An introduction to understanding elevation-based topography: How elevation data are displayed - A review

Michael W Belin, Stephen S. Khachikian

Research output: Contribution to journalArticle

91 Citations (Scopus)

Abstract

The increased frequency of refractive surgery and the shift towards the correction of higher-order aberrations necessitates a more detailed understanding of corneal shape. Early topography systems were based on Placido technology, as this was initially more intuitive for the general refractive surgeon. Newer computerized corneal modelling has increased our knowledge beyond what was previously possible. Elevation-based systems utilize a direct triangulation technique to measure the corneal surface. Elevation-based Scheimpflug imaging has advantages in that it allows for the measurement of both the anterior and posterior corneal surfaces. Posterior measurements are often the first indicators of future ectatic disease, in spite of completely normal anterior curvature. Examination of the posterior corneal surface can often reveal pathology that would otherwise be missed if one was relying on anterior analysis alone. Although there is little disagreement in diagnosing clinically evident keratoconus, agreement on what constitutes 'form fruste' or preclinical keratoconus remains elusive. The ability of elevation-based topography to analyse both anterior and posterior corneal surfaces adds significantly to our ability to identify eyes believed to be 'at risk'. As more knowledge is gained, it is appreciated that a full understanding of the workings of the human eye requires knowledge obtained from more than just one surface.

Original languageEnglish (US)
Pages (from-to)14-29
Number of pages16
JournalClinical and Experimental Ophthalmology
Volume37
Issue number1
DOIs
StatePublished - 2009
Externally publishedYes

Fingerprint

Keratoconus
Refractive Surgical Procedures
Pathology
Technology
Surgeons

Keywords

  • Corneal topography
  • Ectasia
  • Keratoconus

ASJC Scopus subject areas

  • Ophthalmology

Cite this

An introduction to understanding elevation-based topography : How elevation data are displayed - A review. / Belin, Michael W; Khachikian, Stephen S.

In: Clinical and Experimental Ophthalmology, Vol. 37, No. 1, 2009, p. 14-29.

Research output: Contribution to journalArticle

@article{11f0c949c4be459489ca44e7c00b9f69,
title = "An introduction to understanding elevation-based topography: How elevation data are displayed - A review",
abstract = "The increased frequency of refractive surgery and the shift towards the correction of higher-order aberrations necessitates a more detailed understanding of corneal shape. Early topography systems were based on Placido technology, as this was initially more intuitive for the general refractive surgeon. Newer computerized corneal modelling has increased our knowledge beyond what was previously possible. Elevation-based systems utilize a direct triangulation technique to measure the corneal surface. Elevation-based Scheimpflug imaging has advantages in that it allows for the measurement of both the anterior and posterior corneal surfaces. Posterior measurements are often the first indicators of future ectatic disease, in spite of completely normal anterior curvature. Examination of the posterior corneal surface can often reveal pathology that would otherwise be missed if one was relying on anterior analysis alone. Although there is little disagreement in diagnosing clinically evident keratoconus, agreement on what constitutes 'form fruste' or preclinical keratoconus remains elusive. The ability of elevation-based topography to analyse both anterior and posterior corneal surfaces adds significantly to our ability to identify eyes believed to be 'at risk'. As more knowledge is gained, it is appreciated that a full understanding of the workings of the human eye requires knowledge obtained from more than just one surface.",
keywords = "Corneal topography, Ectasia, Keratoconus",
author = "Belin, {Michael W} and Khachikian, {Stephen S.}",
year = "2009",
doi = "10.1111/j.1442-9071.2008.01821.x",
language = "English (US)",
volume = "37",
pages = "14--29",
journal = "Clinical and Experimental Ophthalmology",
issn = "1442-6404",
publisher = "Wiley-Blackwell",
number = "1",

}

TY - JOUR

T1 - An introduction to understanding elevation-based topography

T2 - How elevation data are displayed - A review

AU - Belin, Michael W

AU - Khachikian, Stephen S.

PY - 2009

Y1 - 2009

N2 - The increased frequency of refractive surgery and the shift towards the correction of higher-order aberrations necessitates a more detailed understanding of corneal shape. Early topography systems were based on Placido technology, as this was initially more intuitive for the general refractive surgeon. Newer computerized corneal modelling has increased our knowledge beyond what was previously possible. Elevation-based systems utilize a direct triangulation technique to measure the corneal surface. Elevation-based Scheimpflug imaging has advantages in that it allows for the measurement of both the anterior and posterior corneal surfaces. Posterior measurements are often the first indicators of future ectatic disease, in spite of completely normal anterior curvature. Examination of the posterior corneal surface can often reveal pathology that would otherwise be missed if one was relying on anterior analysis alone. Although there is little disagreement in diagnosing clinically evident keratoconus, agreement on what constitutes 'form fruste' or preclinical keratoconus remains elusive. The ability of elevation-based topography to analyse both anterior and posterior corneal surfaces adds significantly to our ability to identify eyes believed to be 'at risk'. As more knowledge is gained, it is appreciated that a full understanding of the workings of the human eye requires knowledge obtained from more than just one surface.

AB - The increased frequency of refractive surgery and the shift towards the correction of higher-order aberrations necessitates a more detailed understanding of corneal shape. Early topography systems were based on Placido technology, as this was initially more intuitive for the general refractive surgeon. Newer computerized corneal modelling has increased our knowledge beyond what was previously possible. Elevation-based systems utilize a direct triangulation technique to measure the corneal surface. Elevation-based Scheimpflug imaging has advantages in that it allows for the measurement of both the anterior and posterior corneal surfaces. Posterior measurements are often the first indicators of future ectatic disease, in spite of completely normal anterior curvature. Examination of the posterior corneal surface can often reveal pathology that would otherwise be missed if one was relying on anterior analysis alone. Although there is little disagreement in diagnosing clinically evident keratoconus, agreement on what constitutes 'form fruste' or preclinical keratoconus remains elusive. The ability of elevation-based topography to analyse both anterior and posterior corneal surfaces adds significantly to our ability to identify eyes believed to be 'at risk'. As more knowledge is gained, it is appreciated that a full understanding of the workings of the human eye requires knowledge obtained from more than just one surface.

KW - Corneal topography

KW - Ectasia

KW - Keratoconus

UR - http://www.scopus.com/inward/record.url?scp=63649104023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=63649104023&partnerID=8YFLogxK

U2 - 10.1111/j.1442-9071.2008.01821.x

DO - 10.1111/j.1442-9071.2008.01821.x

M3 - Article

C2 - 19016811

AN - SCOPUS:63649104023

VL - 37

SP - 14

EP - 29

JO - Clinical and Experimental Ophthalmology

JF - Clinical and Experimental Ophthalmology

SN - 1442-6404