Abstract

A ground-water treatment process is described in which contaminants are adsorbed onto granulated activated carbon (GAC) containing fixed iron oxide. Hydrogen peroxide (H2O2) is amended to the GAC suspension and reacts with the iron, forming hydroxyl radicals (.OH). The radicals react with and oxidize sorbed and soluble contaminants regenerating the carbon surface. Laboratory results are presented in which 2-chlorophenol (2CP) was first adsorbed to GAC and subsequently oxidized via the Fenton-driven mechanism. Transformation of 2CP was indicated by the formation of carboxylic acids and Cl-release. The treatment efficiency of 2CP, defined as the molar ratio of Cl-released to H2O2 consumed, increased with increasing amounts of iron oxide and 2CP on the GAC. The extent of 2CP oxidation increased with H2O2 concentration. Lower treatment efficiency was evident at the highest H2O2 concentration utilized (2.1 M) and was attributed to increased .OH scavenging by H2O2. Aggressive oxidation procedures used in sequential adsorption/oxidation cycles did not alter the GAC surface to a degree that significantly interfered with subsequent 2CP adsorption reactions. Although process feasibility has not yet been established beyond bench-scale, experimental results illustrate the potential utility of the adsorption/oxidation process in aboveground systems or permeable reactive barriers for the treatment of contaminated ground water.

Original languageEnglish (US)
Pages (from-to)595-600
Number of pages6
JournalJournal of Environmental Engineering
Volume126
Issue number7
DOIs
StatePublished - 2000

Fingerprint

chlorophenol
Activated carbon
activated carbon
Impurities
adsorption
Adsorption
oxidation
Oxidation
pollutant
Iron oxides
Groundwater
iron oxide
Scavenging
reactive barrier
Water treatment
Carboxylic acids
groundwater
Hydrogen peroxide
carboxylic acid
hydroxyl radical

ASJC Scopus subject areas

  • Environmental Engineering
  • Environmental Science(all)
  • Environmental Chemistry
  • Civil and Structural Engineering

Cite this

Contaminant adsorption and oxidation via Fenton reaction. / Huling, Scott G.; Arnold, Robert G; Sierka, Raymond A.; Jones, Patrick K.; Fine, Dennis D.

In: Journal of Environmental Engineering, Vol. 126, No. 7, 2000, p. 595-600.

Research output: Contribution to journalArticle

Huling, Scott G. ; Arnold, Robert G ; Sierka, Raymond A. ; Jones, Patrick K. ; Fine, Dennis D. / Contaminant adsorption and oxidation via Fenton reaction. In: Journal of Environmental Engineering. 2000 ; Vol. 126, No. 7. pp. 595-600.
@article{bb434593cbc6454a84b3eb7dffa56715,
title = "Contaminant adsorption and oxidation via Fenton reaction",
abstract = "A ground-water treatment process is described in which contaminants are adsorbed onto granulated activated carbon (GAC) containing fixed iron oxide. Hydrogen peroxide (H2O2) is amended to the GAC suspension and reacts with the iron, forming hydroxyl radicals (.OH). The radicals react with and oxidize sorbed and soluble contaminants regenerating the carbon surface. Laboratory results are presented in which 2-chlorophenol (2CP) was first adsorbed to GAC and subsequently oxidized via the Fenton-driven mechanism. Transformation of 2CP was indicated by the formation of carboxylic acids and Cl-release. The treatment efficiency of 2CP, defined as the molar ratio of Cl-released to H2O2 consumed, increased with increasing amounts of iron oxide and 2CP on the GAC. The extent of 2CP oxidation increased with H2O2 concentration. Lower treatment efficiency was evident at the highest H2O2 concentration utilized (2.1 M) and was attributed to increased .OH scavenging by H2O2. Aggressive oxidation procedures used in sequential adsorption/oxidation cycles did not alter the GAC surface to a degree that significantly interfered with subsequent 2CP adsorption reactions. Although process feasibility has not yet been established beyond bench-scale, experimental results illustrate the potential utility of the adsorption/oxidation process in aboveground systems or permeable reactive barriers for the treatment of contaminated ground water.",
author = "Huling, {Scott G.} and Arnold, {Robert G} and Sierka, {Raymond A.} and Jones, {Patrick K.} and Fine, {Dennis D.}",
year = "2000",
doi = "10.1061/(ASCE)0733-9372(2000)126:7(595)",
language = "English (US)",
volume = "126",
pages = "595--600",
journal = "Journal of Environmental Engineering, ASCE",
issn = "0733-9372",
publisher = "American Society of Civil Engineers (ASCE)",
number = "7",

