We demonstrate an amplifier based on the Wheatstone bridge designed specifically for use in single molecule break junctions. This amplifier exhibits superior performance due to its large bandwidth, flat frequency response, and high sensitivity. The amplifier is capable of measuring conductance values from 102 to 10−6G0 (G0 = 2e2/h), while maintaining a bandwidth in excess of 20 kHz, and shows remarkable resolution in the molecular conductance regime of 10−2 to 10−5 G0.

Original languageEnglish (US)
Article number033904
JournalReview of Scientific Instruments
Volume88
Issue number3
DOIs
StatePublished - Mar 1 2017

Fingerprint

amplifiers
Bandwidth
Molecules
probes
Frequency response
Wheatstone bridges
bandwidth
molecules
frequency response
sensitivity

ASJC Scopus subject areas

  • Instrumentation

Cite this

Fast sensitive amplifier for two-probe conductance measurements in single molecule break junctions. / Johnson, Tyler K.; Ivie, Jeffrey A.; Jaruvang, Jason; Monti Masel, Oliver L A.

In: Review of Scientific Instruments, Vol. 88, No. 3, 033904, 01.03.2017.

Research output: Contribution to journalArticle

@article{808c26b63b794abaa05f9f50b45eb936,
title = "Fast sensitive amplifier for two-probe conductance measurements in single molecule break junctions",
abstract = "We demonstrate an amplifier based on the Wheatstone bridge designed specifically for use in single molecule break junctions. This amplifier exhibits superior performance due to its large bandwidth, flat frequency response, and high sensitivity. The amplifier is capable of measuring conductance values from 102 to 10−6G0 (G0 = 2e2/h), while maintaining a bandwidth in excess of 20 kHz, and shows remarkable resolution in the molecular conductance regime of 10−2 to 10−5 G0.",
author = "Johnson, {Tyler K.} and Ivie, {Jeffrey A.} and Jason Jaruvang and {Monti Masel}, {Oliver L A}",
year = "2017",
month = "3",
day = "1",
doi = "10.1063/1.4978962",
language = "English (US)",
volume = "88",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "3",

}

TY - JOUR

T1 - Fast sensitive amplifier for two-probe conductance measurements in single molecule break junctions

AU - Johnson, Tyler K.

AU - Ivie, Jeffrey A.

AU - Jaruvang, Jason

AU - Monti Masel, Oliver L A

PY - 2017/3/1

Y1 - 2017/3/1

N2 - We demonstrate an amplifier based on the Wheatstone bridge designed specifically for use in single molecule break junctions. This amplifier exhibits superior performance due to its large bandwidth, flat frequency response, and high sensitivity. The amplifier is capable of measuring conductance values from 102 to 10−6G0 (G0 = 2e2/h), while maintaining a bandwidth in excess of 20 kHz, and shows remarkable resolution in the molecular conductance regime of 10−2 to 10−5 G0.

AB - We demonstrate an amplifier based on the Wheatstone bridge designed specifically for use in single molecule break junctions. This amplifier exhibits superior performance due to its large bandwidth, flat frequency response, and high sensitivity. The amplifier is capable of measuring conductance values from 102 to 10−6G0 (G0 = 2e2/h), while maintaining a bandwidth in excess of 20 kHz, and shows remarkable resolution in the molecular conductance regime of 10−2 to 10−5 G0.

UR - http://www.scopus.com/inward/record.url?scp=85016408650&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85016408650&partnerID=8YFLogxK

U2 - 10.1063/1.4978962

DO - 10.1063/1.4978962

M3 - Article

VL - 88

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 3

M1 - 033904

ER -