Investigation of optimal kVp settings for CT mammography using a flat-panel imager

Stephen J. Glick, Srinivasan Vedantham, Andrew Karellas

Research output: Contribution to journalConference article

56 Citations (Scopus)

Abstract

Detection of lesions in planar mammograms is a difficult task, predominantly due to the masking effect of superimposed parenchymal breast patterns. Tomographic imaging of the breast can provide image slices through the breast, possibly reducing this masking effect. In recent years, there has been interest in developing CT mammography using flat-panel digital detectors in a truncated cone-beam geometry. In this study, we have developed a framework for determining optimal design and acquisition parameters for such a CT mammographic system. The ideal observer SNR is used as a figure-of-merit, under the assumptions that the imaging system is linear and shift-invariant, and that the noise is stationary. The ideal observer calculation uses mathematical models of signal and noise propagation through the flat-panel detector, and realistic models of the lesion detection task in breast imaging. It is used to investigate optimal kVp settings of a tungsten anode spectra for CT imaging of the uncompressed breast, given the constraint of an average glandular dose approximately equivalent to that of a two-view planar mammography study. It is observed that modeling a realistic mammographic background structure into the detection task can affect the optimal kVp settings suggested by the ideal observer SNR. Since the exposure/view in flat-panel CT mammography is considerably lower than for planar mammography, it is observed that electronic additive noise can also affect the optimal kVp setting. In general, the optimal kVp settings for the tungsten anode spectra studied here were in the range of 30-50 kVp.

Original languageEnglish (US)
Pages (from-to)392-402
Number of pages11
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume4682
DOIs
StatePublished - Jan 1 2002
Externally publishedYes
EventMedical Imaging 2002: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 24 2002Feb 26 2002

Fingerprint

Mammography
Imager
Image sensors
breast
Observer
Tungsten
Imaging
Masking
Imaging techniques
masking
Anodes
lesions
Detector
Truncated cone or frustum
Detectors
tungsten
anodes
Mammogram
Additive noise
noise propagation

Keywords

  • CT mammography
  • Ideal observer SNR
  • Linear-systems theory
  • Optimization

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

Cite this

Investigation of optimal kVp settings for CT mammography using a flat-panel imager. / Glick, Stephen J.; Vedantham, Srinivasan; Karellas, Andrew.

In: Proceedings of SPIE - The International Society for Optical Engineering, Vol. 4682, 01.01.2002, p. 392-402.

Research output: Contribution to journalConference article

@article{302ffd43cd3f45d7b2b3baa309265e11,
title = "Investigation of optimal kVp settings for CT mammography using a flat-panel imager",
abstract = "Detection of lesions in planar mammograms is a difficult task, predominantly due to the masking effect of superimposed parenchymal breast patterns. Tomographic imaging of the breast can provide image slices through the breast, possibly reducing this masking effect. In recent years, there has been interest in developing CT mammography using flat-panel digital detectors in a truncated cone-beam geometry. In this study, we have developed a framework for determining optimal design and acquisition parameters for such a CT mammographic system. The ideal observer SNR is used as a figure-of-merit, under the assumptions that the imaging system is linear and shift-invariant, and that the noise is stationary. The ideal observer calculation uses mathematical models of signal and noise propagation through the flat-panel detector, and realistic models of the lesion detection task in breast imaging. It is used to investigate optimal kVp settings of a tungsten anode spectra for CT imaging of the uncompressed breast, given the constraint of an average glandular dose approximately equivalent to that of a two-view planar mammography study. It is observed that modeling a realistic mammographic background structure into the detection task can affect the optimal kVp settings suggested by the ideal observer SNR. Since the exposure/view in flat-panel CT mammography is considerably lower than for planar mammography, it is observed that electronic additive noise can also affect the optimal kVp setting. In general, the optimal kVp settings for the tungsten anode spectra studied here were in the range of 30-50 kVp.",
keywords = "CT mammography, Ideal observer SNR, Linear-systems theory, Optimization",
author = "Glick, {Stephen J.} and Srinivasan Vedantham and Andrew Karellas",
year = "2002",
month = "1",
day = "1",
doi = "10.1117/12.465581",
language = "English (US)",
volume = "4682",
pages = "392--402",
journal = "Proceedings of SPIE - The International Society for Optical Engineering",
issn = "0277-786X",
publisher = "SPIE",

}

TY - JOUR

T1 - Investigation of optimal kVp settings for CT mammography using a flat-panel imager

AU - Glick, Stephen J.

AU - Vedantham, Srinivasan

AU - Karellas, Andrew

PY - 2002/1/1

Y1 - 2002/1/1

N2 - Detection of lesions in planar mammograms is a difficult task, predominantly due to the masking effect of superimposed parenchymal breast patterns. Tomographic imaging of the breast can provide image slices through the breast, possibly reducing this masking effect. In recent years, there has been interest in developing CT mammography using flat-panel digital detectors in a truncated cone-beam geometry. In this study, we have developed a framework for determining optimal design and acquisition parameters for such a CT mammographic system. The ideal observer SNR is used as a figure-of-merit, under the assumptions that the imaging system is linear and shift-invariant, and that the noise is stationary. The ideal observer calculation uses mathematical models of signal and noise propagation through the flat-panel detector, and realistic models of the lesion detection task in breast imaging. It is used to investigate optimal kVp settings of a tungsten anode spectra for CT imaging of the uncompressed breast, given the constraint of an average glandular dose approximately equivalent to that of a two-view planar mammography study. It is observed that modeling a realistic mammographic background structure into the detection task can affect the optimal kVp settings suggested by the ideal observer SNR. Since the exposure/view in flat-panel CT mammography is considerably lower than for planar mammography, it is observed that electronic additive noise can also affect the optimal kVp setting. In general, the optimal kVp settings for the tungsten anode spectra studied here were in the range of 30-50 kVp.

AB - Detection of lesions in planar mammograms is a difficult task, predominantly due to the masking effect of superimposed parenchymal breast patterns. Tomographic imaging of the breast can provide image slices through the breast, possibly reducing this masking effect. In recent years, there has been interest in developing CT mammography using flat-panel digital detectors in a truncated cone-beam geometry. In this study, we have developed a framework for determining optimal design and acquisition parameters for such a CT mammographic system. The ideal observer SNR is used as a figure-of-merit, under the assumptions that the imaging system is linear and shift-invariant, and that the noise is stationary. The ideal observer calculation uses mathematical models of signal and noise propagation through the flat-panel detector, and realistic models of the lesion detection task in breast imaging. It is used to investigate optimal kVp settings of a tungsten anode spectra for CT imaging of the uncompressed breast, given the constraint of an average glandular dose approximately equivalent to that of a two-view planar mammography study. It is observed that modeling a realistic mammographic background structure into the detection task can affect the optimal kVp settings suggested by the ideal observer SNR. Since the exposure/view in flat-panel CT mammography is considerably lower than for planar mammography, it is observed that electronic additive noise can also affect the optimal kVp setting. In general, the optimal kVp settings for the tungsten anode spectra studied here were in the range of 30-50 kVp.

KW - CT mammography

KW - Ideal observer SNR

KW - Linear-systems theory

KW - Optimization

UR - http://www.scopus.com/inward/record.url?scp=0036033581&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036033581&partnerID=8YFLogxK

U2 - 10.1117/12.465581

DO - 10.1117/12.465581

M3 - Conference article

AN - SCOPUS:0036033581

VL - 4682

SP - 392

EP - 402

JO - Proceedings of SPIE - The International Society for Optical Engineering

JF - Proceedings of SPIE - The International Society for Optical Engineering

SN - 0277-786X

ER -