Measurement of the EMG-force relationship in a human upper airway muscle

D. Fuller, J. Sullivan, E. Essif, K. Personius, Ralph F Fregosi

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The upper airway muscles play an important role in breathing, swallowing, and speaking, but little is known about the electromyogram (EMG)-force relationship of these muscles. We have measured the peak integrated EMG activity (iEMG) and force of human nasal dilator muscles (NDM) with a custom- designed headpiece that was attached via the forehead and upper lip. The headpiece contains a micromanipulator that holds a rod with a load cell mounted on its tip. The reproducibility of the force measurements was examined by measuring the lateral or 'flaring' force of the NDM in multiple trials on two separate occasions in 13 subjects. For these studies the subjects were instructed to perform maximal voluntary contractions (MVCs). Test-retest reproducibility averaged 8.3% (coefficient of variation) for within-day comparisons and 13.7% between days. We also measured iEMG and NDM force during an incremental exercise test in nine of the subjects; they were instructed to breathe nasally throughout one 30-s epoch at rest and at each workload. The iEMG and force during peak exercise (175-275 W) averaged 81 ± 26% (SD) MVC and 235 ± 127 mN (~75% MVC), respectively. The iEMG during incremental exercise was linearly related to the peak force (r = 0.90, P < 0.001). Contractile properties were measured in seven of the subjects by application of single supramaximal shocks (0.1-ms pulse) to the facial nerve. Twitch force averaged 9 ± 6% MVC, and the time to peak force was 62 ± 13 ms, which is considerably faster than that in human diaphragm or elbow flexors. The following conclusions were made: 1) our method is useful for making reproducible measurements of NDM force during voluntary, involuntary, and electrically evoked contractions; 2) the force measured with this system closely parallels the neural drive (iEMG) to the NDM; 3) the force output of the NDM during peak exercise with nasal breathing (i.e., 75% MVC) is substantial; and 4) human NDM have relatively rapid contractile properties.

Original languageEnglish (US)
Pages (from-to)270-278
Number of pages9
JournalJournal of Applied Physiology
Volume79
Issue number1
StatePublished - 1995

Fingerprint

Electromyography
Nose
Muscles
Respiration
Forehead
Facial Nerve
Deglutition
Elbow
Lip
Diaphragm
Workload
Exercise Test
Human Activities
Shock

Keywords

  • control of breathing
  • electromyography
  • evoked potentials
  • facial nerve
  • maximal voluntary contractions
  • muscle contractile properties
  • muscle force
  • nasal dilator muscles

ASJC Scopus subject areas

  • Endocrinology
  • Physiology
  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

Measurement of the EMG-force relationship in a human upper airway muscle. / Fuller, D.; Sullivan, J.; Essif, E.; Personius, K.; Fregosi, Ralph F.

In: Journal of Applied Physiology, Vol. 79, No. 1, 1995, p. 270-278.

Research output: Contribution to journalArticle

Fuller, D, Sullivan, J, Essif, E, Personius, K & Fregosi, RF 1995, 'Measurement of the EMG-force relationship in a human upper airway muscle', Journal of Applied Physiology, vol. 79, no. 1, pp. 270-278.
Fuller, D. ; Sullivan, J. ; Essif, E. ; Personius, K. ; Fregosi, Ralph F. / Measurement of the EMG-force relationship in a human upper airway muscle. In: Journal of Applied Physiology. 1995 ; Vol. 79, No. 1. pp. 270-278.
@article{a905f090b9724f44ab9aa88d18252b65,
title = "Measurement of the EMG-force relationship in a human upper airway muscle",
abstract = "The upper airway muscles play an important role in breathing, swallowing, and speaking, but little is known about the electromyogram (EMG)-force relationship of these muscles. We have measured the peak integrated EMG activity (iEMG) and force of human nasal dilator muscles (NDM) with a custom- designed headpiece that was attached via the forehead and upper lip. The headpiece contains a micromanipulator that holds a rod with a load cell mounted on its tip. The reproducibility of the force measurements was examined by measuring the lateral or 'flaring' force of the NDM in multiple trials on two separate occasions in 13 subjects. For these studies the subjects were instructed to perform maximal voluntary contractions (MVCs). Test-retest reproducibility averaged 8.3{\%} (coefficient of variation) for within-day comparisons and 13.7{\%} between days. We also measured iEMG and NDM force during an incremental exercise test in nine of the subjects; they were instructed to breathe nasally throughout one 30-s epoch at rest and at each workload. The iEMG and force during peak exercise (175-275 W) averaged 81 ± 26{\%} (SD) MVC and 235 ± 127 mN (~75{\%} MVC), respectively. The iEMG during incremental exercise was linearly related to the peak force (r = 0.90, P < 0.001). Contractile properties were measured in seven of the subjects by application of single supramaximal shocks (0.1-ms pulse) to the facial nerve. Twitch force averaged 9 ± 6{\%} MVC, and the time to peak force was 62 ± 13 ms, which is considerably faster than that in human diaphragm or elbow flexors. The following conclusions were made: 1) our method is useful for making reproducible measurements of NDM force during voluntary, involuntary, and electrically evoked contractions; 2) the force measured with this system closely parallels the neural drive (iEMG) to the NDM; 3) the force output of the NDM during peak exercise with nasal breathing (i.e., 75{\%} MVC) is substantial; and 4) human NDM have relatively rapid contractile properties.",
keywords = "control of breathing, electromyography, evoked potentials, facial nerve, maximal voluntary contractions, muscle contractile properties, muscle force, nasal dilator muscles",
author = "D. Fuller and J. Sullivan and E. Essif and K. Personius and Fregosi, {Ralph F}",
year = "1995",
language = "English (US)",
volume = "79",
pages = "270--278",
journal = "Journal of Applied Physiology",
issn = "8750-7587",
publisher = "American Physiological Society",
number = "1",

