In very-high-spatial-resolution gamma-ray imaging applications, such as preclinical PET and SPECT, estimation of 3D interaction location inside the detector crystal can be used to minimize parallax error in the imaging system. In this work, we investigate the effect of bias voltage setting on depth-of-interaction (DOI) estimates for a semiconductor detector with a double-sided strip geometry. We first examine the statistical properties of the signals and develop expressions for likelihoods for given gamma-ray interaction positions. We use Fisher Information to quantify how well (in terms of variance) the measured signals can be used for DOI estimation with different bias-voltage settings. We performed measurements of detector response versus 3D position as a function of applied bias voltage by scanning with highly collimated synchrotron radiation at the Advanced Photon Source at Argonne National Laboratory. Experimental and theoretical results show that the optimum bias setting depends on whether or not the estimated event position will include the depth of interaction. We also found that for this detector geometry, the z-resolution changes with depth.

Original languageEnglish (US)
Article number6819048
Pages (from-to)1243-1251
Number of pages9
JournalIEEE Transactions on Nuclear Science
Volume61
Issue number3
DOIs
StatePublished - 2014

Fingerprint

information analysis
Fisher information
Information analysis
Bias voltage
strip
Detectors
Gamma rays
detectors
Semiconductor detectors
Geometry
interactions
Synchrotron radiation
electric potential
Imaging systems
gamma rays
Photons
parallax
Scanning
Imaging techniques
geometry

Keywords

  • CdTe
  • CdZnTe
  • DOI
  • double-sided strip
  • Fisher Information
  • semiconductor detectors

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Nuclear Energy and Engineering
  • Nuclear and High Energy Physics

Cite this

Fisher information analysis of depth-of-interaction estimation in double-sided strip detectors. / Salcin, Esen; Barrett, Harrison H; Barber, H. Bradford; Takeda, Shinrichiro; Watanabe, Shin; Takahashi, Tadayuki; Furenlid, Lars R.

In: IEEE Transactions on Nuclear Science, Vol. 61, No. 3, 6819048, 2014, p. 1243-1251.

Research output: Contribution to journalArticle

Salcin, Esen ; Barrett, Harrison H ; Barber, H. Bradford ; Takeda, Shinrichiro ; Watanabe, Shin ; Takahashi, Tadayuki ; Furenlid, Lars R. / Fisher information analysis of depth-of-interaction estimation in double-sided strip detectors. In: IEEE Transactions on Nuclear Science. 2014 ; Vol. 61, No. 3. pp. 1243-1251.
@article{1bfd366b2fb84fbb9ea18057c0dde893,
title = "Fisher information analysis of depth-of-interaction estimation in double-sided strip detectors",
abstract = "In very-high-spatial-resolution gamma-ray imaging applications, such as preclinical PET and SPECT, estimation of 3D interaction location inside the detector crystal can be used to minimize parallax error in the imaging system. In this work, we investigate the effect of bias voltage setting on depth-of-interaction (DOI) estimates for a semiconductor detector with a double-sided strip geometry. We first examine the statistical properties of the signals and develop expressions for likelihoods for given gamma-ray interaction positions. We use Fisher Information to quantify how well (in terms of variance) the measured signals can be used for DOI estimation with different bias-voltage settings. We performed measurements of detector response versus 3D position as a function of applied bias voltage by scanning with highly collimated synchrotron radiation at the Advanced Photon Source at Argonne National Laboratory. Experimental and theoretical results show that the optimum bias setting depends on whether or not the estimated event position will include the depth of interaction. We also found that for this detector geometry, the z-resolution changes with depth.",
keywords = "CdTe, CdZnTe, DOI, double-sided strip, Fisher Information, semiconductor detectors",
author = "Esen Salcin and Barrett, {Harrison H} and Barber, {H. Bradford} and Shinrichiro Takeda and Shin Watanabe and Tadayuki Takahashi and Furenlid, {Lars R}",
year = "2014",
doi = "10.1109/TNS.2014.2317454",
language = "English (US)",
volume = "61",
pages = "1243--1251",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

TY - JOUR

T1 - Fisher information analysis of depth-of-interaction estimation in double-sided strip detectors

AU - Salcin, Esen

AU - Barrett, Harrison H

AU - Barber, H. Bradford

AU - Takeda, Shinrichiro

AU - Watanabe, Shin

AU - Takahashi, Tadayuki

AU - Furenlid, Lars R

PY - 2014

Y1 - 2014

N2 - In very-high-spatial-resolution gamma-ray imaging applications, such as preclinical PET and SPECT, estimation of 3D interaction location inside the detector crystal can be used to minimize parallax error in the imaging system. In this work, we investigate the effect of bias voltage setting on depth-of-interaction (DOI) estimates for a semiconductor detector with a double-sided strip geometry. We first examine the statistical properties of the signals and develop expressions for likelihoods for given gamma-ray interaction positions. We use Fisher Information to quantify how well (in terms of variance) the measured signals can be used for DOI estimation with different bias-voltage settings. We performed measurements of detector response versus 3D position as a function of applied bias voltage by scanning with highly collimated synchrotron radiation at the Advanced Photon Source at Argonne National Laboratory. Experimental and theoretical results show that the optimum bias setting depends on whether or not the estimated event position will include the depth of interaction. We also found that for this detector geometry, the z-resolution changes with depth.

AB - In very-high-spatial-resolution gamma-ray imaging applications, such as preclinical PET and SPECT, estimation of 3D interaction location inside the detector crystal can be used to minimize parallax error in the imaging system. In this work, we investigate the effect of bias voltage setting on depth-of-interaction (DOI) estimates for a semiconductor detector with a double-sided strip geometry. We first examine the statistical properties of the signals and develop expressions for likelihoods for given gamma-ray interaction positions. We use Fisher Information to quantify how well (in terms of variance) the measured signals can be used for DOI estimation with different bias-voltage settings. We performed measurements of detector response versus 3D position as a function of applied bias voltage by scanning with highly collimated synchrotron radiation at the Advanced Photon Source at Argonne National Laboratory. Experimental and theoretical results show that the optimum bias setting depends on whether or not the estimated event position will include the depth of interaction. We also found that for this detector geometry, the z-resolution changes with depth.

KW - CdTe

KW - CdZnTe

KW - DOI

KW - double-sided strip

KW - Fisher Information

KW - semiconductor detectors

UR - http://www.scopus.com/inward/record.url?scp=84903315603&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84903315603&partnerID=8YFLogxK

U2 - 10.1109/TNS.2014.2317454

DO - 10.1109/TNS.2014.2317454

M3 - Article

AN - SCOPUS:84903315603

VL - 61

SP - 1243

EP - 1251

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 3

M1 - 6819048

ER -