Alfieri repair for post-repair mitral systolic anterior motion in a young child

Zain I Khalpey, Christopher W. Baird, Patrick O. Myers

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

An 11-year-old patient with Marfan syndrome presented with severe mitral and tricuspid regurgitation and underwent mitral valve repair consisting of a vertical folding plasty of a redundant and prolapsing A1, closure of a deep cleft-like A1-A2 indentation, and annuloplasty to 28 mm, and tricuspid valve repair. Post-bypass echocardiography showed significant systolic anterior motion of the mitral valve. The annuloplasty was upsized to 34 mm and the A1 folding plasty taken down. Echocardiography showed persistent systolic anterior motion. An edge-to-edge repair was placed at A1-P1, eliminating all systolic anterior motion. The patient had an uneventful postoperative course and 6-week follow-up.

Original languageEnglish (US)
Pages (from-to)1452-1453
Number of pages2
JournalAnnals of Thoracic Surgery
Volume95
Issue number4
DOIs
StatePublished - Apr 2013

Fingerprint

Mitral Valve
Echocardiography
Tricuspid Valve Insufficiency
Marfan Syndrome
Tricuspid Valve
Mitral Valve Insufficiency
varespladib methyl

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery
  • Pulmonary and Respiratory Medicine

Cite this

Alfieri repair for post-repair mitral systolic anterior motion in a young child. / Khalpey, Zain I; Baird, Christopher W.; Myers, Patrick O.

In: Annals of Thoracic Surgery, Vol. 95, No. 4, 04.2013, p. 1452-1453.

Research output: Contribution to journalArticle

Khalpey, Zain I ; Baird, Christopher W. ; Myers, Patrick O. / Alfieri repair for post-repair mitral systolic anterior motion in a young child. In: Annals of Thoracic Surgery. 2013 ; Vol. 95, No. 4. pp. 1452-1453.
@article{67d898780cec4bb0b0db1062862ae75a,
title = "Alfieri repair for post-repair mitral systolic anterior motion in a young child",
abstract = "An 11-year-old patient with Marfan syndrome presented with severe mitral and tricuspid regurgitation and underwent mitral valve repair consisting of a vertical folding plasty of a redundant and prolapsing A1, closure of a deep cleft-like A1-A2 indentation, and annuloplasty to 28 mm, and tricuspid valve repair. Post-bypass echocardiography showed significant systolic anterior motion of the mitral valve. The annuloplasty was upsized to 34 mm and the A1 folding plasty taken down. Echocardiography showed persistent systolic anterior motion. An edge-to-edge repair was placed at A1-P1, eliminating all systolic anterior motion. The patient had an uneventful postoperative course and 6-week follow-up.",
author = "Khalpey, {Zain I} and Baird, {Christopher W.} and Myers, {Patrick O.}",
year = "2013",
month = "4",
doi = "10.1016/j.athoracsur.2012.09.017",
language = "English (US)",
volume = "95",
pages = "1452--1453",
journal = "Annals of Thoracic Surgery",
issn = "0003-4975",
publisher = "Elsevier USA",
number = "4",

}

TY - JOUR

T1 - Alfieri repair for post-repair mitral systolic anterior motion in a young child

AU - Khalpey, Zain I

AU - Baird, Christopher W.

AU - Myers, Patrick O.

PY - 2013/4

Y1 - 2013/4

N2 - An 11-year-old patient with Marfan syndrome presented with severe mitral and tricuspid regurgitation and underwent mitral valve repair consisting of a vertical folding plasty of a redundant and prolapsing A1, closure of a deep cleft-like A1-A2 indentation, and annuloplasty to 28 mm, and tricuspid valve repair. Post-bypass echocardiography showed significant systolic anterior motion of the mitral valve. The annuloplasty was upsized to 34 mm and the A1 folding plasty taken down. Echocardiography showed persistent systolic anterior motion. An edge-to-edge repair was placed at A1-P1, eliminating all systolic anterior motion. The patient had an uneventful postoperative course and 6-week follow-up.

AB - An 11-year-old patient with Marfan syndrome presented with severe mitral and tricuspid regurgitation and underwent mitral valve repair consisting of a vertical folding plasty of a redundant and prolapsing A1, closure of a deep cleft-like A1-A2 indentation, and annuloplasty to 28 mm, and tricuspid valve repair. Post-bypass echocardiography showed significant systolic anterior motion of the mitral valve. The annuloplasty was upsized to 34 mm and the A1 folding plasty taken down. Echocardiography showed persistent systolic anterior motion. An edge-to-edge repair was placed at A1-P1, eliminating all systolic anterior motion. The patient had an uneventful postoperative course and 6-week follow-up.

UR - http://www.scopus.com/inward/record.url?scp=84875297296&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875297296&partnerID=8YFLogxK

U2 - 10.1016/j.athoracsur.2012.09.017

DO - 10.1016/j.athoracsur.2012.09.017

M3 - Article

C2 - 23522214

AN - SCOPUS:84875297296

VL - 95

SP - 1452

EP - 1453

JO - Annals of Thoracic Surgery

JF - Annals of Thoracic Surgery

SN - 0003-4975

IS - 4

ER -