Abstract

Sources and concentrations of indoor air pollutants and aeroallergens were evaluated in the arid Southwest community of Tucson, Arizona. One major purpose was to appraise the interaction of indoor and outdoor human exposures. A rough time budget study showed that 74% of adults spent 75% or more of their time in some indoor environment. Outdoor and indoor concentrations of TSP, RSP, CO, O3 and aeroallergens were measured for 41 detached dwellings. Small area and basin monitoring occurred for TSP, CO, NO2, O3 and aeroallergens; ambient TSP frequently exceeds NAAQS and both CO and O3 do occasionally. Indoor TSP and RSP were lower than outdoors and were of a different composition. Outdoor infiltration falls rapidly for particles and pollen, related to distance indoors. CO was low and O3 was very low indoors. TSP and RSP correlated significantly with tobacco smoking and CO correlated with gas stove usage. Temperature varied minimally indoors and relative humidity indoors was similar to outdoor readings in this climate. It was concluded that better particle characterization and better estimates of total exposure are required.

Original languageEnglish (US)
Pages (from-to)1035-1038
Number of pages4
JournalJournal of the Air Pollution Control Association
Volume34
Issue number10
StatePublished - Oct 1984

Fingerprint

Gas stoves
Allergens
Indoor Air Pollution
Tobacco
Carbon Monoxide
Air pollution
Infiltration
Atmospheric humidity
atmospheric pollution
Monitoring
monitoring
indoor air
Air
smoking
Chemical analysis
tobacco
relative humidity
infiltration
pollen
Temperature

ASJC Scopus subject areas

  • Engineering(all)
  • Medicine(all)
  • Earth and Planetary Sciences(all)
  • Environmental Science(all)

Cite this

Indoor-outdoor air pollution, allergen and meteorological monitoring in an arid southwest area. / Lebowitz, M. D.; Corman, G.; O'Rourke, Mary Kay; Holberg, C. J.

In: Journal of the Air Pollution Control Association, Vol. 34, No. 10, 10.1984, p. 1035-1038.

Research output: Contribution to journalArticle

@article{72f641fecda743d7a59988b95afa8136,
title = "Indoor-outdoor air pollution, allergen and meteorological monitoring in an arid southwest area",
abstract = "Sources and concentrations of indoor air pollutants and aeroallergens were evaluated in the arid Southwest community of Tucson, Arizona. One major purpose was to appraise the interaction of indoor and outdoor human exposures. A rough time budget study showed that 74{\%} of adults spent 75{\%} or more of their time in some indoor environment. Outdoor and indoor concentrations of TSP, RSP, CO, O3 and aeroallergens were measured for 41 detached dwellings. Small area and basin monitoring occurred for TSP, CO, NO2, O3 and aeroallergens; ambient TSP frequently exceeds NAAQS and both CO and O3 do occasionally. Indoor TSP and RSP were lower than outdoors and were of a different composition. Outdoor infiltration falls rapidly for particles and pollen, related to distance indoors. CO was low and O3 was very low indoors. TSP and RSP correlated significantly with tobacco smoking and CO correlated with gas stove usage. Temperature varied minimally indoors and relative humidity indoors was similar to outdoor readings in this climate. It was concluded that better particle characterization and better estimates of total exposure are required.",
author = "Lebowitz, {M. D.} and G. Corman and O'Rourke, {Mary Kay} and Holberg, {C. J.}",
year = "1984",
month = "10",
language = "English (US)",
volume = "34",
pages = "1035--1038",
journal = "Journal of the Air and Waste Management Association",
issn = "1096-2247",
publisher = "Air and Waste Management Association",
number = "10",

}

TY - JOUR

T1 - Indoor-outdoor air pollution, allergen and meteorological monitoring in an arid southwest area

AU - Lebowitz, M. D.

AU - Corman, G.

AU - O'Rourke, Mary Kay

AU - Holberg, C. J.

PY - 1984/10

Y1 - 1984/10

N2 - Sources and concentrations of indoor air pollutants and aeroallergens were evaluated in the arid Southwest community of Tucson, Arizona. One major purpose was to appraise the interaction of indoor and outdoor human exposures. A rough time budget study showed that 74% of adults spent 75% or more of their time in some indoor environment. Outdoor and indoor concentrations of TSP, RSP, CO, O3 and aeroallergens were measured for 41 detached dwellings. Small area and basin monitoring occurred for TSP, CO, NO2, O3 and aeroallergens; ambient TSP frequently exceeds NAAQS and both CO and O3 do occasionally. Indoor TSP and RSP were lower than outdoors and were of a different composition. Outdoor infiltration falls rapidly for particles and pollen, related to distance indoors. CO was low and O3 was very low indoors. TSP and RSP correlated significantly with tobacco smoking and CO correlated with gas stove usage. Temperature varied minimally indoors and relative humidity indoors was similar to outdoor readings in this climate. It was concluded that better particle characterization and better estimates of total exposure are required.

AB - Sources and concentrations of indoor air pollutants and aeroallergens were evaluated in the arid Southwest community of Tucson, Arizona. One major purpose was to appraise the interaction of indoor and outdoor human exposures. A rough time budget study showed that 74% of adults spent 75% or more of their time in some indoor environment. Outdoor and indoor concentrations of TSP, RSP, CO, O3 and aeroallergens were measured for 41 detached dwellings. Small area and basin monitoring occurred for TSP, CO, NO2, O3 and aeroallergens; ambient TSP frequently exceeds NAAQS and both CO and O3 do occasionally. Indoor TSP and RSP were lower than outdoors and were of a different composition. Outdoor infiltration falls rapidly for particles and pollen, related to distance indoors. CO was low and O3 was very low indoors. TSP and RSP correlated significantly with tobacco smoking and CO correlated with gas stove usage. Temperature varied minimally indoors and relative humidity indoors was similar to outdoor readings in this climate. It was concluded that better particle characterization and better estimates of total exposure are required.

UR - http://www.scopus.com/inward/record.url?scp=0021507608&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021507608&partnerID=8YFLogxK

M3 - Article

C2 - 6491056

AN - SCOPUS:0021507608

VL - 34

SP - 1035

EP - 1038

JO - Journal of the Air and Waste Management Association

JF - Journal of the Air and Waste Management Association

SN - 1096-2247

IS - 10