Abstract
A ceramic microdischarge arrays with individually ballasted pixels was discussed. It was found that spatially uniform glow excited states of the singly charged Xe ion, lying ∼ 26-27 eV above the neutral ground state were observed. The analysis showed that for a 169 element array drawing a total current of 30 mA, the output power of the array in the 300-1000 nm spectral region falls to ∼ 55% of its initial value in ∼ 8.3h of continuous operation with a static gas fill.
Original language | English (US) |
---|---|
Pages (from-to) | 2562-2564 |
Number of pages | 3 |
Journal | Applied Physics Letters |
Volume | 82 |
Issue number | 16 |
DOIs | |
State | Published - Apr 21 2003 |
Externally published | Yes |
Fingerprint
ASJC Scopus subject areas
- Physics and Astronomy (miscellaneous)
Cite this
Ceramic microdischarge arrays with individually ballasted pixels. / Von Allmen, P.; McCain, S. T.; Ostrom, N. P.; Vojak, B. A.; Eden, J. G.; Zenhausern, Frederic; Jensen, C.; Oliver, M.
In: Applied Physics Letters, Vol. 82, No. 16, 21.04.2003, p. 2562-2564.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Ceramic microdischarge arrays with individually ballasted pixels
AU - Von Allmen, P.
AU - McCain, S. T.
AU - Ostrom, N. P.
AU - Vojak, B. A.
AU - Eden, J. G.
AU - Zenhausern, Frederic
AU - Jensen, C.
AU - Oliver, M.
PY - 2003/4/21
Y1 - 2003/4/21
N2 - A ceramic microdischarge arrays with individually ballasted pixels was discussed. It was found that spatially uniform glow excited states of the singly charged Xe ion, lying ∼ 26-27 eV above the neutral ground state were observed. The analysis showed that for a 169 element array drawing a total current of 30 mA, the output power of the array in the 300-1000 nm spectral region falls to ∼ 55% of its initial value in ∼ 8.3h of continuous operation with a static gas fill.
AB - A ceramic microdischarge arrays with individually ballasted pixels was discussed. It was found that spatially uniform glow excited states of the singly charged Xe ion, lying ∼ 26-27 eV above the neutral ground state were observed. The analysis showed that for a 169 element array drawing a total current of 30 mA, the output power of the array in the 300-1000 nm spectral region falls to ∼ 55% of its initial value in ∼ 8.3h of continuous operation with a static gas fill.
UR - http://www.scopus.com/inward/record.url?scp=0037738491&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037738491&partnerID=8YFLogxK
U2 - 10.1063/1.1565186
DO - 10.1063/1.1565186
M3 - Article
AN - SCOPUS:0037738491
VL - 82
SP - 2562
EP - 2564
JO - Applied Physics Letters