Abstract

The heat transfer within a perfused tissue in the presence of a vessel is considered. The bio-heat transfer equation is used for the perfused tissue and a lumped capacitance analysis is used for the convection in the vessel with a constant Nusselt number. Analytical solutions are obtained for two cases: (i) the arterial temperature of the perfused blood in the bio-heat transfer equation is equal to the axially varying mixed mean temperature of the blood in the vessel and, (ii) that arterial temperature is assumed to be constant. Dimensionless equilibrium length and temperature expressions are obtained and presented.

Original languageEnglish (US)
Pages (from-to)208-212
Number of pages5
JournalJournal of Biomechanical Engineering
Volume116
Issue number2
StatePublished - May 1994

Fingerprint

Blood vessels
Blood Vessels
Hot Temperature
Heat transfer
Temperature
Blood
Tissue
Convection
Nusselt number
Capacitance

ASJC Scopus subject areas

  • Biophysics
  • Biomedical Engineering

Cite this

Analytical solutions of Pennes bio-heat transfer equation with a blood vessel. / Huang, H. W.; Chan, Cholik; Roemer, R. B.

In: Journal of Biomechanical Engineering, Vol. 116, No. 2, 05.1994, p. 208-212.

Research output: Contribution to journalArticle

@article{a93d4f87c2ad489e8250a60b4a39b1cb,
title = "Analytical solutions of Pennes bio-heat transfer equation with a blood vessel",
abstract = "The heat transfer within a perfused tissue in the presence of a vessel is considered. The bio-heat transfer equation is used for the perfused tissue and a lumped capacitance analysis is used for the convection in the vessel with a constant Nusselt number. Analytical solutions are obtained for two cases: (i) the arterial temperature of the perfused blood in the bio-heat transfer equation is equal to the axially varying mixed mean temperature of the blood in the vessel and, (ii) that arterial temperature is assumed to be constant. Dimensionless equilibrium length and temperature expressions are obtained and presented.",
author = "Huang, {H. W.} and Cholik Chan and Roemer, {R. B.}",
year = "1994",
month = "5",
language = "English (US)",
volume = "116",
pages = "208--212",
journal = "Journal of Biomechanical Engineering",
issn = "0148-0731",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "2",

}

TY - JOUR

T1 - Analytical solutions of Pennes bio-heat transfer equation with a blood vessel

AU - Huang, H. W.

AU - Chan, Cholik

AU - Roemer, R. B.

PY - 1994/5

Y1 - 1994/5

N2 - The heat transfer within a perfused tissue in the presence of a vessel is considered. The bio-heat transfer equation is used for the perfused tissue and a lumped capacitance analysis is used for the convection in the vessel with a constant Nusselt number. Analytical solutions are obtained for two cases: (i) the arterial temperature of the perfused blood in the bio-heat transfer equation is equal to the axially varying mixed mean temperature of the blood in the vessel and, (ii) that arterial temperature is assumed to be constant. Dimensionless equilibrium length and temperature expressions are obtained and presented.

AB - The heat transfer within a perfused tissue in the presence of a vessel is considered. The bio-heat transfer equation is used for the perfused tissue and a lumped capacitance analysis is used for the convection in the vessel with a constant Nusselt number. Analytical solutions are obtained for two cases: (i) the arterial temperature of the perfused blood in the bio-heat transfer equation is equal to the axially varying mixed mean temperature of the blood in the vessel and, (ii) that arterial temperature is assumed to be constant. Dimensionless equilibrium length and temperature expressions are obtained and presented.

UR - http://www.scopus.com/inward/record.url?scp=0028439376&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028439376&partnerID=8YFLogxK

M3 - Article

C2 - 8078328

AN - SCOPUS:0028439376

VL - 116

SP - 208

EP - 212

JO - Journal of Biomechanical Engineering

JF - Journal of Biomechanical Engineering