Improved Calibration of Voltammetric Sensors for Studying Pharmacological Effects on Dopamine Transporter Kinetics in Vivo

Christopher W. Atcherley, Nicholas D. Laude, Eric B. Monroe, Kevin M. Wood, Parastoo Hashemi, Michael L Heien

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

The distribution and density of neurons within the brain poses many challenges when making quantitative measurements of neurotransmission in the extracellular space. A volume neurotransmitter is released into the synapse during chemical communication and must diffuse through the extracellular space to an implanted sensor for real-time in situ detection. Fast-scan cyclic voltammetry is an excellent technique for measuring biologically relevant concentration changes in vivo; however, the sensitivity is limited by mass-transport-limited adsorption. Due to the resistance to mass transfer in the brain, the response time of voltammetric sensors is increased, which decreases the sensitivity and the temporal fidelity of the measurement. Here, experimental results reveal how the tortuosity of the extracellular space affects the response of the electrode. Additionally, a model of mass-transport-limited adsorption is utilized to account for both the strength of adsorption and the magnitude of the diffusion coefficient to calculate the response time of the electrode. The response time is then used to determine the concentration of dopamine released in response to salient stimuli. We present the method of kinetic calibration of in vivo voltammetric data and apply the method to discern changes in the K<inf>M</inf> for the murine dopamine transporter. The K<inf>M</inf> increased from 0.32 ± 0.08 μM (n = 3 animals) prior to drug administration to 2.72 ± 0.37 μM (n = 3 animals) after treatment with GBR-12909.

Original languageEnglish (US)
Pages (from-to)1509-1516
Number of pages8
JournalACS Chemical Neuroscience
Volume6
Issue number9
DOIs
StatePublished - Jul 25 2014

Fingerprint

Dopamine Plasma Membrane Transport Proteins
Extracellular Space
Calibration
Adsorption
Reaction Time
Mass transfer
Pharmacology
Kinetics
Brain
Sensors
Electrodes
Animals
Synaptic Transmission
Synapses
Cyclic voltammetry
Neurons
Neurotransmitter Agents
Dopamine
Communication
Pharmaceutical Preparations

Keywords

  • calibration
  • Dopamine
  • electrochemistry
  • hindered diffusion
  • in vivo
  • kinetics

ASJC Scopus subject areas

  • Biochemistry
  • Cell Biology
  • Physiology
  • Cognitive Neuroscience

Cite this

Improved Calibration of Voltammetric Sensors for Studying Pharmacological Effects on Dopamine Transporter Kinetics in Vivo. / Atcherley, Christopher W.; Laude, Nicholas D.; Monroe, Eric B.; Wood, Kevin M.; Hashemi, Parastoo; Heien, Michael L.

In: ACS Chemical Neuroscience, Vol. 6, No. 9, 25.07.2014, p. 1509-1516.

Research output: Contribution to journalArticle

Atcherley, Christopher W. ; Laude, Nicholas D. ; Monroe, Eric B. ; Wood, Kevin M. ; Hashemi, Parastoo ; Heien, Michael L. / Improved Calibration of Voltammetric Sensors for Studying Pharmacological Effects on Dopamine Transporter Kinetics in Vivo. In: ACS Chemical Neuroscience. 2014 ; Vol. 6, No. 9. pp. 1509-1516.
@article{61a8837f55784343a8b91b7958073bc5,
title = "Improved Calibration of Voltammetric Sensors for Studying Pharmacological Effects on Dopamine Transporter Kinetics in Vivo",
abstract = "The distribution and density of neurons within the brain poses many challenges when making quantitative measurements of neurotransmission in the extracellular space. A volume neurotransmitter is released into the synapse during chemical communication and must diffuse through the extracellular space to an implanted sensor for real-time in situ detection. Fast-scan cyclic voltammetry is an excellent technique for measuring biologically relevant concentration changes in vivo; however, the sensitivity is limited by mass-transport-limited adsorption. Due to the resistance to mass transfer in the brain, the response time of voltammetric sensors is increased, which decreases the sensitivity and the temporal fidelity of the measurement. Here, experimental results reveal how the tortuosity of the extracellular space affects the response of the electrode. Additionally, a model of mass-transport-limited adsorption is utilized to account for both the strength of adsorption and the magnitude of the diffusion coefficient to calculate the response time of the electrode. The response time is then used to determine the concentration of dopamine released in response to salient stimuli. We present the method of kinetic calibration of in vivo voltammetric data and apply the method to discern changes in the KM for the murine dopamine transporter. The KM increased from 0.32 ± 0.08 μM (n = 3 animals) prior to drug administration to 2.72 ± 0.37 μM (n = 3 animals) after treatment with GBR-12909.",
keywords = "calibration, Dopamine, electrochemistry, hindered diffusion, in vivo, kinetics",
author = "Atcherley, {Christopher W.} and Laude, {Nicholas D.} and Monroe, {Eric B.} and Wood, {Kevin M.} and Parastoo Hashemi and Heien, {Michael L}",
year = "2014",
month = "7",
day = "25",
doi = "10.1021/cn500020s",
language = "English (US)",
volume = "6",
pages = "1509--1516",
journal = "ACS Chemical Neuroscience",
issn = "1948-7193",
publisher = "American Chemical Society",
number = "9",

