CFD modeling to improve the design of a fog system for cooling greenhouses

Keesung Kim, Gene A Giacomelli, Jeong-Yeol Yoon, Sadanori Sase, Jung Eek Son, Sang Woon Nam, In Bok Lee

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A CFD model was developed to simulate the air temperature and relative humidity distribution in greenhouses adopting fog-cooling systems using FLUENT. The developed model was validated using the data from a fog-cooling experiment in a single-span greenhouse without plants. The measured and simulated air temperatures varied from 0.1 to 1.4°C and the differences of relative humidity varied 0.3-6.0%. The validated model was then used to evaluate the design of a fog-cooling system in a multi-span glasshouse. The optimal system design was determined in terms of the cooling efficiency and the special uniformity of air temperature and relative humidity. The simulations demonstrated that the best performance of the cooling system occurred when the fog nozzles were located at the height of 2.3 m above the floor and at a distance of 1.9 m from the sidewalls with uniform row-to-row spacing of 3.7 m. The most effective location of the nozzles was within the air entry from the sidewall ventilator inlets of the greenhouse. However, it was important not to wet the sidewalls with the fog. This study suggested that the CFD model developed could be a useful tool to design and evaluate the fog-cooling systems in greenhouses with various configurations.

Original languageEnglish (US)
Pages (from-to)283-290
Number of pages8
JournalJapan Agricultural Research Quarterly
Volume41
Issue number4
StatePublished - 2007

Fingerprint

Weather
fog
cooling systems
cooling
greenhouses
Humidity
air temperature
relative humidity
Air
modeling
nozzles
Temperature
ventilators
row spacing
Mechanical Ventilators
spacing
air
simulation
experiment

Keywords

  • CFD
  • Fog-cooling system
  • Glasshouse
  • Natural ventilation
  • Wind speed

ASJC Scopus subject areas

  • Agricultural and Biological Sciences (miscellaneous)

Cite this

CFD modeling to improve the design of a fog system for cooling greenhouses. / Kim, Keesung; Giacomelli, Gene A; Yoon, Jeong-Yeol; Sase, Sadanori; Son, Jung Eek; Nam, Sang Woon; Lee, In Bok.

In: Japan Agricultural Research Quarterly, Vol. 41, No. 4, 2007, p. 283-290.

Research output: Contribution to journalArticle

Kim, Keesung ; Giacomelli, Gene A ; Yoon, Jeong-Yeol ; Sase, Sadanori ; Son, Jung Eek ; Nam, Sang Woon ; Lee, In Bok. / CFD modeling to improve the design of a fog system for cooling greenhouses. In: Japan Agricultural Research Quarterly. 2007 ; Vol. 41, No. 4. pp. 283-290.
@article{ca9c844ace8a41b781aef70a62715f95,
title = "CFD modeling to improve the design of a fog system for cooling greenhouses",
abstract = "A CFD model was developed to simulate the air temperature and relative humidity distribution in greenhouses adopting fog-cooling systems using FLUENT. The developed model was validated using the data from a fog-cooling experiment in a single-span greenhouse without plants. The measured and simulated air temperatures varied from 0.1 to 1.4°C and the differences of relative humidity varied 0.3-6.0{\%}. The validated model was then used to evaluate the design of a fog-cooling system in a multi-span glasshouse. The optimal system design was determined in terms of the cooling efficiency and the special uniformity of air temperature and relative humidity. The simulations demonstrated that the best performance of the cooling system occurred when the fog nozzles were located at the height of 2.3 m above the floor and at a distance of 1.9 m from the sidewalls with uniform row-to-row spacing of 3.7 m. The most effective location of the nozzles was within the air entry from the sidewall ventilator inlets of the greenhouse. However, it was important not to wet the sidewalls with the fog. This study suggested that the CFD model developed could be a useful tool to design and evaluate the fog-cooling systems in greenhouses with various configurations.",
keywords = "CFD, Fog-cooling system, Glasshouse, Natural ventilation, Wind speed",
author = "Keesung Kim and Giacomelli, {Gene A} and Jeong-Yeol Yoon and Sadanori Sase and Son, {Jung Eek} and Nam, {Sang Woon} and Lee, {In Bok}",
year = "2007",
language = "English (US)",
volume = "41",
pages = "283--290",
journal = "Japan Agricultural Research Quarterly",
issn = "0021-3551",
publisher = "Japan International Research Center for Agricultural Sciences",
number = "4",

}

TY - JOUR

T1 - CFD modeling to improve the design of a fog system for cooling greenhouses

AU - Kim, Keesung

AU - Giacomelli, Gene A

AU - Yoon, Jeong-Yeol

AU - Sase, Sadanori

AU - Son, Jung Eek

AU - Nam, Sang Woon

AU - Lee, In Bok

PY - 2007

Y1 - 2007

N2 - A CFD model was developed to simulate the air temperature and relative humidity distribution in greenhouses adopting fog-cooling systems using FLUENT. The developed model was validated using the data from a fog-cooling experiment in a single-span greenhouse without plants. The measured and simulated air temperatures varied from 0.1 to 1.4°C and the differences of relative humidity varied 0.3-6.0%. The validated model was then used to evaluate the design of a fog-cooling system in a multi-span glasshouse. The optimal system design was determined in terms of the cooling efficiency and the special uniformity of air temperature and relative humidity. The simulations demonstrated that the best performance of the cooling system occurred when the fog nozzles were located at the height of 2.3 m above the floor and at a distance of 1.9 m from the sidewalls with uniform row-to-row spacing of 3.7 m. The most effective location of the nozzles was within the air entry from the sidewall ventilator inlets of the greenhouse. However, it was important not to wet the sidewalls with the fog. This study suggested that the CFD model developed could be a useful tool to design and evaluate the fog-cooling systems in greenhouses with various configurations.

AB - A CFD model was developed to simulate the air temperature and relative humidity distribution in greenhouses adopting fog-cooling systems using FLUENT. The developed model was validated using the data from a fog-cooling experiment in a single-span greenhouse without plants. The measured and simulated air temperatures varied from 0.1 to 1.4°C and the differences of relative humidity varied 0.3-6.0%. The validated model was then used to evaluate the design of a fog-cooling system in a multi-span glasshouse. The optimal system design was determined in terms of the cooling efficiency and the special uniformity of air temperature and relative humidity. The simulations demonstrated that the best performance of the cooling system occurred when the fog nozzles were located at the height of 2.3 m above the floor and at a distance of 1.9 m from the sidewalls with uniform row-to-row spacing of 3.7 m. The most effective location of the nozzles was within the air entry from the sidewall ventilator inlets of the greenhouse. However, it was important not to wet the sidewalls with the fog. This study suggested that the CFD model developed could be a useful tool to design and evaluate the fog-cooling systems in greenhouses with various configurations.

KW - CFD

KW - Fog-cooling system

KW - Glasshouse

KW - Natural ventilation

KW - Wind speed

UR - http://www.scopus.com/inward/record.url?scp=36749025692&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=36749025692&partnerID=8YFLogxK

M3 - Article

VL - 41

SP - 283

EP - 290

JO - Japan Agricultural Research Quarterly

JF - Japan Agricultural Research Quarterly

SN - 0021-3551

IS - 4

ER -