Comparison of a very high frequency 148 MHz inductively coupled plasma to a 27 MHz ICP

Bryan D. Webb, M Bonner Denton

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

Physical parameters and analytical performance are determined for an analytical ICP operated at 148 MHz, a frequency nearly three times higher than any previously reported. The iron(I) excitation temperatures are approximately 1.5 times lower and the electron densities are five times lower than at 27 MHz. The consequences of these changes are lower analyte and background continuum emission intensities, such that the signal to background ratios are decreased at the higher frequency. Freedom from interferences and working curve linearity are unaffected while ease of sample introduction is improved. A shift towards atomic emission indicates a deviation farther from LTE at 148 MHz. These effects are attributed to the decrease in skin depth with increasing frequency.

Original languageEnglish (US)
Pages (from-to)361-376
Number of pages16
JournalSpectrochimica Acta Part B: Atomic Spectroscopy
Volume41
Issue number4
DOIs
StatePublished - 1986

Fingerprint

very high frequencies
Inductively coupled plasma
Carrier concentration
Skin
Iron
local thermodynamic equilibrium
linearity
continuums
deviation
interference
iron
Temperature
shift
curves
excitation
temperature

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Comparison of a very high frequency 148 MHz inductively coupled plasma to a 27 MHz ICP. / Webb, Bryan D.; Denton, M Bonner.

In: Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 41, No. 4, 1986, p. 361-376.

Research output: Contribution to journalArticle

@article{c71710d88a254c88abc6056421e21e77,
title = "Comparison of a very high frequency 148 MHz inductively coupled plasma to a 27 MHz ICP",
abstract = "Physical parameters and analytical performance are determined for an analytical ICP operated at 148 MHz, a frequency nearly three times higher than any previously reported. The iron(I) excitation temperatures are approximately 1.5 times lower and the electron densities are five times lower than at 27 MHz. The consequences of these changes are lower analyte and background continuum emission intensities, such that the signal to background ratios are decreased at the higher frequency. Freedom from interferences and working curve linearity are unaffected while ease of sample introduction is improved. A shift towards atomic emission indicates a deviation farther from LTE at 148 MHz. These effects are attributed to the decrease in skin depth with increasing frequency.",
author = "Webb, {Bryan D.} and Denton, {M Bonner}",
year = "1986",
doi = "10.1016/0584-8547(86)80062-3",
language = "English (US)",
volume = "41",
pages = "361--376",
journal = "Spectrochimica Acta, Part B: Atomic Spectroscopy",
issn = "0584-8547",
publisher = "Elsevier",
number = "4",

}

TY - JOUR

T1 - Comparison of a very high frequency 148 MHz inductively coupled plasma to a 27 MHz ICP

AU - Webb, Bryan D.

AU - Denton, M Bonner

PY - 1986

Y1 - 1986

N2 - Physical parameters and analytical performance are determined for an analytical ICP operated at 148 MHz, a frequency nearly three times higher than any previously reported. The iron(I) excitation temperatures are approximately 1.5 times lower and the electron densities are five times lower than at 27 MHz. The consequences of these changes are lower analyte and background continuum emission intensities, such that the signal to background ratios are decreased at the higher frequency. Freedom from interferences and working curve linearity are unaffected while ease of sample introduction is improved. A shift towards atomic emission indicates a deviation farther from LTE at 148 MHz. These effects are attributed to the decrease in skin depth with increasing frequency.

AB - Physical parameters and analytical performance are determined for an analytical ICP operated at 148 MHz, a frequency nearly three times higher than any previously reported. The iron(I) excitation temperatures are approximately 1.5 times lower and the electron densities are five times lower than at 27 MHz. The consequences of these changes are lower analyte and background continuum emission intensities, such that the signal to background ratios are decreased at the higher frequency. Freedom from interferences and working curve linearity are unaffected while ease of sample introduction is improved. A shift towards atomic emission indicates a deviation farther from LTE at 148 MHz. These effects are attributed to the decrease in skin depth with increasing frequency.

UR - http://www.scopus.com/inward/record.url?scp=0041777581&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0041777581&partnerID=8YFLogxK

U2 - 10.1016/0584-8547(86)80062-3

DO - 10.1016/0584-8547(86)80062-3

M3 - Article

VL - 41

SP - 361

EP - 376

JO - Spectrochimica Acta, Part B: Atomic Spectroscopy

JF - Spectrochimica Acta, Part B: Atomic Spectroscopy

SN - 0584-8547

IS - 4

ER -