Influence of residence time of reclaimed water within distribution systems on water quality

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

The influence of residence time of reclaimed water within water distribution systems on microbial water quality was evaluated in two wastewater reclamation facilities in southern Arizona over a 15-month period. These utilities differed in age, geographic location, means of treatment, and disinfection (i.e. UV versus chlorine). At both facilities, samples were collected from the point of compliance (POC) directly after disinfection, and at discrete locations with increasing distance from the POC. Following entry into reclaimed water distribution systems, overall microbial water quality decreased rapidly due to microbial regrowth. However, following such regrowth, microbial concentrations remained relatively constant. Water-based opportunistic pathogens (Legionella, Mycobacterium, and Aeromonas) were frequently detected in both reclaimed water systems. In contrast, waterborne indicators such as Escherichia coli and Enterococcus were rarely detected, and only at low concentrations. These dates suggest the need for new indicators of water-based pathogens to be developed. Rechlorination in one of the distribution systems only reduced the concentration of bacteria temporarily due to rapid dissipation of chlorine, and subsequent regrowth of both water-based pathogens and indicators. Amoebic activity was detected in approximately one-third of all samples tested from both utilities, but was not correlated with either water-based pathogens or indicators.

Original languageEnglish (US)
Pages (from-to)185-196
Number of pages12
JournalJournal of Water Reuse and Desalination
Volume3
Issue number3
DOIs
StatePublished - 2013

Fingerprint

Water distribution systems
Water quality
residence time
Pathogens
water quality
Water
regrowth
pathogen
Disinfection
Chlorine
disinfection
water
compliance
chlorine
Wastewater reclamation
distribution system
Escherichia coli
water distribution system
dissipation
Bacteria

Keywords

  • Reclaimed water quality
  • Residence time

ASJC Scopus subject areas

  • Filtration and Separation
  • Water Science and Technology

Cite this

@article{aa4d7e5be41a494f9f8fc813cd823a4d,
title = "Influence of residence time of reclaimed water within distribution systems on water quality",
abstract = "The influence of residence time of reclaimed water within water distribution systems on microbial water quality was evaluated in two wastewater reclamation facilities in southern Arizona over a 15-month period. These utilities differed in age, geographic location, means of treatment, and disinfection (i.e. UV versus chlorine). At both facilities, samples were collected from the point of compliance (POC) directly after disinfection, and at discrete locations with increasing distance from the POC. Following entry into reclaimed water distribution systems, overall microbial water quality decreased rapidly due to microbial regrowth. However, following such regrowth, microbial concentrations remained relatively constant. Water-based opportunistic pathogens (Legionella, Mycobacterium, and Aeromonas) were frequently detected in both reclaimed water systems. In contrast, waterborne indicators such as Escherichia coli and Enterococcus were rarely detected, and only at low concentrations. These dates suggest the need for new indicators of water-based pathogens to be developed. Rechlorination in one of the distribution systems only reduced the concentration of bacteria temporarily due to rapid dissipation of chlorine, and subsequent regrowth of both water-based pathogens and indicators. Amoebic activity was detected in approximately one-third of all samples tested from both utilities, but was not correlated with either water-based pathogens or indicators.",
keywords = "Reclaimed water quality, Residence time",
author = "Ajibode, {Oluyomi M.} and Rock, {Channah M} and Bright, {Kelly R} and Mclain, {Jean E T} and Gerba, {Charles P} and Pepper, {Ian L}",
year = "2013",
doi = "10.2166/wrd.2013.088",
language = "English (US)",
volume = "3",
pages = "185--196",
journal = "Journal of Water Reuse and Desalination",
issn = "2220-1319",
publisher = "IWA Publishing",
number = "3",

}

TY - JOUR

T1 - Influence of residence time of reclaimed water within distribution systems on water quality

AU - Ajibode, Oluyomi M.

AU - Rock, Channah M

AU - Bright, Kelly R

AU - Mclain, Jean E T

AU - Gerba, Charles P

AU - Pepper, Ian L

PY - 2013

Y1 - 2013

N2 - The influence of residence time of reclaimed water within water distribution systems on microbial water quality was evaluated in two wastewater reclamation facilities in southern Arizona over a 15-month period. These utilities differed in age, geographic location, means of treatment, and disinfection (i.e. UV versus chlorine). At both facilities, samples were collected from the point of compliance (POC) directly after disinfection, and at discrete locations with increasing distance from the POC. Following entry into reclaimed water distribution systems, overall microbial water quality decreased rapidly due to microbial regrowth. However, following such regrowth, microbial concentrations remained relatively constant. Water-based opportunistic pathogens (Legionella, Mycobacterium, and Aeromonas) were frequently detected in both reclaimed water systems. In contrast, waterborne indicators such as Escherichia coli and Enterococcus were rarely detected, and only at low concentrations. These dates suggest the need for new indicators of water-based pathogens to be developed. Rechlorination in one of the distribution systems only reduced the concentration of bacteria temporarily due to rapid dissipation of chlorine, and subsequent regrowth of both water-based pathogens and indicators. Amoebic activity was detected in approximately one-third of all samples tested from both utilities, but was not correlated with either water-based pathogens or indicators.

AB - The influence of residence time of reclaimed water within water distribution systems on microbial water quality was evaluated in two wastewater reclamation facilities in southern Arizona over a 15-month period. These utilities differed in age, geographic location, means of treatment, and disinfection (i.e. UV versus chlorine). At both facilities, samples were collected from the point of compliance (POC) directly after disinfection, and at discrete locations with increasing distance from the POC. Following entry into reclaimed water distribution systems, overall microbial water quality decreased rapidly due to microbial regrowth. However, following such regrowth, microbial concentrations remained relatively constant. Water-based opportunistic pathogens (Legionella, Mycobacterium, and Aeromonas) were frequently detected in both reclaimed water systems. In contrast, waterborne indicators such as Escherichia coli and Enterococcus were rarely detected, and only at low concentrations. These dates suggest the need for new indicators of water-based pathogens to be developed. Rechlorination in one of the distribution systems only reduced the concentration of bacteria temporarily due to rapid dissipation of chlorine, and subsequent regrowth of both water-based pathogens and indicators. Amoebic activity was detected in approximately one-third of all samples tested from both utilities, but was not correlated with either water-based pathogens or indicators.

KW - Reclaimed water quality

KW - Residence time

UR - http://www.scopus.com/inward/record.url?scp=84894288853&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84894288853&partnerID=8YFLogxK

U2 - 10.2166/wrd.2013.088

DO - 10.2166/wrd.2013.088

M3 - Article

AN - SCOPUS:84894288853

VL - 3

SP - 185

EP - 196

JO - Journal of Water Reuse and Desalination

JF - Journal of Water Reuse and Desalination

SN - 2220-1319

IS - 3

ER -