}

TY - JOUR

T1 - Contaminant adsorption and oxidation via Fenton reaction

AU - Huling, Scott G.

AU - Arnold, Robert G

AU - Sierka, Raymond A.

AU - Jones, Patrick K.

AU - Fine, Dennis D.

PY - 2000

Y1 - 2000

N2 - A ground-water treatment process is described in which contaminants are adsorbed onto granulated activated carbon (GAC) containing fixed iron oxide. Hydrogen peroxide (H2O2) is amended to the GAC suspension and reacts with the iron, forming hydroxyl radicals (.OH). The radicals react with and oxidize sorbed and soluble contaminants regenerating the carbon surface. Laboratory results are presented in which 2-chlorophenol (2CP) was first adsorbed to GAC and subsequently oxidized via the Fenton-driven mechanism. Transformation of 2CP was indicated by the formation of carboxylic acids and Cl-release. The treatment efficiency of 2CP, defined as the molar ratio of Cl-released to H2O2 consumed, increased with increasing amounts of iron oxide and 2CP on the GAC. The extent of 2CP oxidation increased with H2O2 concentration. Lower treatment efficiency was evident at the highest H2O2 concentration utilized (2.1 M) and was attributed to increased .OH scavenging by H2O2. Aggressive oxidation procedures used in sequential adsorption/oxidation cycles did not alter the GAC surface to a degree that significantly interfered with subsequent 2CP adsorption reactions. Although process feasibility has not yet been established beyond bench-scale, experimental results illustrate the potential utility of the adsorption/oxidation process in aboveground systems or permeable reactive barriers for the treatment of contaminated ground water.

AB - A ground-water treatment process is described in which contaminants are adsorbed onto granulated activated carbon (GAC) containing fixed iron oxide. Hydrogen peroxide (H2O2) is amended to the GAC suspension and reacts with the iron, forming hydroxyl radicals (.OH). The radicals react with and oxidize sorbed and soluble contaminants regenerating the carbon surface. Laboratory results are presented in which 2-chlorophenol (2CP) was first adsorbed to GAC and subsequently oxidized via the Fenton-driven mechanism. Transformation of 2CP was indicated by the formation of carboxylic acids and Cl-release. The treatment efficiency of 2CP, defined as the molar ratio of Cl-released to H2O2 consumed, increased with increasing amounts of iron oxide and 2CP on the GAC. The extent of 2CP oxidation increased with H2O2 concentration. Lower treatment efficiency was evident at the highest H2O2 concentration utilized (2.1 M) and was attributed to increased .OH scavenging by H2O2. Aggressive oxidation procedures used in sequential adsorption/oxidation cycles did not alter the GAC surface to a degree that significantly interfered with subsequent 2CP adsorption reactions. Although process feasibility has not yet been established beyond bench-scale, experimental results illustrate the potential utility of the adsorption/oxidation process in aboveground systems or permeable reactive barriers for the treatment of contaminated ground water.

UR - http://www.scopus.com/inward/record.url?scp=0033924999&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033924999&partnerID=8YFLogxK

U2 - 10.1061/(ASCE)0733-9372(2000)126:7(595)

DO - 10.1061/(ASCE)0733-9372(2000)126:7(595)

M3 - Article

VL - 126

SP - 595

EP - 600

JO - Journal of Environmental Engineering, ASCE

JF - Journal of Environmental Engineering, ASCE

SN - 0733-9372

IS - 7

ER -