Full-Stokes imaging polarimeter using an array of elliptical polarizer

Wei Liang Hsu, Graham Myhre, Kaushik Balakrishnan, Neal Brock, Mohammed Ibn-Elhaj, Stanley K H Pau

Research output: Contribution to journalArticle

58 Citations (Scopus)

Abstract

In this paper, a full-Stokes imaging polarimeter operating at 580 nm using an array of elliptical polarizers is presented. The division-of-focal-plane polarimeter utilizes a set of four optimized measurements which represent a regular tetrahedron inscribed in the Poincaré sphere. Results from the device fabrication, instrument calibration and characterization are presented. The performance of the optimized full Stokes polarimeter, as defined by size of the standard deviation of the degree of circular polarization, is found to be approximately five times better than the performance of the simple full-Stokes polarimeter.

Original languageEnglish (US)
Pages (from-to)3063-3074
Number of pages12
JournalOptics Express
Volume22
Issue number3
DOIs
StatePublished - Feb 10 2014

Fingerprint

polarimeters
polarizers
circular polarization
tetrahedrons
division
standard deviation
fabrication

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Full-Stokes imaging polarimeter using an array of elliptical polarizer. / Hsu, Wei Liang; Myhre, Graham; Balakrishnan, Kaushik; Brock, Neal; Ibn-Elhaj, Mohammed; Pau, Stanley K H.

In: Optics Express, Vol. 22, No. 3, 10.02.2014, p. 3063-3074.

Research output: Contribution to journalArticle

Hsu, Wei Liang ; Myhre, Graham ; Balakrishnan, Kaushik ; Brock, Neal ; Ibn-Elhaj, Mohammed ; Pau, Stanley K H. / Full-Stokes imaging polarimeter using an array of elliptical polarizer. In: Optics Express. 2014 ; Vol. 22, No. 3. pp. 3063-3074.
@article{c61d6de652854c7ca952fe6dd092b25b,
title = "Full-Stokes imaging polarimeter using an array of elliptical polarizer",
abstract = "In this paper, a full-Stokes imaging polarimeter operating at 580 nm using an array of elliptical polarizers is presented. The division-of-focal-plane polarimeter utilizes a set of four optimized measurements which represent a regular tetrahedron inscribed in the Poincar{\'e} sphere. Results from the device fabrication, instrument calibration and characterization are presented. The performance of the optimized full Stokes polarimeter, as defined by size of the standard deviation of the degree of circular polarization, is found to be approximately five times better than the performance of the simple full-Stokes polarimeter.",
author = "Hsu, {Wei Liang} and Graham Myhre and Kaushik Balakrishnan and Neal Brock and Mohammed Ibn-Elhaj and Pau, {Stanley K H}",
year = "2014",
month = "2",
day = "10",
doi = "10.1364/OE.22.003063",
language = "English (US)",
volume = "22",
pages = "3063--3074",
journal = "Optics Express",
issn = "1094-4087",
publisher = "The Optical Society",
number = "3",

}

TY - JOUR

T1 - Full-Stokes imaging polarimeter using an array of elliptical polarizer

AU - Hsu, Wei Liang

AU - Myhre, Graham

AU - Balakrishnan, Kaushik

AU - Brock, Neal

AU - Ibn-Elhaj, Mohammed

AU - Pau, Stanley K H

PY - 2014/2/10

Y1 - 2014/2/10

N2 - In this paper, a full-Stokes imaging polarimeter operating at 580 nm using an array of elliptical polarizers is presented. The division-of-focal-plane polarimeter utilizes a set of four optimized measurements which represent a regular tetrahedron inscribed in the Poincaré sphere. Results from the device fabrication, instrument calibration and characterization are presented. The performance of the optimized full Stokes polarimeter, as defined by size of the standard deviation of the degree of circular polarization, is found to be approximately five times better than the performance of the simple full-Stokes polarimeter.

AB - In this paper, a full-Stokes imaging polarimeter operating at 580 nm using an array of elliptical polarizers is presented. The division-of-focal-plane polarimeter utilizes a set of four optimized measurements which represent a regular tetrahedron inscribed in the Poincaré sphere. Results from the device fabrication, instrument calibration and characterization are presented. The performance of the optimized full Stokes polarimeter, as defined by size of the standard deviation of the degree of circular polarization, is found to be approximately five times better than the performance of the simple full-Stokes polarimeter.

UR - http://www.scopus.com/inward/record.url?scp=84893901356&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893901356&partnerID=8YFLogxK

U2 - 10.1364/OE.22.003063

DO - 10.1364/OE.22.003063

M3 - Article

AN - SCOPUS:84893901356

VL - 22

SP - 3063

EP - 3074

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 3

ER -