Automated statistical approach to Langley evaluation for a solar radiometer

Michele A. Kuester, Kurtis J. Thome, John A Reagan

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

We present a statistical approach to Langley evaluation (SALE) leading to an improved method of calibration of an automated solar radiometer. Software was developed with the SALE method to first determine whether a day is a good calibration day and then to automatically calculate an intercept value for the solar radiometer. Results from manual processing of calibration data sets agree with those of the automated method to within the errors of each approach.

Original languageEnglish (US)
Pages (from-to)4914-4921
Number of pages8
JournalApplied Optics
Volume42
Issue number24
StatePublished - Aug 20 2003

Fingerprint

Radiometers
radiometers
Calibration
evaluation
computer programs
Processing

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Automated statistical approach to Langley evaluation for a solar radiometer. / Kuester, Michele A.; Thome, Kurtis J.; Reagan, John A.

In: Applied Optics, Vol. 42, No. 24, 20.08.2003, p. 4914-4921.

Research output: Contribution to journalArticle

Kuester, Michele A. ; Thome, Kurtis J. ; Reagan, John A. / Automated statistical approach to Langley evaluation for a solar radiometer. In: Applied Optics. 2003 ; Vol. 42, No. 24. pp. 4914-4921.
@article{ba79a5b00f584ec5acdb943608bb915b,
title = "Automated statistical approach to Langley evaluation for a solar radiometer",
abstract = "We present a statistical approach to Langley evaluation (SALE) leading to an improved method of calibration of an automated solar radiometer. Software was developed with the SALE method to first determine whether a day is a good calibration day and then to automatically calculate an intercept value for the solar radiometer. Results from manual processing of calibration data sets agree with those of the automated method to within the errors of each approach.",
author = "Kuester, {Michele A.} and Thome, {Kurtis J.} and Reagan, {John A}",
year = "2003",
month = "8",
day = "20",
language = "English (US)",
volume = "42",
pages = "4914--4921",
journal = "Applied Optics",
issn = "1559-128X",
publisher = "The Optical Society",
number = "24",

}

TY - JOUR

T1 - Automated statistical approach to Langley evaluation for a solar radiometer

AU - Kuester, Michele A.

AU - Thome, Kurtis J.

AU - Reagan, John A

PY - 2003/8/20

Y1 - 2003/8/20

N2 - We present a statistical approach to Langley evaluation (SALE) leading to an improved method of calibration of an automated solar radiometer. Software was developed with the SALE method to first determine whether a day is a good calibration day and then to automatically calculate an intercept value for the solar radiometer. Results from manual processing of calibration data sets agree with those of the automated method to within the errors of each approach.

AB - We present a statistical approach to Langley evaluation (SALE) leading to an improved method of calibration of an automated solar radiometer. Software was developed with the SALE method to first determine whether a day is a good calibration day and then to automatically calculate an intercept value for the solar radiometer. Results from manual processing of calibration data sets agree with those of the automated method to within the errors of each approach.

UR - http://www.scopus.com/inward/record.url?scp=0042286958&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0042286958&partnerID=8YFLogxK

M3 - Article

C2 - 12952339

AN - SCOPUS:0042286958

VL - 42

SP - 4914

EP - 4921

JO - Applied Optics

JF - Applied Optics

SN - 1559-128X

IS - 24

ER -