Investigation of a grating-based stretcher/compressor for carrier-envelope phase stabilized fs pulses

Isabell Thomann, Etienne Gagnon, Ronald J Jones, Arvinder Singh Sandhu, Amy Lytle, Ryan Anderson, Jun Ye, Margaret Murnane, Henry Kapteyn

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

The effect of grating based pulse stretcher/compressor (SC) on the carrier-envelope phase stability of femtosecond pulses was investigated. Controlled beam positioning fluctuations was introduced to distinguish between intrinsic SC effects and amplitude-to-phase conversion. The measurements allowed to place an upper limit on the sensitivity of the SC system. The results demonstrate that there is no strong coupling mechanism between CEP and beam pointing through a SC.

Original languageEnglish (US)
Pages (from-to)3493-3499
Number of pages7
JournalOptics Express
Volume12
Issue number15
DOIs
StatePublished - 2004
Externally publishedYes

Fingerprint

compressors
envelopes
gratings
pulses
positioning
sensitivity

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Investigation of a grating-based stretcher/compressor for carrier-envelope phase stabilized fs pulses. / Thomann, Isabell; Gagnon, Etienne; Jones, Ronald J; Sandhu, Arvinder Singh; Lytle, Amy; Anderson, Ryan; Ye, Jun; Murnane, Margaret; Kapteyn, Henry.

In: Optics Express, Vol. 12, No. 15, 2004, p. 3493-3499.

Research output: Contribution to journalArticle

Thomann, I, Gagnon, E, Jones, RJ, Sandhu, AS, Lytle, A, Anderson, R, Ye, J, Murnane, M & Kapteyn, H 2004, 'Investigation of a grating-based stretcher/compressor for carrier-envelope phase stabilized fs pulses', Optics Express, vol. 12, no. 15, pp. 3493-3499. https://doi.org/10.1364/OPEX.12.003493
Thomann, Isabell ; Gagnon, Etienne ; Jones, Ronald J ; Sandhu, Arvinder Singh ; Lytle, Amy ; Anderson, Ryan ; Ye, Jun ; Murnane, Margaret ; Kapteyn, Henry. / Investigation of a grating-based stretcher/compressor for carrier-envelope phase stabilized fs pulses. In: Optics Express. 2004 ; Vol. 12, No. 15. pp. 3493-3499.
@article{7d0b80bdbd1c4718a54e2052f9b78add,
title = "Investigation of a grating-based stretcher/compressor for carrier-envelope phase stabilized fs pulses",
abstract = "The effect of grating based pulse stretcher/compressor (SC) on the carrier-envelope phase stability of femtosecond pulses was investigated. Controlled beam positioning fluctuations was introduced to distinguish between intrinsic SC effects and amplitude-to-phase conversion. The measurements allowed to place an upper limit on the sensitivity of the SC system. The results demonstrate that there is no strong coupling mechanism between CEP and beam pointing through a SC.",
author = "Isabell Thomann and Etienne Gagnon and Jones, {Ronald J} and Sandhu, {Arvinder Singh} and Amy Lytle and Ryan Anderson and Jun Ye and Margaret Murnane and Henry Kapteyn",
year = "2004",
doi = "10.1364/OPEX.12.003493",
language = "English (US)",
volume = "12",
pages = "3493--3499",
journal = "Optics Express",
issn = "1094-4087",
publisher = "The Optical Society",
number = "15",

}

TY - JOUR

T1 - Investigation of a grating-based stretcher/compressor for carrier-envelope phase stabilized fs pulses

AU - Thomann, Isabell

AU - Gagnon, Etienne

AU - Jones, Ronald J

AU - Sandhu, Arvinder Singh

AU - Lytle, Amy

AU - Anderson, Ryan

AU - Ye, Jun

AU - Murnane, Margaret

AU - Kapteyn, Henry

PY - 2004

Y1 - 2004

N2 - The effect of grating based pulse stretcher/compressor (SC) on the carrier-envelope phase stability of femtosecond pulses was investigated. Controlled beam positioning fluctuations was introduced to distinguish between intrinsic SC effects and amplitude-to-phase conversion. The measurements allowed to place an upper limit on the sensitivity of the SC system. The results demonstrate that there is no strong coupling mechanism between CEP and beam pointing through a SC.

AB - The effect of grating based pulse stretcher/compressor (SC) on the carrier-envelope phase stability of femtosecond pulses was investigated. Controlled beam positioning fluctuations was introduced to distinguish between intrinsic SC effects and amplitude-to-phase conversion. The measurements allowed to place an upper limit on the sensitivity of the SC system. The results demonstrate that there is no strong coupling mechanism between CEP and beam pointing through a SC.

UR - http://www.scopus.com/inward/record.url?scp=4644276637&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4644276637&partnerID=8YFLogxK

U2 - 10.1364/OPEX.12.003493

DO - 10.1364/OPEX.12.003493

M3 - Article

VL - 12

SP - 3493

EP - 3499

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 15

ER -