Abstract

Purpose: To measure eye motion in patients having laser in situ keratomileusis (LASIK) using a video technique and determine centration and variance of the eye position during surgery. Setting: Laser refractive surgery center. Methods: The procedure was videotaped in 5 consecutive eyes having LASIK performed by a single surgeon with the VISX Star S2 excimer laser. Following surgery, video images of the eyes were digitized and stored in a computer for processing. Digitized images were obtained at a rate of 25 images per second during the laser procedure. The pupil margin and a visual landmark, such as a scleral blood vessel, were identified in the initial image of each eye. Custom software was used to track the location of the landmark and the pupil center in subsequent images. Results: Three of the 5 eyes were well centered on average. The remaining 2 eyes were decentered inferiorly by approximately 0.25 mm. The standard deviation in all eyes was approximately 0.10 mm. Conclusions: With these techniques, the position of the entrance pupil center relative to the excimer laser axis could be determined. Although the system is not fast enough to be used during surgery, it does allow quantification of centration and intraoperative motion after surgery. (C) 2000 ASCRS and ESCRS.

Original languageEnglish (US)
Pages (from-to)345-351
Number of pages7
JournalJournal of Cataract and Refractive Surgery
Volume26
Issue number3
DOIs
StatePublished - Mar 2000

Fingerprint

Laser In Situ Keratomileusis
Eye Movements
Pupil
Excimer Lasers
Refractive Surgical Procedures
Laser Therapy
Blood Vessels
Lasers
Software

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Eye movement during laser in situ keratomileusis. / Schwiegerling, James T; Snyder, Robert W.

In: Journal of Cataract and Refractive Surgery, Vol. 26, No. 3, 03.2000, p. 345-351.

Research output: Contribution to journalArticle

@article{5458a822c1cf43c8ae02a002b33af117,
title = "Eye movement during laser in situ keratomileusis",
abstract = "Purpose: To measure eye motion in patients having laser in situ keratomileusis (LASIK) using a video technique and determine centration and variance of the eye position during surgery. Setting: Laser refractive surgery center. Methods: The procedure was videotaped in 5 consecutive eyes having LASIK performed by a single surgeon with the VISX Star S2 excimer laser. Following surgery, video images of the eyes were digitized and stored in a computer for processing. Digitized images were obtained at a rate of 25 images per second during the laser procedure. The pupil margin and a visual landmark, such as a scleral blood vessel, were identified in the initial image of each eye. Custom software was used to track the location of the landmark and the pupil center in subsequent images. Results: Three of the 5 eyes were well centered on average. The remaining 2 eyes were decentered inferiorly by approximately 0.25 mm. The standard deviation in all eyes was approximately 0.10 mm. Conclusions: With these techniques, the position of the entrance pupil center relative to the excimer laser axis could be determined. Although the system is not fast enough to be used during surgery, it does allow quantification of centration and intraoperative motion after surgery. (C) 2000 ASCRS and ESCRS.",
author = "Schwiegerling, {James T} and Snyder, {Robert W.}",
year = "2000",
month = "3",
doi = "10.1016/S0886-3350(99)00435-6",
language = "English (US)",
volume = "26",
pages = "345--351",
journal = "Journal of Cataract and Refractive Surgery",
issn = "0886-3350",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - Eye movement during laser in situ keratomileusis

AU - Schwiegerling, James T

AU - Snyder, Robert W.

PY - 2000/3

Y1 - 2000/3

N2 - Purpose: To measure eye motion in patients having laser in situ keratomileusis (LASIK) using a video technique and determine centration and variance of the eye position during surgery. Setting: Laser refractive surgery center. Methods: The procedure was videotaped in 5 consecutive eyes having LASIK performed by a single surgeon with the VISX Star S2 excimer laser. Following surgery, video images of the eyes were digitized and stored in a computer for processing. Digitized images were obtained at a rate of 25 images per second during the laser procedure. The pupil margin and a visual landmark, such as a scleral blood vessel, were identified in the initial image of each eye. Custom software was used to track the location of the landmark and the pupil center in subsequent images. Results: Three of the 5 eyes were well centered on average. The remaining 2 eyes were decentered inferiorly by approximately 0.25 mm. The standard deviation in all eyes was approximately 0.10 mm. Conclusions: With these techniques, the position of the entrance pupil center relative to the excimer laser axis could be determined. Although the system is not fast enough to be used during surgery, it does allow quantification of centration and intraoperative motion after surgery. (C) 2000 ASCRS and ESCRS.

AB - Purpose: To measure eye motion in patients having laser in situ keratomileusis (LASIK) using a video technique and determine centration and variance of the eye position during surgery. Setting: Laser refractive surgery center. Methods: The procedure was videotaped in 5 consecutive eyes having LASIK performed by a single surgeon with the VISX Star S2 excimer laser. Following surgery, video images of the eyes were digitized and stored in a computer for processing. Digitized images were obtained at a rate of 25 images per second during the laser procedure. The pupil margin and a visual landmark, such as a scleral blood vessel, were identified in the initial image of each eye. Custom software was used to track the location of the landmark and the pupil center in subsequent images. Results: Three of the 5 eyes were well centered on average. The remaining 2 eyes were decentered inferiorly by approximately 0.25 mm. The standard deviation in all eyes was approximately 0.10 mm. Conclusions: With these techniques, the position of the entrance pupil center relative to the excimer laser axis could be determined. Although the system is not fast enough to be used during surgery, it does allow quantification of centration and intraoperative motion after surgery. (C) 2000 ASCRS and ESCRS.

UR - http://www.scopus.com/inward/record.url?scp=0034019942&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034019942&partnerID=8YFLogxK

U2 - 10.1016/S0886-3350(99)00435-6

DO - 10.1016/S0886-3350(99)00435-6

M3 - Article

VL - 26

SP - 345

EP - 351

JO - Journal of Cataract and Refractive Surgery

JF - Journal of Cataract and Refractive Surgery

SN - 0886-3350

IS - 3

ER -