High numerical aperture line scanning system

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

In order to scan a line, the scanning optics usually employs either NSG's SELFOC lens or a 1:1 lenslet array. Each of these two methods has its limitation. The SELFOC lens' numerical aperture (NA) is low, which limits its light-collection efficiency. A 1:1 lenslet array can have a high NA, but its resolution along the scanning direction is low, which means it is not suitable for 2-D scanning. In this paper, line scan optics with a high NA will be discussed. Unlike the above-mentioned methods, this method has the same high resolution in both line and scan directions. It has a 1:-1 (preferred 1:<-1) relationship between the object and the image. A number of groups of lenses, based on the length of the object, is required and are arranged along a single plane. The field of each group is equal to or slightly larger than the diameter of the lens. Each group of lenses images a segment of the object onto the image plane. The magnification of each group should be less than 1:-1, for example, 1:-0.95, so that the image of each segment will not overlap in the sensor when one long sensor is used, or it will not be larger than the sensor when each group has its own sensor. After the image of each segment is read from the sensor, it is reverted and, with the help of image processing, all of the images are connected together to form an image of the whole line.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
Volume6668
DOIs
StatePublished - 2007
Externally publishedYes
Event10th Conference of Novel Optical Systems Design and Optimization - San Diego, CA, United States
Duration: Aug 28 2007Aug 29 2007

Other

Other10th Conference of Novel Optical Systems Design and Optimization
CountryUnited States
CitySan Diego, CA
Period8/28/078/29/07

Fingerprint

numerical aperture
Lenses
Scanning
scanning
Sensors
lenses
sensors
Optics
optics
Image processing
magnification
image processing
high resolution

Keywords

  • Lenslet array
  • Line imaging
  • Line scanning
  • Scanning optics

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Cite this

Liang, R. (2007). High numerical aperture line scanning system. In Proceedings of SPIE - The International Society for Optical Engineering (Vol. 6668). [66680I] https://doi.org/10.1117/12.727615

High numerical aperture line scanning system. / Liang, Rongguang.

Proceedings of SPIE - The International Society for Optical Engineering. Vol. 6668 2007. 66680I.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Liang, R 2007, High numerical aperture line scanning system. in Proceedings of SPIE - The International Society for Optical Engineering. vol. 6668, 66680I, 10th Conference of Novel Optical Systems Design and Optimization, San Diego, CA, United States, 8/28/07. https://doi.org/10.1117/12.727615
Liang R. High numerical aperture line scanning system. In Proceedings of SPIE - The International Society for Optical Engineering. Vol. 6668. 2007. 66680I https://doi.org/10.1117/12.727615
Liang, Rongguang. / High numerical aperture line scanning system. Proceedings of SPIE - The International Society for Optical Engineering. Vol. 6668 2007.
@inproceedings{1ec792c9799c4ed39b8d40c776852d89,
title = "High numerical aperture line scanning system",
abstract = "In order to scan a line, the scanning optics usually employs either NSG's SELFOC lens or a 1:1 lenslet array. Each of these two methods has its limitation. The SELFOC lens' numerical aperture (NA) is low, which limits its light-collection efficiency. A 1:1 lenslet array can have a high NA, but its resolution along the scanning direction is low, which means it is not suitable for 2-D scanning. In this paper, line scan optics with a high NA will be discussed. Unlike the above-mentioned methods, this method has the same high resolution in both line and scan directions. It has a 1:-1 (preferred 1:<-1) relationship between the object and the image. A number of groups of lenses, based on the length of the object, is required and are arranged along a single plane. The field of each group is equal to or slightly larger than the diameter of the lens. Each group of lenses images a segment of the object onto the image plane. The magnification of each group should be less than 1:-1, for example, 1:-0.95, so that the image of each segment will not overlap in the sensor when one long sensor is used, or it will not be larger than the sensor when each group has its own sensor. After the image of each segment is read from the sensor, it is reverted and, with the help of image processing, all of the images are connected together to form an image of the whole line.",
keywords = "Lenslet array, Line imaging, Line scanning, Scanning optics",
author = "Rongguang Liang",
year = "2007",
doi = "10.1117/12.727615",
language = "English (US)",
isbn = "9780819468161",
volume = "6668",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",

}

TY - GEN

T1 - High numerical aperture line scanning system

AU - Liang, Rongguang

PY - 2007

Y1 - 2007

N2 - In order to scan a line, the scanning optics usually employs either NSG's SELFOC lens or a 1:1 lenslet array. Each of these two methods has its limitation. The SELFOC lens' numerical aperture (NA) is low, which limits its light-collection efficiency. A 1:1 lenslet array can have a high NA, but its resolution along the scanning direction is low, which means it is not suitable for 2-D scanning. In this paper, line scan optics with a high NA will be discussed. Unlike the above-mentioned methods, this method has the same high resolution in both line and scan directions. It has a 1:-1 (preferred 1:<-1) relationship between the object and the image. A number of groups of lenses, based on the length of the object, is required and are arranged along a single plane. The field of each group is equal to or slightly larger than the diameter of the lens. Each group of lenses images a segment of the object onto the image plane. The magnification of each group should be less than 1:-1, for example, 1:-0.95, so that the image of each segment will not overlap in the sensor when one long sensor is used, or it will not be larger than the sensor when each group has its own sensor. After the image of each segment is read from the sensor, it is reverted and, with the help of image processing, all of the images are connected together to form an image of the whole line.

AB - In order to scan a line, the scanning optics usually employs either NSG's SELFOC lens or a 1:1 lenslet array. Each of these two methods has its limitation. The SELFOC lens' numerical aperture (NA) is low, which limits its light-collection efficiency. A 1:1 lenslet array can have a high NA, but its resolution along the scanning direction is low, which means it is not suitable for 2-D scanning. In this paper, line scan optics with a high NA will be discussed. Unlike the above-mentioned methods, this method has the same high resolution in both line and scan directions. It has a 1:-1 (preferred 1:<-1) relationship between the object and the image. A number of groups of lenses, based on the length of the object, is required and are arranged along a single plane. The field of each group is equal to or slightly larger than the diameter of the lens. Each group of lenses images a segment of the object onto the image plane. The magnification of each group should be less than 1:-1, for example, 1:-0.95, so that the image of each segment will not overlap in the sensor when one long sensor is used, or it will not be larger than the sensor when each group has its own sensor. After the image of each segment is read from the sensor, it is reverted and, with the help of image processing, all of the images are connected together to form an image of the whole line.

KW - Lenslet array

KW - Line imaging

KW - Line scanning

KW - Scanning optics

UR - http://www.scopus.com/inward/record.url?scp=42149134164&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=42149134164&partnerID=8YFLogxK

U2 - 10.1117/12.727615

DO - 10.1117/12.727615

M3 - Conference contribution

AN - SCOPUS:42149134164

SN - 9780819468161

VL - 6668

BT - Proceedings of SPIE - The International Society for Optical Engineering

ER -