Burner and ultrasonic nebulizer improvements for atomic absorption spectrometry

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

An approach to optimized burner design for use with conventional commercial ultrasonic transducers is presented. Several burner designs are described that operate properly at very low flow rates so as to increase droplet residence time in the flame and minimize flow rate demands on the ultrasonic nebulizer. This system provides improved stability and an increase in sensitivity by atomic absorption of ten times compared with a conventional burner-pneumatic nebulizer system. The ultrasonic nebulization system is constructed for efficient introduction and changing of sample solutions.

Original languageEnglish (US)
Pages (from-to)241-247
Number of pages7
JournalAnalytical Chemistry
Volume44
Issue number2
StatePublished - 1972
Externally publishedYes

Fingerprint

Atomic absorption spectrometry
Fuel burners
Ultrasonics
Flow rate
Ultrasonic transducers
Pneumatics

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Burner and ultrasonic nebulizer improvements for atomic absorption spectrometry. / Denton, M Bonner.

In: Analytical Chemistry, Vol. 44, No. 2, 1972, p. 241-247.

Research output: Contribution to journalArticle

@article{7121daca25984ddbad0b26b7c39c7814,
title = "Burner and ultrasonic nebulizer improvements for atomic absorption spectrometry",
abstract = "An approach to optimized burner design for use with conventional commercial ultrasonic transducers is presented. Several burner designs are described that operate properly at very low flow rates so as to increase droplet residence time in the flame and minimize flow rate demands on the ultrasonic nebulizer. This system provides improved stability and an increase in sensitivity by atomic absorption of ten times compared with a conventional burner-pneumatic nebulizer system. The ultrasonic nebulization system is constructed for efficient introduction and changing of sample solutions.",
author = "Denton, {M Bonner}",
year = "1972",
language = "English (US)",
volume = "44",
pages = "241--247",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "2",

}

TY - JOUR

T1 - Burner and ultrasonic nebulizer improvements for atomic absorption spectrometry

AU - Denton, M Bonner

PY - 1972

Y1 - 1972

N2 - An approach to optimized burner design for use with conventional commercial ultrasonic transducers is presented. Several burner designs are described that operate properly at very low flow rates so as to increase droplet residence time in the flame and minimize flow rate demands on the ultrasonic nebulizer. This system provides improved stability and an increase in sensitivity by atomic absorption of ten times compared with a conventional burner-pneumatic nebulizer system. The ultrasonic nebulization system is constructed for efficient introduction and changing of sample solutions.

AB - An approach to optimized burner design for use with conventional commercial ultrasonic transducers is presented. Several burner designs are described that operate properly at very low flow rates so as to increase droplet residence time in the flame and minimize flow rate demands on the ultrasonic nebulizer. This system provides improved stability and an increase in sensitivity by atomic absorption of ten times compared with a conventional burner-pneumatic nebulizer system. The ultrasonic nebulization system is constructed for efficient introduction and changing of sample solutions.

UR - http://www.scopus.com/inward/record.url?scp=33947091789&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33947091789&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:33947091789

VL - 44

SP - 241

EP - 247