}

TY - JOUR

T1 - Measurement of the EMG-force relationship in a human upper airway muscle

AU - Fuller, D.

AU - Sullivan, J.

AU - Essif, E.

AU - Personius, K.

AU - Fregosi, Ralph F

PY - 1995

Y1 - 1995

N2 - The upper airway muscles play an important role in breathing, swallowing, and speaking, but little is known about the electromyogram (EMG)-force relationship of these muscles. We have measured the peak integrated EMG activity (iEMG) and force of human nasal dilator muscles (NDM) with a custom- designed headpiece that was attached via the forehead and upper lip. The headpiece contains a micromanipulator that holds a rod with a load cell mounted on its tip. The reproducibility of the force measurements was examined by measuring the lateral or 'flaring' force of the NDM in multiple trials on two separate occasions in 13 subjects. For these studies the subjects were instructed to perform maximal voluntary contractions (MVCs). Test-retest reproducibility averaged 8.3% (coefficient of variation) for within-day comparisons and 13.7% between days. We also measured iEMG and NDM force during an incremental exercise test in nine of the subjects; they were instructed to breathe nasally throughout one 30-s epoch at rest and at each workload. The iEMG and force during peak exercise (175-275 W) averaged 81 ± 26% (SD) MVC and 235 ± 127 mN (~75% MVC), respectively. The iEMG during incremental exercise was linearly related to the peak force (r = 0.90, P < 0.001). Contractile properties were measured in seven of the subjects by application of single supramaximal shocks (0.1-ms pulse) to the facial nerve. Twitch force averaged 9 ± 6% MVC, and the time to peak force was 62 ± 13 ms, which is considerably faster than that in human diaphragm or elbow flexors. The following conclusions were made: 1) our method is useful for making reproducible measurements of NDM force during voluntary, involuntary, and electrically evoked contractions; 2) the force measured with this system closely parallels the neural drive (iEMG) to the NDM; 3) the force output of the NDM during peak exercise with nasal breathing (i.e., 75% MVC) is substantial; and 4) human NDM have relatively rapid contractile properties.

AB - The upper airway muscles play an important role in breathing, swallowing, and speaking, but little is known about the electromyogram (EMG)-force relationship of these muscles. We have measured the peak integrated EMG activity (iEMG) and force of human nasal dilator muscles (NDM) with a custom- designed headpiece that was attached via the forehead and upper lip. The headpiece contains a micromanipulator that holds a rod with a load cell mounted on its tip. The reproducibility of the force measurements was examined by measuring the lateral or 'flaring' force of the NDM in multiple trials on two separate occasions in 13 subjects. For these studies the subjects were instructed to perform maximal voluntary contractions (MVCs). Test-retest reproducibility averaged 8.3% (coefficient of variation) for within-day comparisons and 13.7% between days. We also measured iEMG and NDM force during an incremental exercise test in nine of the subjects; they were instructed to breathe nasally throughout one 30-s epoch at rest and at each workload. The iEMG and force during peak exercise (175-275 W) averaged 81 ± 26% (SD) MVC and 235 ± 127 mN (~75% MVC), respectively. The iEMG during incremental exercise was linearly related to the peak force (r = 0.90, P < 0.001). Contractile properties were measured in seven of the subjects by application of single supramaximal shocks (0.1-ms pulse) to the facial nerve. Twitch force averaged 9 ± 6% MVC, and the time to peak force was 62 ± 13 ms, which is considerably faster than that in human diaphragm or elbow flexors. The following conclusions were made: 1) our method is useful for making reproducible measurements of NDM force during voluntary, involuntary, and electrically evoked contractions; 2) the force measured with this system closely parallels the neural drive (iEMG) to the NDM; 3) the force output of the NDM during peak exercise with nasal breathing (i.e., 75% MVC) is substantial; and 4) human NDM have relatively rapid contractile properties.

KW - control of breathing

KW - electromyography

KW - evoked potentials

KW - facial nerve

KW - maximal voluntary contractions

KW - muscle contractile properties

KW - muscle force

KW - nasal dilator muscles

UR - http://www.scopus.com/inward/record.url?scp=0029151798&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029151798&partnerID=8YFLogxK

M3 - Article

C2 - 7559231

AN - SCOPUS:0029151798

VL - 79

SP - 270

EP - 278

JO - Journal of Applied Physiology

JF - Journal of Applied Physiology

SN - 8750-7587

IS - 1

ER -