Dose-response study of the pathological effects of chronically applied direct current stimulation on the normal rat spinal cord

R. J. Hurlbert, C. H. Tator, E. Theriault

Research output: Contribution to journalArticle

27 Scopus citations

Abstract

Electrical stimulation of the mammalian central nervous system (CNS) can result in extensive destruction of tissue unless applied within specific stimulation parameters. Classically, unbalanced or monopolar currents have been avoided in order to minimize these harmful effects. However, direct current (DC) fields have recently been proposed for the treatment of spinal cord injury. Until now, no rigorous analysis has been made of the safety of these fields in the mammalian CNS. The purpose of this study was to determine the amount of chronically applied DC current that can be tolerated by the normal rodent spinal cord stimulated with metal disc electrodes. Thirty-five normal rats underwent implantation of DC stimulating devices and were allowed to recover for a period of 2 to 12 weeks. The stimulators delivered constant currents of 0 to 50 μA through two disc-shaped platinum/iridium electrodes positioned extradurally at the C-7 and T-3 levels. Following sacrifice of the animals, serial 8-μm cross sections of the spinal cord at the electrode sites were examined microscopically. Evidence of demyelination presumed due to the physical presence of the rostral electrode was seen in animals from most groups including control animals. Pathological changes directly attributable to the applied fields were seen with current as low as 3 μA. It was concluded that DC's of 3 μA or more are harmful to the mammalian CNS with this method of stimulation. In addition, the data suggest that the maximum current density tolerated by the rodent spinal cord is in the order of 75 μA/sq cm. These findings have important implications for the use of chronic DC stimulation in the mammalian CNS.

Original languageEnglish (US)
Pages (from-to)905-916
Number of pages12
JournalJournal of neurosurgery
Volume79
Issue number6
DOIs
StatePublished - Jan 1 1993
Externally publishedYes

Keywords

  • direct current field
  • electrical stimulation
  • rat
  • spinal cord injury
  • toxicity

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Fingerprint Dive into the research topics of 'Dose-response study of the pathological effects of chronically applied direct current stimulation on the normal rat spinal cord'. Together they form a unique fingerprint.