Image quality of CRT displays and the effect of brightness on diagnosis of mammograms

Hans Roehrig, Elizabeth A Krupinski

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Measurements were conducted on two cathode ray tube (CRT) displays to determine the image quality of the displays, particularly the display function and the squarewave response. The influence of image quality on diagnosis in mammography was determined by observer performance studies at different CRT maximum luminance values. Maximum luminance was observed to affect the observer performance.

Original languageEnglish (US)
JournalJournal of Digital Imaging
Volume11
Issue number3 Suppl 1
StatePublished - Aug 1998

Fingerprint

Cathode Ray Tube
Cathode ray tubes
Image quality
Luminance
Display devices
Mammography

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Image quality of CRT displays and the effect of brightness on diagnosis of mammograms. / Roehrig, Hans; Krupinski, Elizabeth A.

In: Journal of Digital Imaging, Vol. 11, No. 3 Suppl 1, 08.1998.

Research output: Contribution to journalArticle

@article{359e0326d0c4427ab10da28940743f93,
title = "Image quality of CRT displays and the effect of brightness on diagnosis of mammograms",
abstract = "Measurements were conducted on two cathode ray tube (CRT) displays to determine the image quality of the displays, particularly the display function and the squarewave response. The influence of image quality on diagnosis in mammography was determined by observer performance studies at different CRT maximum luminance values. Maximum luminance was observed to affect the observer performance.",
author = "Hans Roehrig and Krupinski, {Elizabeth A}",
year = "1998",
month = "8",
language = "English (US)",
volume = "11",
journal = "Journal of Digital Imaging",
issn = "0897-1889",
publisher = "Springer New York",
number = "3 Suppl 1",

}

TY - JOUR

T1 - Image quality of CRT displays and the effect of brightness on diagnosis of mammograms

AU - Roehrig, Hans

AU - Krupinski, Elizabeth A

PY - 1998/8

Y1 - 1998/8

N2 - Measurements were conducted on two cathode ray tube (CRT) displays to determine the image quality of the displays, particularly the display function and the squarewave response. The influence of image quality on diagnosis in mammography was determined by observer performance studies at different CRT maximum luminance values. Maximum luminance was observed to affect the observer performance.

AB - Measurements were conducted on two cathode ray tube (CRT) displays to determine the image quality of the displays, particularly the display function and the squarewave response. The influence of image quality on diagnosis in mammography was determined by observer performance studies at different CRT maximum luminance values. Maximum luminance was observed to affect the observer performance.

UR - http://www.scopus.com/inward/record.url?scp=0032129258&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032129258&partnerID=8YFLogxK

M3 - Article

C2 - 9735465

AN - SCOPUS:0032129258

VL - 11

JO - Journal of Digital Imaging

JF - Journal of Digital Imaging

SN - 0897-1889

IS - 3 Suppl 1

ER -