Molecular interferometric imaging biosensor

Ming Zhao, David Nolte

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

We present molecular interferometric imaging (MI2) as a new sensing technique for direct detection of biomolecules that is easier and more sensitive than surface plasmon resonance and scalable to hundreds of assays per chip.

Original languageEnglish (US)
Title of host publicationOptics InfoBase Conference Papers
PublisherOptical Society of America
ISBN (Print)1557528349, 9781557528346
StatePublished - 2007
Externally publishedYes
EventConference on Lasers and Electro-Optics, CLEO 2007 - Baltimore, MD, United States
Duration: May 6 2007May 6 2007

Other

OtherConference on Lasers and Electro-Optics, CLEO 2007
CountryUnited States
CityBaltimore, MD
Period5/6/075/6/07

Fingerprint

Molecular imaging
Surface plasmon resonance
Biomolecules
bioinstrumentation
Biosensors
Assays
surface plasmon resonance
chips

ASJC Scopus subject areas

  • Instrumentation
  • Atomic and Molecular Physics, and Optics

Cite this

Zhao, M., & Nolte, D. (2007). Molecular interferometric imaging biosensor. In Optics InfoBase Conference Papers Optical Society of America.

Molecular interferometric imaging biosensor. / Zhao, Ming; Nolte, David.

Optics InfoBase Conference Papers. Optical Society of America, 2007.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Zhao, M & Nolte, D 2007, Molecular interferometric imaging biosensor. in Optics InfoBase Conference Papers. Optical Society of America, Conference on Lasers and Electro-Optics, CLEO 2007, Baltimore, MD, United States, 5/6/07.
Zhao M, Nolte D. Molecular interferometric imaging biosensor. In Optics InfoBase Conference Papers. Optical Society of America. 2007
Zhao, Ming ; Nolte, David. / Molecular interferometric imaging biosensor. Optics InfoBase Conference Papers. Optical Society of America, 2007.
@inproceedings{923bff684c584c32b6d0c1766a73cfa2,
title = "Molecular interferometric imaging biosensor",
abstract = "We present molecular interferometric imaging (MI2) as a new sensing technique for direct detection of biomolecules that is easier and more sensitive than surface plasmon resonance and scalable to hundreds of assays per chip.",
author = "Ming Zhao and David Nolte",
year = "2007",
language = "English (US)",
isbn = "1557528349",
booktitle = "Optics InfoBase Conference Papers",
publisher = "Optical Society of America",

}

TY - GEN

T1 - Molecular interferometric imaging biosensor

AU - Zhao, Ming

AU - Nolte, David

PY - 2007

Y1 - 2007

N2 - We present molecular interferometric imaging (MI2) as a new sensing technique for direct detection of biomolecules that is easier and more sensitive than surface plasmon resonance and scalable to hundreds of assays per chip.

AB - We present molecular interferometric imaging (MI2) as a new sensing technique for direct detection of biomolecules that is easier and more sensitive than surface plasmon resonance and scalable to hundreds of assays per chip.

UR - http://www.scopus.com/inward/record.url?scp=84898991504&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84898991504&partnerID=8YFLogxK

M3 - Conference contribution

SN - 1557528349

SN - 9781557528346

BT - Optics InfoBase Conference Papers

PB - Optical Society of America

ER -