An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping

Mahesh Bharath Keerthivasan, Manojkumar Saranathan, Kevin Johnson, Zhiyang Fu, Craig C. Weinkauf, Diego R Martin, Ali Bilgin, Maria I Altbach

Research output: Contribution to journalArticle

Abstract

Purpose: To design a pulse sequence for efficient 3D T2-weighted imaging and T2 mapping. Methods: A stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles and a flexible pseudorandom view ordering is proposed for simultaneous T2-weighted imaging and T2 mapping. An analytical framework is introduced for the selection of refocusing flip angles to maximize relative tissue contrast while minimizing T2 estimation errors and maintaining low specific absorption rate. Images at different echo times are generated using a subspace constrained iterative reconstruction algorithm. T2 maps are obtained by modeling the signal evolution using the extended phase graph model. The technique is evaluated using phantoms and demonstrated in vivo for brain, knee, and carotid imaging. Results: Numerical simulations demonstrate an improved point spread function with the proposed pseudorandom view ordering compared to golden angle view ordering. Phantom experiments show that T2 values estimated from the stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles have good concordance with spin echo reference values. In vivo results show the proposed pulse sequence can generate qualitatively comparable T2-weighted images as conventional Cartesian 3D SPACE in addition to simultaneously generating 3D T2 maps. Conclusion: The proposed stack-of-stars turbo spin echo pulse sequence with pseudorandom view ordering and variable refocusing flip angles allows high resolution isotropic T2 mapping in clinically acceptable scan times. The optimization framework for the selection of refocusing flip angles improves T2 estimation accuracy while generating T2-weighted contrast comparable to conventional Cartesian imaging.

Original languageEnglish (US)
Pages (from-to)326-341
Number of pages16
JournalMagnetic Resonance in Medicine
Volume82
Issue number1
DOIs
StatePublished - Jul 1 2019

Fingerprint

Knee
Reference Values
Brain

Keywords

  • 3D T2 mapping
  • stack-of-stars
  • turbo spin echo
  • variable refocusing flip angles

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping. / Keerthivasan, Mahesh Bharath; Saranathan, Manojkumar; Johnson, Kevin; Fu, Zhiyang; Weinkauf, Craig C.; Martin, Diego R; Bilgin, Ali; Altbach, Maria I.

In: Magnetic Resonance in Medicine, Vol. 82, No. 1, 01.07.2019, p. 326-341.

Research output: Contribution to journalArticle

Keerthivasan, Mahesh Bharath ; Saranathan, Manojkumar ; Johnson, Kevin ; Fu, Zhiyang ; Weinkauf, Craig C. ; Martin, Diego R ; Bilgin, Ali ; Altbach, Maria I. / An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping. In: Magnetic Resonance in Medicine. 2019 ; Vol. 82, No. 1. pp. 326-341.
@article{6df9548c2f1247cdbe779904f63075f5,
title = "An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping",
abstract = "Purpose: To design a pulse sequence for efficient 3D T2-weighted imaging and T2 mapping. Methods: A stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles and a flexible pseudorandom view ordering is proposed for simultaneous T2-weighted imaging and T2 mapping. An analytical framework is introduced for the selection of refocusing flip angles to maximize relative tissue contrast while minimizing T2 estimation errors and maintaining low specific absorption rate. Images at different echo times are generated using a subspace constrained iterative reconstruction algorithm. T2 maps are obtained by modeling the signal evolution using the extended phase graph model. The technique is evaluated using phantoms and demonstrated in vivo for brain, knee, and carotid imaging. Results: Numerical simulations demonstrate an improved point spread function with the proposed pseudorandom view ordering compared to golden angle view ordering. Phantom experiments show that T2 values estimated from the stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles have good concordance with spin echo reference values. In vivo results show the proposed pulse sequence can generate qualitatively comparable T2-weighted images as conventional Cartesian 3D SPACE in addition to simultaneously generating 3D T2 maps. Conclusion: The proposed stack-of-stars turbo spin echo pulse sequence with pseudorandom view ordering and variable refocusing flip angles allows high resolution isotropic T2 mapping in clinically acceptable scan times. The optimization framework for the selection of refocusing flip angles improves T2 estimation accuracy while generating T2-weighted contrast comparable to conventional Cartesian imaging.",
keywords = "3D T2 mapping, stack-of-stars, turbo spin echo, variable refocusing flip angles",
author = "Keerthivasan, {Mahesh Bharath} and Manojkumar Saranathan and Kevin Johnson and Zhiyang Fu and Weinkauf, {Craig C.} and Martin, {Diego R} and Ali Bilgin and Altbach, {Maria I}",
year = "2019",
month = "7",
day = "1",
doi = "10.1002/mrm.27737",
language = "English (US)",
volume = "82",
pages = "326--341",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping

