Assessment of grating acuity in infants and toddlers using an electronic acuity card

The Dobson Card

Kathleen M. Mohan, Joseph M Miller, Erin M Harvey, Kimberly D. Gerhart, Howard P. Apple, Deborah Apple, Jordana M. Smith, Amy L. Davis, Tina Leonard-Green, Irene Campus, Leslie K Dennis

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Purpose: To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Methods: Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Results: Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Conclusions: Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers.

Original languageEnglish (US)
Pages (from-to)56-59
Number of pages4
JournalJournal of Pediatric Ophthalmology and Strabismus
Volume53
Issue number1
DOIs
StatePublished - 2016

Fingerprint

Refractive Errors
Vision Screening
Visual Acuity
Mydriatics
Retinoscopy
Handheld Computers
Polymethyl Methacrylate
Tablets
Referral and Consultation
Research

ASJC Scopus subject areas

  • Ophthalmology
  • Pediatrics, Perinatology, and Child Health

Cite this

Assessment of grating acuity in infants and toddlers using an electronic acuity card : The Dobson Card. / Mohan, Kathleen M.; Miller, Joseph M; Harvey, Erin M; Gerhart, Kimberly D.; Apple, Howard P.; Apple, Deborah; Smith, Jordana M.; Davis, Amy L.; Leonard-Green, Tina; Campus, Irene; Dennis, Leslie K.

In: Journal of Pediatric Ophthalmology and Strabismus, Vol. 53, No. 1, 2016, p. 56-59.

Research output: Contribution to journalArticle

Mohan, Kathleen M. ; Miller, Joseph M ; Harvey, Erin M ; Gerhart, Kimberly D. ; Apple, Howard P. ; Apple, Deborah ; Smith, Jordana M. ; Davis, Amy L. ; Leonard-Green, Tina ; Campus, Irene ; Dennis, Leslie K. / Assessment of grating acuity in infants and toddlers using an electronic acuity card : The Dobson Card. In: Journal of Pediatric Ophthalmology and Strabismus. 2016 ; Vol. 53, No. 1. pp. 56-59.
@article{e494fa1301b14fe89aa8c0a036a88a55,
title = "Assessment of grating acuity in infants and toddlers using an electronic acuity card: The Dobson Card",
abstract = "Purpose: To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Methods: Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Results: Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Conclusions: Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers.",
author = "Mohan, {Kathleen M.} and Miller, {Joseph M} and Harvey, {Erin M} and Gerhart, {Kimberly D.} and Apple, {Howard P.} and Deborah Apple and Smith, {Jordana M.} and Davis, {Amy L.} and Tina Leonard-Green and Irene Campus and Dennis, {Leslie K}",
year = "2016",
doi = "10.3928/01913913-20160113-09",
language = "English (US)",
volume = "53",
pages = "56--59",
journal = "Journal of Pediatric Ophthalmology and Strabismus",
issn = "0191-3913",
publisher = "Slack Incorporated",
number = "1",

}

TY - JOUR

T1 - Assessment of grating acuity in infants and toddlers using an electronic acuity card

T2 - The Dobson Card

AU - Mohan, Kathleen M.

AU - Miller, Joseph M

AU - Harvey, Erin M

AU - Gerhart, Kimberly D.

AU - Apple, Howard P.

AU - Apple, Deborah

AU - Smith, Jordana M.

AU - Davis, Amy L.

AU - Leonard-Green, Tina

AU - Campus, Irene

AU - Dennis, Leslie K

PY - 2016

Y1 - 2016

N2 - Purpose: To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Methods: Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Results: Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Conclusions: Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers.

AB - Purpose: To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Methods: Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Results: Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Conclusions: Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers.

UR - http://www.scopus.com/inward/record.url?scp=84971574709&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84971574709&partnerID=8YFLogxK

U2 - 10.3928/01913913-20160113-09

DO - 10.3928/01913913-20160113-09

M3 - Article

VL - 53

SP - 56

EP - 59

JO - Journal of Pediatric Ophthalmology and Strabismus

JF - Journal of Pediatric Ophthalmology and Strabismus

SN - 0191-3913

IS - 1

ER -