}

TY - JOUR

T1 - Improved Calibration of Voltammetric Sensors for Studying Pharmacological Effects on Dopamine Transporter Kinetics in Vivo

AU - Atcherley, Christopher W.

AU - Laude, Nicholas D.

AU - Monroe, Eric B.

AU - Wood, Kevin M.

AU - Hashemi, Parastoo

AU - Heien, Michael L

PY - 2014/7/25

Y1 - 2014/7/25

N2 - The distribution and density of neurons within the brain poses many challenges when making quantitative measurements of neurotransmission in the extracellular space. A volume neurotransmitter is released into the synapse during chemical communication and must diffuse through the extracellular space to an implanted sensor for real-time in situ detection. Fast-scan cyclic voltammetry is an excellent technique for measuring biologically relevant concentration changes in vivo; however, the sensitivity is limited by mass-transport-limited adsorption. Due to the resistance to mass transfer in the brain, the response time of voltammetric sensors is increased, which decreases the sensitivity and the temporal fidelity of the measurement. Here, experimental results reveal how the tortuosity of the extracellular space affects the response of the electrode. Additionally, a model of mass-transport-limited adsorption is utilized to account for both the strength of adsorption and the magnitude of the diffusion coefficient to calculate the response time of the electrode. The response time is then used to determine the concentration of dopamine released in response to salient stimuli. We present the method of kinetic calibration of in vivo voltammetric data and apply the method to discern changes in the KM for the murine dopamine transporter. The KM increased from 0.32 ± 0.08 μM (n = 3 animals) prior to drug administration to 2.72 ± 0.37 μM (n = 3 animals) after treatment with GBR-12909.

AB - The distribution and density of neurons within the brain poses many challenges when making quantitative measurements of neurotransmission in the extracellular space. A volume neurotransmitter is released into the synapse during chemical communication and must diffuse through the extracellular space to an implanted sensor for real-time in situ detection. Fast-scan cyclic voltammetry is an excellent technique for measuring biologically relevant concentration changes in vivo; however, the sensitivity is limited by mass-transport-limited adsorption. Due to the resistance to mass transfer in the brain, the response time of voltammetric sensors is increased, which decreases the sensitivity and the temporal fidelity of the measurement. Here, experimental results reveal how the tortuosity of the extracellular space affects the response of the electrode. Additionally, a model of mass-transport-limited adsorption is utilized to account for both the strength of adsorption and the magnitude of the diffusion coefficient to calculate the response time of the electrode. The response time is then used to determine the concentration of dopamine released in response to salient stimuli. We present the method of kinetic calibration of in vivo voltammetric data and apply the method to discern changes in the KM for the murine dopamine transporter. The KM increased from 0.32 ± 0.08 μM (n = 3 animals) prior to drug administration to 2.72 ± 0.37 μM (n = 3 animals) after treatment with GBR-12909.

KW - calibration

KW - Dopamine

KW - electrochemistry

KW - hindered diffusion

KW - in vivo

KW - kinetics

UR - http://www.scopus.com/inward/record.url?scp=84939837768&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84939837768&partnerID=8YFLogxK

U2 - 10.1021/cn500020s

DO - 10.1021/cn500020s

M3 - Article

VL - 6

SP - 1509

EP - 1516

JO - ACS Chemical Neuroscience

JF - ACS Chemical Neuroscience

SN - 1948-7193

IS - 9

ER -