Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery

John M. Lee, Jayakar V. Nayak, Laurie L. Doghramji, Kevin C. Welch, Alexander G Chiu

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

Background: Saline nasal irrigation has become an important aspect of post-operative care following endoscopic sinus surgery. The objective of this study was to identify the risks of contamination of both the nasal irrigation bottle and fluid following endoscopic sinus surgery. Methods: This was a prospective study of consecutive patients undergoing endoscopic sinus surgery for chronic sinusitis. All patients were given nasal irrigation bottles with detailed cleaning instructions preoperatively. Nasal irrigation bottles were collected and cultured at 1 and 2 weeks postoperatively. During the same visit, 5-ml of sterile normal saline was mixed into the irrigation bottle and then cultured separately. Results: A total of 20 patients agreed to participate in the study. At 1 week postoperatively, 50% of the bottles had positive cultures with 40% of the irrigation samples testing positive for bacteria. At two weeks, the contamination in the irrigation bottle and fluid decreased to 26.7% and 20%, respectively. The most common bacteria cultured was Pseudomonas aeruginosa. There were no cases of postoperative infection. Conclusion: Despite detailed cleaning instructions, there is a relatively high risk of bacterial contamination in nasal irrigation bottles and fluid following endoscopic sinus surgery. Although these risks did not translate into higher infection rates postsurgery, it may be important for physicians to emphasize regular cleaning techniques to minimize a potential source of bacterial contaminant exposure.

Original languageEnglish (US)
Pages (from-to)197-199
Number of pages3
JournalAmerican Journal of Rhinology and Allergy
Volume24
Issue number3
DOIs
StatePublished - May 2010
Externally publishedYes

Fingerprint

Nasal Lavage
Bacteria
Sinusitis
Infection
Pseudomonas aeruginosa
Prospective Studies
Physicians

Keywords

  • Chronic sinusitis
  • Cleaning
  • Contamination
  • Endoscopic sinus surgery
  • Irrigation bottle
  • Postoperative care
  • Saline nasal irrigation

ASJC Scopus subject areas

  • Otorhinolaryngology
  • Immunology and Allergy

Cite this

Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery. / Lee, John M.; Nayak, Jayakar V.; Doghramji, Laurie L.; Welch, Kevin C.; Chiu, Alexander G.

In: American Journal of Rhinology and Allergy, Vol. 24, No. 3, 05.2010, p. 197-199.

Research output: Contribution to journalArticle

Lee, John M. ; Nayak, Jayakar V. ; Doghramji, Laurie L. ; Welch, Kevin C. ; Chiu, Alexander G. / Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery. In: American Journal of Rhinology and Allergy. 2010 ; Vol. 24, No. 3. pp. 197-199.
@article{9c65012af8154d248f691f527f0043d4,
title = "Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery",
abstract = "Background: Saline nasal irrigation has become an important aspect of post-operative care following endoscopic sinus surgery. The objective of this study was to identify the risks of contamination of both the nasal irrigation bottle and fluid following endoscopic sinus surgery. Methods: This was a prospective study of consecutive patients undergoing endoscopic sinus surgery for chronic sinusitis. All patients were given nasal irrigation bottles with detailed cleaning instructions preoperatively. Nasal irrigation bottles were collected and cultured at 1 and 2 weeks postoperatively. During the same visit, 5-ml of sterile normal saline was mixed into the irrigation bottle and then cultured separately. Results: A total of 20 patients agreed to participate in the study. At 1 week postoperatively, 50{\%} of the bottles had positive cultures with 40{\%} of the irrigation samples testing positive for bacteria. At two weeks, the contamination in the irrigation bottle and fluid decreased to 26.7{\%} and 20{\%}, respectively. The most common bacteria cultured was Pseudomonas aeruginosa. There were no cases of postoperative infection. Conclusion: Despite detailed cleaning instructions, there is a relatively high risk of bacterial contamination in nasal irrigation bottles and fluid following endoscopic sinus surgery. Although these risks did not translate into higher infection rates postsurgery, it may be important for physicians to emphasize regular cleaning techniques to minimize a potential source of bacterial contaminant exposure.",
keywords = "Chronic sinusitis, Cleaning, Contamination, Endoscopic sinus surgery, Irrigation bottle, Postoperative care, Saline nasal irrigation",
author = "Lee, {John M.} and Nayak, {Jayakar V.} and Doghramji, {Laurie L.} and Welch, {Kevin C.} and Chiu, {Alexander G}",
year = "2010",
month = "5",
doi = "10.2500/ajra.2010.24.3481",
language = "English (US)",
volume = "24",
pages = "197--199",
journal = "American Journal of Rhinology and Allergy",
issn = "1945-8924",
publisher = "OceanSide Publications Inc.",
number = "3",

