Application of a Line Laser Scanner for Bed Form Tracking in a Laboratory Flume

T. V. de Ruijsscher, A. J.F. Hoitink, S. Dinnissen, B. Vermeulen, P. Hazenberg

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

A new measurement method for continuous detection of bed forms in movable bed laboratory experiments is presented and tested. The device consists of a line laser coupled to a 3-D camera, which makes use of triangulation. This allows to measure bed forms during morphodynamic experiments, without removing the water from the flume. A correction is applied for the effect of laser refraction at the air-water interface. We conclude that the absolute measurement error increases with increasing flow velocity, its standard deviation increases with water depth and flow velocity, and the percentage of missing values increases with water depth. Although 71% of the data is lost in a pilot moving bed experiment with sand, still high agreement between flowing water and dry bed measurements is found when a robust LOcally weighted regrESSion (LOESS) procedure is applied. This is promising for bed form tracking applications in laboratory experiments, especially when lightweight sediments like polystyrene are used, which require smaller flow velocities to achieve dynamic similarity to the prototype. This is confirmed in a moving bed experiment with polystyrene.

Original languageEnglish (US)
Pages (from-to)2078-2094
Number of pages17
JournalWater Resources Research
Volume54
Issue number3
DOIs
StatePublished - Mar 2018
Externally publishedYes

Fingerprint

bedform
scanner
flow velocity
laser
water depth
experiment
triangulation
morphodynamics
measurement method
refraction
water flow
water
sand
air
sediment
laboratory
laboratory experiment

Keywords

  • bed level monitoring
  • dune tracking
  • line laser scanner
  • LOESS
  • physical scale model

ASJC Scopus subject areas

  • Water Science and Technology

Cite this

Application of a Line Laser Scanner for Bed Form Tracking in a Laboratory Flume. / de Ruijsscher, T. V.; Hoitink, A. J.F.; Dinnissen, S.; Vermeulen, B.; Hazenberg, P.

In: Water Resources Research, Vol. 54, No. 3, 03.2018, p. 2078-2094.

Research output: Contribution to journalArticle

de Ruijsscher, TV, Hoitink, AJF, Dinnissen, S, Vermeulen, B & Hazenberg, P 2018, 'Application of a Line Laser Scanner for Bed Form Tracking in a Laboratory Flume', Water Resources Research, vol. 54, no. 3, pp. 2078-2094. https://doi.org/10.1002/2017WR021646
de Ruijsscher, T. V. ; Hoitink, A. J.F. ; Dinnissen, S. ; Vermeulen, B. ; Hazenberg, P. / Application of a Line Laser Scanner for Bed Form Tracking in a Laboratory Flume. In: Water Resources Research. 2018 ; Vol. 54, No. 3. pp. 2078-2094.
@article{6e29b4e1f8d748fbbd7e69635e94af7a,
title = "Application of a Line Laser Scanner for Bed Form Tracking in a Laboratory Flume",
abstract = "A new measurement method for continuous detection of bed forms in movable bed laboratory experiments is presented and tested. The device consists of a line laser coupled to a 3-D camera, which makes use of triangulation. This allows to measure bed forms during morphodynamic experiments, without removing the water from the flume. A correction is applied for the effect of laser refraction at the air-water interface. We conclude that the absolute measurement error increases with increasing flow velocity, its standard deviation increases with water depth and flow velocity, and the percentage of missing values increases with water depth. Although 71{\%} of the data is lost in a pilot moving bed experiment with sand, still high agreement between flowing water and dry bed measurements is found when a robust LOcally weighted regrESSion (LOESS) procedure is applied. This is promising for bed form tracking applications in laboratory experiments, especially when lightweight sediments like polystyrene are used, which require smaller flow velocities to achieve dynamic similarity to the prototype. This is confirmed in a moving bed experiment with polystyrene.",
keywords = "bed level monitoring, dune tracking, line laser scanner, LOESS, physical scale model",
author = "{de Ruijsscher}, {T. V.} and Hoitink, {A. J.F.} and S. Dinnissen and B. Vermeulen and P. Hazenberg",
year = "2018",
month = "3",
doi = "10.1002/2017WR021646",
language = "English (US)",
volume = "54",
pages = "2078--2094",
journal = "Water Resources Research",
issn = "0043-1397",
publisher = "American Geophysical Union",
number = "3",

}

TY - JOUR

T1 - Application of a Line Laser Scanner for Bed Form Tracking in a Laboratory Flume

AU - de Ruijsscher, T. V.

AU - Hoitink, A. J.F.

AU - Dinnissen, S.

AU - Vermeulen, B.

AU - Hazenberg, P.

PY - 2018/3

Y1 - 2018/3

N2 - A new measurement method for continuous detection of bed forms in movable bed laboratory experiments is presented and tested. The device consists of a line laser coupled to a 3-D camera, which makes use of triangulation. This allows to measure bed forms during morphodynamic experiments, without removing the water from the flume. A correction is applied for the effect of laser refraction at the air-water interface. We conclude that the absolute measurement error increases with increasing flow velocity, its standard deviation increases with water depth and flow velocity, and the percentage of missing values increases with water depth. Although 71% of the data is lost in a pilot moving bed experiment with sand, still high agreement between flowing water and dry bed measurements is found when a robust LOcally weighted regrESSion (LOESS) procedure is applied. This is promising for bed form tracking applications in laboratory experiments, especially when lightweight sediments like polystyrene are used, which require smaller flow velocities to achieve dynamic similarity to the prototype. This is confirmed in a moving bed experiment with polystyrene.

AB - A new measurement method for continuous detection of bed forms in movable bed laboratory experiments is presented and tested. The device consists of a line laser coupled to a 3-D camera, which makes use of triangulation. This allows to measure bed forms during morphodynamic experiments, without removing the water from the flume. A correction is applied for the effect of laser refraction at the air-water interface. We conclude that the absolute measurement error increases with increasing flow velocity, its standard deviation increases with water depth and flow velocity, and the percentage of missing values increases with water depth. Although 71% of the data is lost in a pilot moving bed experiment with sand, still high agreement between flowing water and dry bed measurements is found when a robust LOcally weighted regrESSion (LOESS) procedure is applied. This is promising for bed form tracking applications in laboratory experiments, especially when lightweight sediments like polystyrene are used, which require smaller flow velocities to achieve dynamic similarity to the prototype. This is confirmed in a moving bed experiment with polystyrene.

KW - bed level monitoring

KW - dune tracking

KW - line laser scanner

KW - LOESS

KW - physical scale model

UR - http://www.scopus.com/inward/record.url?scp=85044211170&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044211170&partnerID=8YFLogxK

U2 - 10.1002/2017WR021646

DO - 10.1002/2017WR021646

M3 - Article

AN - SCOPUS:85044211170

VL - 54

SP - 2078

EP - 2094

JO - Water Resources Research

JF - Water Resources Research

SN - 0043-1397

IS - 3

ER -