localizing the acoustic source in absence of any experimental error for accurate source localization in presence of experimental error two such Z-shaped clusters are needed. In the currently available technique three L-shaped clusters having a total of 9 sensors are needed to achieve the same level of confidence in the acoustic source localization. Thus, the proposed new technique reduces the number of sensors by 1 (from 9 to 8) for confidently and accurately predicting the acoustic source.",
keywords = "Acoustic emission, Acoustic source localization, Anisotropic plate, L-shaped clusters, Time difference of arrival",
author = "Shenxin Yin and Zhiwen Cui and Tribikram Kundu",
year = "2018",
month = "3",
doi = "10.1016/j.ultras.2017.10.007",
volume = "84",
pages = "34--37",
journal = "Ultrasonics",
issn = "0041-624X",
publisher = "Elsevier",

}

TY - JOUR

T1 - Acoustic source localization in anisotropic plates with “Z” shaped sensor clusters

AU - Yin,Shenxin

AU - Cui,Zhiwen

AU - Kundu,Tribikram

PY - 2018/3/1

Y1 - 2018/3/1

N2 - A new sensor cluster orientation is proposed to localize an acoustic source in a plate from the time difference of arrival (TDOA) with the help of only four to eight sensors. This technique requires neither a priori knowledge of the plate material properties nor a dense array of sensors to localize the acoustic source in isotropic as well as anisotropic plates. It is achieved by placing four sensors in a cluster in the shape of letter “Z” over a small region of the plate and a second Z-shaped cluster at another location of the plate. Experimental results show that it is possible to accurately localize the acoustic source with this new configuration. It reduces the number of sensors required for acoustic source localization in an anisotropic plate. Although one cluster in principle is capable of localizing the acoustic source in absence of any experimental error for accurate source localization in presence of experimental error two such Z-shaped clusters are needed. In the currently available technique three L-shaped clusters having a total of 9 sensors are needed to achieve the same level of confidence in the acoustic source localization. Thus, the proposed new technique reduces the number of sensors by 1 (from 9 to 8) for confidently and accurately predicting the acoustic source.

AB - A new sensor cluster orientation is proposed to localize an acoustic source in a plate from the time difference of arrival (TDOA) with the help of only four to eight sensors. This technique requires neither a priori knowledge of the plate material properties nor a dense array of sensors to localize the acoustic source in isotropic as well as anisotropic plates. It is achieved by placing four sensors in a cluster in the shape of letter “Z” over a small region of the plate and a second Z-shaped cluster at another location of the plate. Experimental results show that it is possible to accurately localize the acoustic source with this new configuration. It reduces the number of sensors required for acoustic source localization in an anisotropic plate. Although one cluster in principle is capable of localizing the acoustic source in absence of any experimental error for accurate source localization in presence of experimental error two such Z-shaped clusters are needed. In the currently available technique three L-shaped clusters having a total of 9 sensors are needed to achieve the same level of confidence in the acoustic source localization. Thus, the proposed new technique reduces the number of sensors by 1 (from 9 to 8) for confidently and accurately predicting the acoustic source.

KW - Acoustic emission

KW - Acoustic source localization

KW - Anisotropic plate

KW - L-shaped clusters

KW - Time difference of arrival

UR - http://www.scopus.com/inward/record.url?scp=85032880449&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85032880449&partnerID=8YFLogxK

U2 - 10.1016/j.ultras.2017.10.007

DO - 10.1016/j.ultras.2017.10.007

M3 - Article

VL - 84

SP - 34

EP - 37

JO - Ultrasonics