Fetal pulmonary artery and aorta: Two-dimensional Doppler echocardiography

Kathryn L Reed, C. F. Anderson, L. Shenker

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Two-dimensional and pulsed Doppler ultrasound techniques were used to examine 87 fetuses between 17 and 41 weeks' gestation in order to compare pulmonary artery and aortic outflow diameters, mean and maximal flow velocities, and transvalve flows. For purposes of analysis, fetuses were divided into two groups: those less than 31 weeks, and those of 31 weeks or more. Diameters of the pulmonary artery and aortic outflow region increased with advancing gestational age (P<.001), while mean and maximal Doppler flow velocities did not change. Transvalve volume flow increased across both regions (pulmonary artery from 381 ± 12 mL/minute to 530 ± 13 mL/minute and aortic outflow from 286 ± 10 mL/minute to 410 ± 13 mL/minute, P<.001) with advancing gestation. Pulmonary artery diameters were larger than aortic outflow diameters in both groups (P<.01), while mean Doppler flow velocities were not significantly different. Maximal Doppler flow velocities were greater in the aorta than in the pulmonary artery (P<.001), and transvalve flow was greater across the pulmonary artery than the aorta in both groups (P<.05, ratio 1.3:1). This work demonstrates differences in fetal pulmonary artery and aortic outflow anatomy and physiology that must be considered in evaluating studies of fetal cardiac physiology.

Original languageEnglish (US)
Pages (from-to)175-178
Number of pages4
JournalObstetrics and Gynecology
Volume69
Issue number2
StatePublished - 1987

Fingerprint

Doppler Echocardiography
Pulmonary Artery
Aorta
Fetus
Doppler Ultrasonography
Pregnancy
Gestational Age
Anatomy

ASJC Scopus subject areas

  • Obstetrics and Gynecology

Cite this

Fetal pulmonary artery and aorta : Two-dimensional Doppler echocardiography. / Reed, Kathryn L; Anderson, C. F.; Shenker, L.

In: Obstetrics and Gynecology, Vol. 69, No. 2, 1987, p. 175-178.

Research output: Contribution to journalArticle

Reed, Kathryn L ; Anderson, C. F. ; Shenker, L. / Fetal pulmonary artery and aorta : Two-dimensional Doppler echocardiography. In: Obstetrics and Gynecology. 1987 ; Vol. 69, No. 2. pp. 175-178.
@article{6dd9394c693c4f06a6eb78c0e9473f49,
title = "Fetal pulmonary artery and aorta: Two-dimensional Doppler echocardiography",
abstract = "Two-dimensional and pulsed Doppler ultrasound techniques were used to examine 87 fetuses between 17 and 41 weeks' gestation in order to compare pulmonary artery and aortic outflow diameters, mean and maximal flow velocities, and transvalve flows. For purposes of analysis, fetuses were divided into two groups: those less than 31 weeks, and those of 31 weeks or more. Diameters of the pulmonary artery and aortic outflow region increased with advancing gestational age (P<.001), while mean and maximal Doppler flow velocities did not change. Transvalve volume flow increased across both regions (pulmonary artery from 381 ± 12 mL/minute to 530 ± 13 mL/minute and aortic outflow from 286 ± 10 mL/minute to 410 ± 13 mL/minute, P<.001) with advancing gestation. Pulmonary artery diameters were larger than aortic outflow diameters in both groups (P<.01), while mean Doppler flow velocities were not significantly different. Maximal Doppler flow velocities were greater in the aorta than in the pulmonary artery (P<.001), and transvalve flow was greater across the pulmonary artery than the aorta in both groups (P<.05, ratio 1.3:1). This work demonstrates differences in fetal pulmonary artery and aortic outflow anatomy and physiology that must be considered in evaluating studies of fetal cardiac physiology.",
author = "Reed, {Kathryn L} and Anderson, {C. F.} and L. Shenker",
year = "1987",
language = "English (US)",
volume = "69",
pages = "175--178",
journal = "Obstetrics and Gynecology",
issn = "0029-7844",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Fetal pulmonary artery and aorta

T2 - Two-dimensional Doppler echocardiography

AU - Reed, Kathryn L

AU - Anderson, C. F.

AU - Shenker, L.

PY - 1987

Y1 - 1987

N2 - Two-dimensional and pulsed Doppler ultrasound techniques were used to examine 87 fetuses between 17 and 41 weeks' gestation in order to compare pulmonary artery and aortic outflow diameters, mean and maximal flow velocities, and transvalve flows. For purposes of analysis, fetuses were divided into two groups: those less than 31 weeks, and those of 31 weeks or more. Diameters of the pulmonary artery and aortic outflow region increased with advancing gestational age (P<.001), while mean and maximal Doppler flow velocities did not change. Transvalve volume flow increased across both regions (pulmonary artery from 381 ± 12 mL/minute to 530 ± 13 mL/minute and aortic outflow from 286 ± 10 mL/minute to 410 ± 13 mL/minute, P<.001) with advancing gestation. Pulmonary artery diameters were larger than aortic outflow diameters in both groups (P<.01), while mean Doppler flow velocities were not significantly different. Maximal Doppler flow velocities were greater in the aorta than in the pulmonary artery (P<.001), and transvalve flow was greater across the pulmonary artery than the aorta in both groups (P<.05, ratio 1.3:1). This work demonstrates differences in fetal pulmonary artery and aortic outflow anatomy and physiology that must be considered in evaluating studies of fetal cardiac physiology.

AB - Two-dimensional and pulsed Doppler ultrasound techniques were used to examine 87 fetuses between 17 and 41 weeks' gestation in order to compare pulmonary artery and aortic outflow diameters, mean and maximal flow velocities, and transvalve flows. For purposes of analysis, fetuses were divided into two groups: those less than 31 weeks, and those of 31 weeks or more. Diameters of the pulmonary artery and aortic outflow region increased with advancing gestational age (P<.001), while mean and maximal Doppler flow velocities did not change. Transvalve volume flow increased across both regions (pulmonary artery from 381 ± 12 mL/minute to 530 ± 13 mL/minute and aortic outflow from 286 ± 10 mL/minute to 410 ± 13 mL/minute, P<.001) with advancing gestation. Pulmonary artery diameters were larger than aortic outflow diameters in both groups (P<.01), while mean Doppler flow velocities were not significantly different. Maximal Doppler flow velocities were greater in the aorta than in the pulmonary artery (P<.001), and transvalve flow was greater across the pulmonary artery than the aorta in both groups (P<.05, ratio 1.3:1). This work demonstrates differences in fetal pulmonary artery and aortic outflow anatomy and physiology that must be considered in evaluating studies of fetal cardiac physiology.

UR - http://www.scopus.com/inward/record.url?scp=0023118765&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023118765&partnerID=8YFLogxK

M3 - Article

C2 - 3808503

AN - SCOPUS:0023118765

VL - 69

SP - 175

EP - 178

JO - Obstetrics and Gynecology

JF - Obstetrics and Gynecology

SN - 0029-7844

IS - 2

ER -