AU - Keerthivasan, Mahesh Bharath

AU - Saranathan, Manojkumar

AU - Johnson, Kevin

AU - Fu, Zhiyang

AU - Weinkauf, Craig C.

AU - Martin, Diego R

AU - Bilgin, Ali

AU - Altbach, Maria I

PY - 2019/7/1

Y1 - 2019/7/1

N2 - Purpose: To design a pulse sequence for efficient 3D T2-weighted imaging and T2 mapping. Methods: A stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles and a flexible pseudorandom view ordering is proposed for simultaneous T2-weighted imaging and T2 mapping. An analytical framework is introduced for the selection of refocusing flip angles to maximize relative tissue contrast while minimizing T2 estimation errors and maintaining low specific absorption rate. Images at different echo times are generated using a subspace constrained iterative reconstruction algorithm. T2 maps are obtained by modeling the signal evolution using the extended phase graph model. The technique is evaluated using phantoms and demonstrated in vivo for brain, knee, and carotid imaging. Results: Numerical simulations demonstrate an improved point spread function with the proposed pseudorandom view ordering compared to golden angle view ordering. Phantom experiments show that T2 values estimated from the stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles have good concordance with spin echo reference values. In vivo results show the proposed pulse sequence can generate qualitatively comparable T2-weighted images as conventional Cartesian 3D SPACE in addition to simultaneously generating 3D T2 maps. Conclusion: The proposed stack-of-stars turbo spin echo pulse sequence with pseudorandom view ordering and variable refocusing flip angles allows high resolution isotropic T2 mapping in clinically acceptable scan times. The optimization framework for the selection of refocusing flip angles improves T2 estimation accuracy while generating T2-weighted contrast comparable to conventional Cartesian imaging.

AB - Purpose: To design a pulse sequence for efficient 3D T2-weighted imaging and T2 mapping. Methods: A stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles and a flexible pseudorandom view ordering is proposed for simultaneous T2-weighted imaging and T2 mapping. An analytical framework is introduced for the selection of refocusing flip angles to maximize relative tissue contrast while minimizing T2 estimation errors and maintaining low specific absorption rate. Images at different echo times are generated using a subspace constrained iterative reconstruction algorithm. T2 maps are obtained by modeling the signal evolution using the extended phase graph model. The technique is evaluated using phantoms and demonstrated in vivo for brain, knee, and carotid imaging. Results: Numerical simulations demonstrate an improved point spread function with the proposed pseudorandom view ordering compared to golden angle view ordering. Phantom experiments show that T2 values estimated from the stack-of-stars turbo spin echo pulse sequence with variable refocusing flip angles have good concordance with spin echo reference values. In vivo results show the proposed pulse sequence can generate qualitatively comparable T2-weighted images as conventional Cartesian 3D SPACE in addition to simultaneously generating 3D T2 maps. Conclusion: The proposed stack-of-stars turbo spin echo pulse sequence with pseudorandom view ordering and variable refocusing flip angles allows high resolution isotropic T2 mapping in clinically acceptable scan times. The optimization framework for the selection of refocusing flip angles improves T2 estimation accuracy while generating T2-weighted contrast comparable to conventional Cartesian imaging.

KW - 3D T2 mapping

KW - stack-of-stars

KW - turbo spin echo

KW - variable refocusing flip angles

UR - http://www.scopus.com/inward/record.url?scp=85065040037&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065040037&partnerID=8YFLogxK

U2 - 10.1002/mrm.27737

DO - 10.1002/mrm.27737

M3 - Article

C2 - 30883879

AN - SCOPUS:85065040037

VL - 82

SP - 326

EP - 341

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -