Barcodes for DNA sequencing with guaranteed error correction capability

A. R. Krishnan, M. Sweeney, J. Vasic, David W Galbraith, Bane V Vasic

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Advances in DNA sequencing have resulted in instruments of remarkable performance, including extraordinary base read rates, and enormous sequencing depths. Sample throughput, nevertheless, remains slow, a situation that could be alleviated through sample multiplexing, with the incorporation of DNA barcodes serving to identify the different samples. Given the existence of finite sequencing error rates, reported is the design from BCH codes of DNA barcodes that provide guaranteed correction of errors within these barcodes.

Original languageEnglish (US)
Pages (from-to)236-237
Number of pages2
JournalElectronics Letters
Volume47
Issue number4
DOIs
StatePublished - Feb 17 2011

Fingerprint

Error correction
DNA
Multiplexing
Throughput

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Barcodes for DNA sequencing with guaranteed error correction capability. / Krishnan, A. R.; Sweeney, M.; Vasic, J.; Galbraith, David W; Vasic, Bane V.

In: Electronics Letters, Vol. 47, No. 4, 17.02.2011, p. 236-237.

Research output: Contribution to journalArticle

Krishnan, A. R. ; Sweeney, M. ; Vasic, J. ; Galbraith, David W ; Vasic, Bane V. / Barcodes for DNA sequencing with guaranteed error correction capability. In: Electronics Letters. 2011 ; Vol. 47, No. 4. pp. 236-237.
@article{3bab6a7807e84b3299797db4af612e77,
title = "Barcodes for DNA sequencing with guaranteed error correction capability",
abstract = "Advances in DNA sequencing have resulted in instruments of remarkable performance, including extraordinary base read rates, and enormous sequencing depths. Sample throughput, nevertheless, remains slow, a situation that could be alleviated through sample multiplexing, with the incorporation of DNA barcodes serving to identify the different samples. Given the existence of finite sequencing error rates, reported is the design from BCH codes of DNA barcodes that provide guaranteed correction of errors within these barcodes.",
author = "Krishnan, {A. R.} and M. Sweeney and J. Vasic and Galbraith, {David W} and Vasic, {Bane V}",
year = "2011",
month = "2",
day = "17",
doi = "10.1049/el.2010.3546",
language = "English (US)",
volume = "47",
pages = "236--237",
journal = "Electronics Letters",
issn = "0013-5194",
publisher = "Institution of Engineering and Technology",
number = "4",

}

TY - JOUR

T1 - Barcodes for DNA sequencing with guaranteed error correction capability

AU - Krishnan, A. R.

AU - Sweeney, M.

AU - Vasic, J.

AU - Galbraith, David W

AU - Vasic, Bane V

PY - 2011/2/17

Y1 - 2011/2/17

N2 - Advances in DNA sequencing have resulted in instruments of remarkable performance, including extraordinary base read rates, and enormous sequencing depths. Sample throughput, nevertheless, remains slow, a situation that could be alleviated through sample multiplexing, with the incorporation of DNA barcodes serving to identify the different samples. Given the existence of finite sequencing error rates, reported is the design from BCH codes of DNA barcodes that provide guaranteed correction of errors within these barcodes.

AB - Advances in DNA sequencing have resulted in instruments of remarkable performance, including extraordinary base read rates, and enormous sequencing depths. Sample throughput, nevertheless, remains slow, a situation that could be alleviated through sample multiplexing, with the incorporation of DNA barcodes serving to identify the different samples. Given the existence of finite sequencing error rates, reported is the design from BCH codes of DNA barcodes that provide guaranteed correction of errors within these barcodes.

UR - http://www.scopus.com/inward/record.url?scp=79951860587&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951860587&partnerID=8YFLogxK

U2 - 10.1049/el.2010.3546

DO - 10.1049/el.2010.3546

M3 - Article

AN - SCOPUS:79951860587

VL - 47

SP - 236

EP - 237

JO - Electronics Letters

JF - Electronics Letters

SN - 0013-5194

IS - 4

ER -