}

TY - JOUR

T1 - Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery

AU - Lee, John M.

AU - Nayak, Jayakar V.

AU - Doghramji, Laurie L.

AU - Welch, Kevin C.

AU - Chiu, Alexander G

PY - 2010/5

Y1 - 2010/5

N2 - Background: Saline nasal irrigation has become an important aspect of post-operative care following endoscopic sinus surgery. The objective of this study was to identify the risks of contamination of both the nasal irrigation bottle and fluid following endoscopic sinus surgery. Methods: This was a prospective study of consecutive patients undergoing endoscopic sinus surgery for chronic sinusitis. All patients were given nasal irrigation bottles with detailed cleaning instructions preoperatively. Nasal irrigation bottles were collected and cultured at 1 and 2 weeks postoperatively. During the same visit, 5-ml of sterile normal saline was mixed into the irrigation bottle and then cultured separately. Results: A total of 20 patients agreed to participate in the study. At 1 week postoperatively, 50% of the bottles had positive cultures with 40% of the irrigation samples testing positive for bacteria. At two weeks, the contamination in the irrigation bottle and fluid decreased to 26.7% and 20%, respectively. The most common bacteria cultured was Pseudomonas aeruginosa. There were no cases of postoperative infection. Conclusion: Despite detailed cleaning instructions, there is a relatively high risk of bacterial contamination in nasal irrigation bottles and fluid following endoscopic sinus surgery. Although these risks did not translate into higher infection rates postsurgery, it may be important for physicians to emphasize regular cleaning techniques to minimize a potential source of bacterial contaminant exposure.

AB - Background: Saline nasal irrigation has become an important aspect of post-operative care following endoscopic sinus surgery. The objective of this study was to identify the risks of contamination of both the nasal irrigation bottle and fluid following endoscopic sinus surgery. Methods: This was a prospective study of consecutive patients undergoing endoscopic sinus surgery for chronic sinusitis. All patients were given nasal irrigation bottles with detailed cleaning instructions preoperatively. Nasal irrigation bottles were collected and cultured at 1 and 2 weeks postoperatively. During the same visit, 5-ml of sterile normal saline was mixed into the irrigation bottle and then cultured separately. Results: A total of 20 patients agreed to participate in the study. At 1 week postoperatively, 50% of the bottles had positive cultures with 40% of the irrigation samples testing positive for bacteria. At two weeks, the contamination in the irrigation bottle and fluid decreased to 26.7% and 20%, respectively. The most common bacteria cultured was Pseudomonas aeruginosa. There were no cases of postoperative infection. Conclusion: Despite detailed cleaning instructions, there is a relatively high risk of bacterial contamination in nasal irrigation bottles and fluid following endoscopic sinus surgery. Although these risks did not translate into higher infection rates postsurgery, it may be important for physicians to emphasize regular cleaning techniques to minimize a potential source of bacterial contaminant exposure.

KW - Chronic sinusitis

KW - Cleaning

KW - Contamination

KW - Endoscopic sinus surgery

KW - Irrigation bottle

KW - Postoperative care

KW - Saline nasal irrigation

UR - http://www.scopus.com/inward/record.url?scp=77953636351&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953636351&partnerID=8YFLogxK

U2 - 10.2500/ajra.2010.24.3481

DO - 10.2500/ajra.2010.24.3481

M3 - Article

C2 - 20537286

AN - SCOPUS:77953636351

VL - 24

SP - 197

EP - 199

JO - American Journal of Rhinology and Allergy

JF - American Journal of Rhinology and Allergy

SN - 1945-8924

IS - 3

ER -