Analysis of static and time-varying polarization errors in the multiangle spectropolarimetric imager

Anna Britt Mahler, David J. Diner, Russell A Chipman

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Multiangle Spectropolarimetric Imager (MSPI) sensitivity to static and time-varying polarization errors is examined. For a system without noise, static polarization errors are accurately represented by the calibration coefficients, and therefore do not impede correct mapping of measured to input Stokes vectors. But noise is invariably introduced during the detection process, and static polarization errors reduce the system's signal-to-noise ratio (SNR) by increasing noise sensitivity. Noise sensitivity is minimized by minimizing the condition number of the system data reduction matrix [Appl. Opt. 41, 619 (2002)]. The sensitivity of condition numbers to static polarization errors is presented. The condition number of the nominal MSPI data reduction matrix is approximately 1.1 or less for all fields. The increase in the condition number above 1 results primarily from a quarter wave plate and mirror coating retardance magnitude errors. Sensitivity of the degree of linear polarization (DoLP) error with respect to timevarying diattenuation and retardance error was used to set a time-varying diattenuation magnitude tolerance of 0.005 and a time-varying retardance magnitude tolerance of ± 0:2°. A Monte Carlo simulation of the calibration and measurements using anticipated static and time-varying errors indicates that MSPI has a probability of 0.9 of meeting its 0.005 DoLP uncertainty requirement.

Original languageEnglish (US)
Pages (from-to)2080-2087
Number of pages8
JournalApplied Optics
Volume50
Issue number14
DOIs
StatePublished - May 10 2011

Fingerprint

Image sensors
Polarization
polarization
data reduction
linear polarization
sensitivity
Data reduction
Calibration
matrices
Signal to noise ratio
Mirrors
signal to noise ratios
mirrors
coatings
Coatings
requirements
coefficients

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Analysis of static and time-varying polarization errors in the multiangle spectropolarimetric imager. / Mahler, Anna Britt; Diner, David J.; Chipman, Russell A.

In: Applied Optics, Vol. 50, No. 14, 10.05.2011, p. 2080-2087.

Research output: Contribution to journalArticle

@article{9af8a41a358544e18463c56fc4c2281d,
title = "Analysis of static and time-varying polarization errors in the multiangle spectropolarimetric imager",
abstract = "Multiangle Spectropolarimetric Imager (MSPI) sensitivity to static and time-varying polarization errors is examined. For a system without noise, static polarization errors are accurately represented by the calibration coefficients, and therefore do not impede correct mapping of measured to input Stokes vectors. But noise is invariably introduced during the detection process, and static polarization errors reduce the system's signal-to-noise ratio (SNR) by increasing noise sensitivity. Noise sensitivity is minimized by minimizing the condition number of the system data reduction matrix [Appl. Opt. 41, 619 (2002)]. The sensitivity of condition numbers to static polarization errors is presented. The condition number of the nominal MSPI data reduction matrix is approximately 1.1 or less for all fields. The increase in the condition number above 1 results primarily from a quarter wave plate and mirror coating retardance magnitude errors. Sensitivity of the degree of linear polarization (DoLP) error with respect to timevarying diattenuation and retardance error was used to set a time-varying diattenuation magnitude tolerance of 0.005 and a time-varying retardance magnitude tolerance of ± 0:2°. A Monte Carlo simulation of the calibration and measurements using anticipated static and time-varying errors indicates that MSPI has a probability of 0.9 of meeting its 0.005 DoLP uncertainty requirement.",
author = "Mahler, {Anna Britt} and Diner, {David J.} and Chipman, {Russell A}",
year = "2011",
month = "5",
day = "10",
doi = "10.1364/AO.50.002080",
language = "English (US)",
volume = "50",
pages = "2080--2087",
journal = "Applied Optics",
issn = "1559-128X",
publisher = "The Optical Society",
number = "14",

}

TY - JOUR

T1 - Analysis of static and time-varying polarization errors in the multiangle spectropolarimetric imager

AU - Mahler, Anna Britt

AU - Diner, David J.

AU - Chipman, Russell A

PY - 2011/5/10

Y1 - 2011/5/10

N2 - Multiangle Spectropolarimetric Imager (MSPI) sensitivity to static and time-varying polarization errors is examined. For a system without noise, static polarization errors are accurately represented by the calibration coefficients, and therefore do not impede correct mapping of measured to input Stokes vectors. But noise is invariably introduced during the detection process, and static polarization errors reduce the system's signal-to-noise ratio (SNR) by increasing noise sensitivity. Noise sensitivity is minimized by minimizing the condition number of the system data reduction matrix [Appl. Opt. 41, 619 (2002)]. The sensitivity of condition numbers to static polarization errors is presented. The condition number of the nominal MSPI data reduction matrix is approximately 1.1 or less for all fields. The increase in the condition number above 1 results primarily from a quarter wave plate and mirror coating retardance magnitude errors. Sensitivity of the degree of linear polarization (DoLP) error with respect to timevarying diattenuation and retardance error was used to set a time-varying diattenuation magnitude tolerance of 0.005 and a time-varying retardance magnitude tolerance of ± 0:2°. A Monte Carlo simulation of the calibration and measurements using anticipated static and time-varying errors indicates that MSPI has a probability of 0.9 of meeting its 0.005 DoLP uncertainty requirement.

AB - Multiangle Spectropolarimetric Imager (MSPI) sensitivity to static and time-varying polarization errors is examined. For a system without noise, static polarization errors are accurately represented by the calibration coefficients, and therefore do not impede correct mapping of measured to input Stokes vectors. But noise is invariably introduced during the detection process, and static polarization errors reduce the system's signal-to-noise ratio (SNR) by increasing noise sensitivity. Noise sensitivity is minimized by minimizing the condition number of the system data reduction matrix [Appl. Opt. 41, 619 (2002)]. The sensitivity of condition numbers to static polarization errors is presented. The condition number of the nominal MSPI data reduction matrix is approximately 1.1 or less for all fields. The increase in the condition number above 1 results primarily from a quarter wave plate and mirror coating retardance magnitude errors. Sensitivity of the degree of linear polarization (DoLP) error with respect to timevarying diattenuation and retardance error was used to set a time-varying diattenuation magnitude tolerance of 0.005 and a time-varying retardance magnitude tolerance of ± 0:2°. A Monte Carlo simulation of the calibration and measurements using anticipated static and time-varying errors indicates that MSPI has a probability of 0.9 of meeting its 0.005 DoLP uncertainty requirement.

UR - http://www.scopus.com/inward/record.url?scp=79958708061&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79958708061&partnerID=8YFLogxK

U2 - 10.1364/AO.50.002080

DO - 10.1364/AO.50.002080

M3 - Article

C2 - 21556109

AN - SCOPUS:79958708061

VL - 50

SP - 2080

EP - 2087

JO - Applied Optics

JF - Applied Optics

SN - 1559-128X

IS - 14

ER -