Comparable change in stromal refractive index of cat and human corneas following blue-IRIS

Kaitlin T. Wozniak, Sara M. Gearhart, Daniel E. Savage, Jonathan D. Ellis, Wayne H. Knox, Krystel R. Huxlin

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Blue intratissue refractive index shaping (blue-IRIS) is a method with potential to correct ocular refraction noninvasively in humans. To date, blue-IRIS has only ever been applied to cat corneas and hydrogels. To test the comparability of refractive index change achievable in cat and human tissues, we used blue-IRIS to write identical phase gratings in ex vivo feline and human corneas. Femtosecond pulses (400 nm) were focused ∼300 μm below the epithelial surface of excised cat and human corneas and scanned to write phase gratings with lines ∼1 μm wide, spaced 5 μm apart, using a scan speed of 5 mm/s. Additional cat corneas were used to test writing at 3 and 7 mm/s in order to document speed dependence of the refractive index change magnitude. The first-order diffraction efficiency was immediately measured and used to calculate the refractive index change attained. Our data show that blue-IRIS induces comparable refractive index changes in feline and human corneas, an essential requirement for further developing its use as a clinical vision correction technique.

Original languageEnglish (US)
Article number055007
JournalJournal of biomedical optics
Volume22
Issue number5
DOIs
StatePublished - Jan 1 2017
Externally publishedYes

Fingerprint

cornea
cats
Refractive index
refractivity
Vision aids
gratings
Hydrogels
Diffraction efficiency
Ultrashort pulses
Refraction
refraction
Tissue
requirements
pulses
diffraction

Keywords

  • cornea
  • femtosecond
  • refractive
  • stroma

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Atomic and Molecular Physics, and Optics
  • Biomedical Engineering

Cite this

Comparable change in stromal refractive index of cat and human corneas following blue-IRIS. / Wozniak, Kaitlin T.; Gearhart, Sara M.; Savage, Daniel E.; Ellis, Jonathan D.; Knox, Wayne H.; Huxlin, Krystel R.

In: Journal of biomedical optics, Vol. 22, No. 5, 055007, 01.01.2017.

Research output: Contribution to journalArticle

Wozniak, Kaitlin T. ; Gearhart, Sara M. ; Savage, Daniel E. ; Ellis, Jonathan D. ; Knox, Wayne H. ; Huxlin, Krystel R. / Comparable change in stromal refractive index of cat and human corneas following blue-IRIS. In: Journal of biomedical optics. 2017 ; Vol. 22, No. 5.
@article{9d77f0cc95e8408a8e3714d69127a0ec,
title = "Comparable change in stromal refractive index of cat and human corneas following blue-IRIS",
abstract = "Blue intratissue refractive index shaping (blue-IRIS) is a method with potential to correct ocular refraction noninvasively in humans. To date, blue-IRIS has only ever been applied to cat corneas and hydrogels. To test the comparability of refractive index change achievable in cat and human tissues, we used blue-IRIS to write identical phase gratings in ex vivo feline and human corneas. Femtosecond pulses (400 nm) were focused ∼300 μm below the epithelial surface of excised cat and human corneas and scanned to write phase gratings with lines ∼1 μm wide, spaced 5 μm apart, using a scan speed of 5 mm/s. Additional cat corneas were used to test writing at 3 and 7 mm/s in order to document speed dependence of the refractive index change magnitude. The first-order diffraction efficiency was immediately measured and used to calculate the refractive index change attained. Our data show that blue-IRIS induces comparable refractive index changes in feline and human corneas, an essential requirement for further developing its use as a clinical vision correction technique.",
keywords = "cornea, femtosecond, refractive, stroma",
author = "Wozniak, {Kaitlin T.} and Gearhart, {Sara M.} and Savage, {Daniel E.} and Ellis, {Jonathan D.} and Knox, {Wayne H.} and Huxlin, {Krystel R.}",
year = "2017",
month = "1",
day = "1",
doi = "10.1117/1.JBO.22.5.055007",
language = "English (US)",
volume = "22",
journal = "Journal of Biomedical Optics",
issn = "1083-3668",
publisher = "SPIE",
number = "5",

}

TY - JOUR

T1 - Comparable change in stromal refractive index of cat and human corneas following blue-IRIS

AU - Wozniak, Kaitlin T.

AU - Gearhart, Sara M.

AU - Savage, Daniel E.

AU - Ellis, Jonathan D.

AU - Knox, Wayne H.

AU - Huxlin, Krystel R.

PY - 2017/1/1

Y1 - 2017/1/1

N2 - Blue intratissue refractive index shaping (blue-IRIS) is a method with potential to correct ocular refraction noninvasively in humans. To date, blue-IRIS has only ever been applied to cat corneas and hydrogels. To test the comparability of refractive index change achievable in cat and human tissues, we used blue-IRIS to write identical phase gratings in ex vivo feline and human corneas. Femtosecond pulses (400 nm) were focused ∼300 μm below the epithelial surface of excised cat and human corneas and scanned to write phase gratings with lines ∼1 μm wide, spaced 5 μm apart, using a scan speed of 5 mm/s. Additional cat corneas were used to test writing at 3 and 7 mm/s in order to document speed dependence of the refractive index change magnitude. The first-order diffraction efficiency was immediately measured and used to calculate the refractive index change attained. Our data show that blue-IRIS induces comparable refractive index changes in feline and human corneas, an essential requirement for further developing its use as a clinical vision correction technique.

AB - Blue intratissue refractive index shaping (blue-IRIS) is a method with potential to correct ocular refraction noninvasively in humans. To date, blue-IRIS has only ever been applied to cat corneas and hydrogels. To test the comparability of refractive index change achievable in cat and human tissues, we used blue-IRIS to write identical phase gratings in ex vivo feline and human corneas. Femtosecond pulses (400 nm) were focused ∼300 μm below the epithelial surface of excised cat and human corneas and scanned to write phase gratings with lines ∼1 μm wide, spaced 5 μm apart, using a scan speed of 5 mm/s. Additional cat corneas were used to test writing at 3 and 7 mm/s in order to document speed dependence of the refractive index change magnitude. The first-order diffraction efficiency was immediately measured and used to calculate the refractive index change attained. Our data show that blue-IRIS induces comparable refractive index changes in feline and human corneas, an essential requirement for further developing its use as a clinical vision correction technique.

KW - cornea

KW - femtosecond

KW - refractive

KW - stroma

UR - http://www.scopus.com/inward/record.url?scp=85019986417&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85019986417&partnerID=8YFLogxK

U2 - 10.1117/1.JBO.22.5.055007

DO - 10.1117/1.JBO.22.5.055007

M3 - Article

C2 - 28538957

AN - SCOPUS:85019986417

VL - 22

JO - Journal of Biomedical Optics

JF - Journal of Biomedical Optics

SN - 1083-3668

IS - 5

M1 - 055007

ER -