Complications associated with needle localization biopsy of the breast

William - Adamas-Rappaport, S. Thompson, R. Wong, S. Leong, H. Villar

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

A review of 144 consecutive needle localization biopsies of the breast (NLBB) was performed to assess complications associated with this procedure. Thirty-four complications occurred in 27 patients. There were 11 wound infections associated with NLBB. During this time period, there were 1,583 clean general surgical operations performed, other than biopsy of the breast, yielding an over-all wound infection rate of 1.2 per cent (p<0.001). A trend was noted, suggesting that use of drains may have contributed to wound infection versus no drainage (25 versus 5 per cent, respectively). Electrocautery burns requiring local wound care occurred during seven biopsies and four of these patients subsequently had a wound infection develop. Four lesions required more than one excision to remove the abnormal mammary tissue, and in four, there was a failure to remove the lesion at the first operation. Fifty-three localization procedures were performed using methylene blue. In this group, only one patient required more than one biopsy to remove the abnormal mammary tissue, and there were no failures with this technique. Also, a smaller mean volume of tissue was removed in this group versus the standard NLBB (30.2±3.0 versus 53.3±4.6 cubic millimeters, respectively) (p<0.01). Four cardiovascular complications occurred, requiring overnight admission. All of these patients were more than 65 years old and had the procedure performed while under general anesthesia. Patient age, type of anesthesia, resident versus attending surgeon and length of procedure had no independent effect on local complication rate.

Original languageEnglish (US)
Pages (from-to)303-306
Number of pages4
JournalSurgery Gynecology and Obstetrics
Volume172
Issue number4
StatePublished - 1991
Externally publishedYes

Fingerprint

Needle Biopsy
Breast
Wound Infection
Biopsy
Electrocoagulation
Methylene Blue
Burns
General Anesthesia
Drainage
Anesthesia
Wounds and Injuries

ASJC Scopus subject areas

  • Obstetrics and Gynecology
  • Surgery

Cite this

Complications associated with needle localization biopsy of the breast. / Adamas-Rappaport, William -; Thompson, S.; Wong, R.; Leong, S.; Villar, H.

In: Surgery Gynecology and Obstetrics, Vol. 172, No. 4, 1991, p. 303-306.

Research output: Contribution to journalArticle

Adamas-Rappaport, W, Thompson, S, Wong, R, Leong, S & Villar, H 1991, 'Complications associated with needle localization biopsy of the breast', Surgery Gynecology and Obstetrics, vol. 172, no. 4, pp. 303-306.
Adamas-Rappaport, William - ; Thompson, S. ; Wong, R. ; Leong, S. ; Villar, H. / Complications associated with needle localization biopsy of the breast. In: Surgery Gynecology and Obstetrics. 1991 ; Vol. 172, No. 4. pp. 303-306.
@article{fa62b8dbaa4a49ecb5932b0cc4ba31ef,
title = "Complications associated with needle localization biopsy of the breast",
abstract = "A review of 144 consecutive needle localization biopsies of the breast (NLBB) was performed to assess complications associated with this procedure. Thirty-four complications occurred in 27 patients. There were 11 wound infections associated with NLBB. During this time period, there were 1,583 clean general surgical operations performed, other than biopsy of the breast, yielding an over-all wound infection rate of 1.2 per cent (p<0.001). A trend was noted, suggesting that use of drains may have contributed to wound infection versus no drainage (25 versus 5 per cent, respectively). Electrocautery burns requiring local wound care occurred during seven biopsies and four of these patients subsequently had a wound infection develop. Four lesions required more than one excision to remove the abnormal mammary tissue, and in four, there was a failure to remove the lesion at the first operation. Fifty-three localization procedures were performed using methylene blue. In this group, only one patient required more than one biopsy to remove the abnormal mammary tissue, and there were no failures with this technique. Also, a smaller mean volume of tissue was removed in this group versus the standard NLBB (30.2±3.0 versus 53.3±4.6 cubic millimeters, respectively) (p<0.01). Four cardiovascular complications occurred, requiring overnight admission. All of these patients were more than 65 years old and had the procedure performed while under general anesthesia. Patient age, type of anesthesia, resident versus attending surgeon and length of procedure had no independent effect on local complication rate.",
author = "Adamas-Rappaport, {William -} and S. Thompson and R. Wong and S. Leong and H. Villar",
year = "1991",
language = "English (US)",
volume = "172",
pages = "303--306",
journal = "Journal of the American College of Surgeons",
issn = "1072-7515",
publisher = "Elsevier Inc.",
number = "4",

}

TY - JOUR

T1 - Complications associated with needle localization biopsy of the breast

AU - Adamas-Rappaport, William -

AU - Thompson, S.

AU - Wong, R.

AU - Leong, S.

AU - Villar, H.

PY - 1991

Y1 - 1991

N2 - A review of 144 consecutive needle localization biopsies of the breast (NLBB) was performed to assess complications associated with this procedure. Thirty-four complications occurred in 27 patients. There were 11 wound infections associated with NLBB. During this time period, there were 1,583 clean general surgical operations performed, other than biopsy of the breast, yielding an over-all wound infection rate of 1.2 per cent (p<0.001). A trend was noted, suggesting that use of drains may have contributed to wound infection versus no drainage (25 versus 5 per cent, respectively). Electrocautery burns requiring local wound care occurred during seven biopsies and four of these patients subsequently had a wound infection develop. Four lesions required more than one excision to remove the abnormal mammary tissue, and in four, there was a failure to remove the lesion at the first operation. Fifty-three localization procedures were performed using methylene blue. In this group, only one patient required more than one biopsy to remove the abnormal mammary tissue, and there were no failures with this technique. Also, a smaller mean volume of tissue was removed in this group versus the standard NLBB (30.2±3.0 versus 53.3±4.6 cubic millimeters, respectively) (p<0.01). Four cardiovascular complications occurred, requiring overnight admission. All of these patients were more than 65 years old and had the procedure performed while under general anesthesia. Patient age, type of anesthesia, resident versus attending surgeon and length of procedure had no independent effect on local complication rate.

AB - A review of 144 consecutive needle localization biopsies of the breast (NLBB) was performed to assess complications associated with this procedure. Thirty-four complications occurred in 27 patients. There were 11 wound infections associated with NLBB. During this time period, there were 1,583 clean general surgical operations performed, other than biopsy of the breast, yielding an over-all wound infection rate of 1.2 per cent (p<0.001). A trend was noted, suggesting that use of drains may have contributed to wound infection versus no drainage (25 versus 5 per cent, respectively). Electrocautery burns requiring local wound care occurred during seven biopsies and four of these patients subsequently had a wound infection develop. Four lesions required more than one excision to remove the abnormal mammary tissue, and in four, there was a failure to remove the lesion at the first operation. Fifty-three localization procedures were performed using methylene blue. In this group, only one patient required more than one biopsy to remove the abnormal mammary tissue, and there were no failures with this technique. Also, a smaller mean volume of tissue was removed in this group versus the standard NLBB (30.2±3.0 versus 53.3±4.6 cubic millimeters, respectively) (p<0.01). Four cardiovascular complications occurred, requiring overnight admission. All of these patients were more than 65 years old and had the procedure performed while under general anesthesia. Patient age, type of anesthesia, resident versus attending surgeon and length of procedure had no independent effect on local complication rate.

UR - http://www.scopus.com/inward/record.url?scp=0025891216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025891216&partnerID=8YFLogxK

M3 - Article

VL - 172

SP - 303

EP - 306

JO - Journal of the American College of Surgeons

JF - Journal of the American College of Surgeons

SN - 1072-7515

IS - 4

ER -