Delayed hypersensitivity responses of cancer patients to recall antigens using a new 'Multitest' applicator

J. M. Reuben, Evan M Hersh

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Testing of delayed-type hypersensitivity to recall antigens is acknowledged to be a useful assessment of cell-mediated immunity in cancer patients. The conventional method, however, has suffered from a lack of standardized antigens and variability owing to the method of application of the recall antigens. The Multitest-CMI system by the Merieux Institute offers an alternative. It employs standardized antigens and a single-stroke applicator, which is simpler to use and presumably subject to less variation. The present study compares the conventional and Multitest batteries done over an 8-month period in 403 cancer patients. The results suggest that the Multitest is easier to administer and is tolerated better by patients than the conventional method. Furthermore, the Multitest can detect recall antigen anergy or reactivity and correlates well in degrees of reactivity to the individual test battery. Consequently, Multitest-CMI can be substituted for the conventional battery in skin testing for immunocompetence in cancer patients.

Original languageEnglish (US)
Pages (from-to)390-394
Number of pages5
JournalAnnals of Allergy
Volume53
Issue number5
StatePublished - 1984
Externally publishedYes

Fingerprint

Delayed Hypersensitivity
Antigens
Neoplasms
Immunocompetence
Cellular Immunity
Stroke
Skin

ASJC Scopus subject areas

  • Immunology and Allergy

Cite this

Delayed hypersensitivity responses of cancer patients to recall antigens using a new 'Multitest' applicator. / Reuben, J. M.; Hersh, Evan M.

In: Annals of Allergy, Vol. 53, No. 5, 1984, p. 390-394.

Research output: Contribution to journalArticle

@article{c745239050dd4e1b915b51c535b22a7d,
title = "Delayed hypersensitivity responses of cancer patients to recall antigens using a new 'Multitest' applicator",
abstract = "Testing of delayed-type hypersensitivity to recall antigens is acknowledged to be a useful assessment of cell-mediated immunity in cancer patients. The conventional method, however, has suffered from a lack of standardized antigens and variability owing to the method of application of the recall antigens. The Multitest-CMI system by the Merieux Institute offers an alternative. It employs standardized antigens and a single-stroke applicator, which is simpler to use and presumably subject to less variation. The present study compares the conventional and Multitest batteries done over an 8-month period in 403 cancer patients. The results suggest that the Multitest is easier to administer and is tolerated better by patients than the conventional method. Furthermore, the Multitest can detect recall antigen anergy or reactivity and correlates well in degrees of reactivity to the individual test battery. Consequently, Multitest-CMI can be substituted for the conventional battery in skin testing for immunocompetence in cancer patients.",
author = "Reuben, {J. M.} and Hersh, {Evan M}",
year = "1984",
language = "English (US)",
volume = "53",
pages = "390--394",
journal = "Annals of Allergy, Asthma and Immunology",
issn = "1081-1206",
publisher = "American College of Allergy, Asthma and Immunology",
number = "5",

}

TY - JOUR

T1 - Delayed hypersensitivity responses of cancer patients to recall antigens using a new 'Multitest' applicator

AU - Reuben, J. M.

AU - Hersh, Evan M

PY - 1984

Y1 - 1984

N2 - Testing of delayed-type hypersensitivity to recall antigens is acknowledged to be a useful assessment of cell-mediated immunity in cancer patients. The conventional method, however, has suffered from a lack of standardized antigens and variability owing to the method of application of the recall antigens. The Multitest-CMI system by the Merieux Institute offers an alternative. It employs standardized antigens and a single-stroke applicator, which is simpler to use and presumably subject to less variation. The present study compares the conventional and Multitest batteries done over an 8-month period in 403 cancer patients. The results suggest that the Multitest is easier to administer and is tolerated better by patients than the conventional method. Furthermore, the Multitest can detect recall antigen anergy or reactivity and correlates well in degrees of reactivity to the individual test battery. Consequently, Multitest-CMI can be substituted for the conventional battery in skin testing for immunocompetence in cancer patients.

AB - Testing of delayed-type hypersensitivity to recall antigens is acknowledged to be a useful assessment of cell-mediated immunity in cancer patients. The conventional method, however, has suffered from a lack of standardized antigens and variability owing to the method of application of the recall antigens. The Multitest-CMI system by the Merieux Institute offers an alternative. It employs standardized antigens and a single-stroke applicator, which is simpler to use and presumably subject to less variation. The present study compares the conventional and Multitest batteries done over an 8-month period in 403 cancer patients. The results suggest that the Multitest is easier to administer and is tolerated better by patients than the conventional method. Furthermore, the Multitest can detect recall antigen anergy or reactivity and correlates well in degrees of reactivity to the individual test battery. Consequently, Multitest-CMI can be substituted for the conventional battery in skin testing for immunocompetence in cancer patients.

UR - http://www.scopus.com/inward/record.url?scp=0021686955&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021686955&partnerID=8YFLogxK

M3 - Article

C2 - 6594072

AN - SCOPUS:0021686955

VL - 53

SP - 390

EP - 394

JO - Annals of Allergy, Asthma and Immunology

JF - Annals of Allergy, Asthma and Immunology

SN - 1081-1206

IS - 5

ER -