Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics

Jeong-Yeol Yoon, Brian C. Heinze, Jessica Gamboa, David J. You

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.

Original languageEnglish (US)
Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7313
DOIs
StatePublished - 2009
EventSmart Biomedical and Physiological Sensor Technology VI - Orlando, FL, United States
Duration: Apr 16 2009Apr 17 2009

Other

OtherSmart Biomedical and Physiological Sensor Technology VI
CountryUnited States
CityOrlando, FL
Period4/16/094/17/09

Fingerprint

influenza
Optical Fibers
Influenza in Birds
Microfluidics
Optical waveguides
antigens
Antigens
microchannels
Microchannels
optical waveguides
proximity
viruses
Viruses
Latex
beads
Light scattering
Lab-On-A-Chip Devices
Orthomyxoviridae
waveguides
Light

Keywords

  • Bird flu
  • Latex immunoagglutination assay
  • Light scattering
  • Optical fiber
  • Superhydrophobic surface

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Cite this

Yoon, J-Y., Heinze, B. C., Gamboa, J., & You, D. J. (2009). Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 7313). [73130J] https://doi.org/10.1117/12.817885

Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics. / Yoon, Jeong-Yeol; Heinze, Brian C.; Gamboa, Jessica; You, David J.

Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 7313 2009. 73130J.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yoon, J-Y, Heinze, BC, Gamboa, J & You, DJ 2009, Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics. in Progress in Biomedical Optics and Imaging - Proceedings of SPIE. vol. 7313, 73130J, Smart Biomedical and Physiological Sensor Technology VI, Orlando, FL, United States, 4/16/09. https://doi.org/10.1117/12.817885
Yoon J-Y, Heinze BC, Gamboa J, You DJ. Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 7313. 2009. 73130J https://doi.org/10.1117/12.817885
Yoon, Jeong-Yeol ; Heinze, Brian C. ; Gamboa, Jessica ; You, David J. / Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 7313 2009.
@inproceedings{408358cb0b9d4f51875a650d16020fe2,
title = "Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics",
abstract = "Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.",
keywords = "Bird flu, Latex immunoagglutination assay, Light scattering, Optical fiber, Superhydrophobic surface",
author = "Jeong-Yeol Yoon and Heinze, {Brian C.} and Jessica Gamboa and You, {David J.}",
year = "2009",
doi = "10.1117/12.817885",
language = "English (US)",
isbn = "9780819475794",
volume = "7313",
booktitle = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",

}

TY - GEN

T1 - Detection of avian influenza antigens in proximity fiber, droplet and optical waveguide microfluidics

AU - Yoon, Jeong-Yeol

AU - Heinze, Brian C.

AU - Gamboa, Jessica

AU - You, David J.

PY - 2009

Y1 - 2009

N2 - Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.

AB - Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.

KW - Bird flu

KW - Latex immunoagglutination assay

KW - Light scattering

KW - Optical fiber

KW - Superhydrophobic surface

UR - http://www.scopus.com/inward/record.url?scp=69849112218&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=69849112218&partnerID=8YFLogxK

U2 - 10.1117/12.817885

DO - 10.1117/12.817885

M3 - Conference contribution

AN - SCOPUS:69849112218

SN - 9780819475794

VL - 7313

BT - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

ER -