Compatibility of a diffractive pupil and coronagraphic imaging

Eduardo Bendek, Ruslan Belikov, Eugene Pluzhnik, Olivier Guyon

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Detection and characterization of exo-Earths require direct imaging techniques that can deliver contrast ratios of 1010 at 100 mas or smaller angular separation. At the same time, astrometric data is required to measure planet masses and to help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high-efficiency coronagraph to perform direct imaging and a diffractive pupil to calibrate wide field distortions to enable high-precision astrometric measurements. This article reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronagraphic imaging systems. No diffractive contamination was found within our detectability limit of 2 × 10-7 contrast outside a region of 12 λ=D and 2:5 × 10-6 within a region spanning from 2 to 12 λ=D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10-7 or better contrast.

Original languageEnglish (US)
Pages (from-to)204-212
Number of pages9
JournalPublications of the Astronomical Society of the Pacific
Volume125
Issue number924
DOIs
StatePublished - Feb 2013

Fingerprint

pupils
compatibility
contamination
planet
planets
active control
coronagraphs
test stands
space missions
imaging techniques
costs
cost
orbitals

Keywords

  • Color figures

ASJC Scopus subject areas

  • Astronomy and Astrophysics
  • Space and Planetary Science

Cite this

Compatibility of a diffractive pupil and coronagraphic imaging. / Bendek, Eduardo; Belikov, Ruslan; Pluzhnik, Eugene; Guyon, Olivier.

In: Publications of the Astronomical Society of the Pacific, Vol. 125, No. 924, 02.2013, p. 204-212.

Research output: Contribution to journalArticle

Bendek, Eduardo ; Belikov, Ruslan ; Pluzhnik, Eugene ; Guyon, Olivier. / Compatibility of a diffractive pupil and coronagraphic imaging. In: Publications of the Astronomical Society of the Pacific. 2013 ; Vol. 125, No. 924. pp. 204-212.
@article{5e4e237185084512a6adbf296b821f0b,
title = "Compatibility of a diffractive pupil and coronagraphic imaging",
abstract = "Detection and characterization of exo-Earths require direct imaging techniques that can deliver contrast ratios of 1010 at 100 mas or smaller angular separation. At the same time, astrometric data is required to measure planet masses and to help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high-efficiency coronagraph to perform direct imaging and a diffractive pupil to calibrate wide field distortions to enable high-precision astrometric measurements. This article reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronagraphic imaging systems. No diffractive contamination was found within our detectability limit of 2 × 10-7 contrast outside a region of 12 λ=D and 2:5 × 10-6 within a region spanning from 2 to 12 λ=D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10-7 or better contrast.",
keywords = "Color figures",
author = "Eduardo Bendek and Ruslan Belikov and Eugene Pluzhnik and Olivier Guyon",
year = "2013",
month = "2",
doi = "10.1086/669824",
language = "English (US)",
volume = "125",
pages = "204--212",
journal = "Publications of the Astronomical Society of the Pacific",
issn = "0004-6280",
publisher = "University of Chicago",
number = "924",

}

TY - JOUR

T1 - Compatibility of a diffractive pupil and coronagraphic imaging

AU - Bendek, Eduardo

AU - Belikov, Ruslan

AU - Pluzhnik, Eugene

AU - Guyon, Olivier

PY - 2013/2

Y1 - 2013/2

N2 - Detection and characterization of exo-Earths require direct imaging techniques that can deliver contrast ratios of 1010 at 100 mas or smaller angular separation. At the same time, astrometric data is required to measure planet masses and to help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high-efficiency coronagraph to perform direct imaging and a diffractive pupil to calibrate wide field distortions to enable high-precision astrometric measurements. This article reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronagraphic imaging systems. No diffractive contamination was found within our detectability limit of 2 × 10-7 contrast outside a region of 12 λ=D and 2:5 × 10-6 within a region spanning from 2 to 12 λ=D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10-7 or better contrast.

AB - Detection and characterization of exo-Earths require direct imaging techniques that can deliver contrast ratios of 1010 at 100 mas or smaller angular separation. At the same time, astrometric data is required to measure planet masses and to help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high-efficiency coronagraph to perform direct imaging and a diffractive pupil to calibrate wide field distortions to enable high-precision astrometric measurements. This article reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronagraphic imaging systems. No diffractive contamination was found within our detectability limit of 2 × 10-7 contrast outside a region of 12 λ=D and 2:5 × 10-6 within a region spanning from 2 to 12 λ=D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10-7 or better contrast.

KW - Color figures

UR - http://www.scopus.com/inward/record.url?scp=84874244698&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874244698&partnerID=8YFLogxK

U2 - 10.1086/669824

DO - 10.1086/669824

M3 - Article

VL - 125

SP - 204

EP - 212

JO - Publications of the Astronomical Society of the Pacific

JF - Publications of the Astronomical Society of the Pacific

SN - 0004-6280

IS - 924

ER -