Noise characteristics of U. S. synchrotron radiation sources

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Noise characteristics of the U. S. x-ray synchrotron sources are compared in the 0-2.5-kHz region. In general, little difference is found in the characteristic frequencies of the noise on focused and unfocused beamlines of a particular source, but the magnitude and white-noise levels differ. The National Synchrotron Light Source shows the least characteristic noise and the noise that is observed is small in magnitude (2-3 times the white-noise level).

Original languageEnglish (US)
Pages (from-to)3024-3026
Number of pages3
JournalReview of Scientific Instruments
Volume57
Issue number12
DOIs
StatePublished - 1986
Externally publishedYes

Fingerprint

White noise
Synchrotron radiation
radiation sources
Synchrotrons
synchrotron radiation
white noise
Light sources
synchrotrons
X rays
light sources
x rays

ASJC Scopus subject areas

  • Instrumentation
  • Physics and Astronomy (miscellaneous)

Cite this

Noise characteristics of U. S. synchrotron radiation sources. / Powers, Linda S.

In: Review of Scientific Instruments, Vol. 57, No. 12, 1986, p. 3024-3026.

Research output: Contribution to journalArticle

@article{9c87813d91fa4ed9bb9f1f0d5e086342,
title = "Noise characteristics of U. S. synchrotron radiation sources",
abstract = "Noise characteristics of the U. S. x-ray synchrotron sources are compared in the 0-2.5-kHz region. In general, little difference is found in the characteristic frequencies of the noise on focused and unfocused beamlines of a particular source, but the magnitude and white-noise levels differ. The National Synchrotron Light Source shows the least characteristic noise and the noise that is observed is small in magnitude (2-3 times the white-noise level).",
author = "Powers, {Linda S}",
year = "1986",
doi = "10.1063/1.1138985",
language = "English (US)",
volume = "57",
pages = "3024--3026",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "12",

}

TY - JOUR

T1 - Noise characteristics of U. S. synchrotron radiation sources

AU - Powers, Linda S

PY - 1986

Y1 - 1986

N2 - Noise characteristics of the U. S. x-ray synchrotron sources are compared in the 0-2.5-kHz region. In general, little difference is found in the characteristic frequencies of the noise on focused and unfocused beamlines of a particular source, but the magnitude and white-noise levels differ. The National Synchrotron Light Source shows the least characteristic noise and the noise that is observed is small in magnitude (2-3 times the white-noise level).

AB - Noise characteristics of the U. S. x-ray synchrotron sources are compared in the 0-2.5-kHz region. In general, little difference is found in the characteristic frequencies of the noise on focused and unfocused beamlines of a particular source, but the magnitude and white-noise levels differ. The National Synchrotron Light Source shows the least characteristic noise and the noise that is observed is small in magnitude (2-3 times the white-noise level).

UR - http://www.scopus.com/inward/record.url?scp=36549097518&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=36549097518&partnerID=8YFLogxK

U2 - 10.1063/1.1138985

DO - 10.1063/1.1138985

M3 - Article

AN - SCOPUS:36549097518

VL - 57

SP - 3024

EP - 3026

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 12

ER -