The shape parameter, A, has been used to assess hypoxic sensitivity (ventilatory response, V ̇E, to lowered alveolar oxygen tension, PAO2) in the model of the form V ̇E = V ̇EO + A (PAO2 - C) where C is held constant at 32. In this paper we examine the consequence of holding C constant versus estimating both A and C from the data. Using computer-simulated data from 59 subjects whose A and C values had been previously determined, we indicate that when the actual C value is substantially different from 32, the model with C = 32 does not fit the data. In this case, the estimated A value with C = 32 is highly dependent upon the lowest value of PAO2 obtained in the experimental protocol and can be markedly different from the actual A value. In contrast, when C is also estimated from the subject's data the model fits the data and the estimate of A is unbiased but the precision may be diminished when the actual value of C is low. To improve this precision, we propose a Bayesian estimation scheme that adds a "soft" constraint on C.

Original languageEnglish (US)
Pages (from-to)553-562
Number of pages10
JournalComputers and Biomedical Research
Volume18
Issue number6
DOIs
StatePublished - 1985
Externally publishedYes

Fingerprint

Oxygen
caN protocol

ASJC Scopus subject areas

  • Medicine (miscellaneous)

Cite this

On the estimation of hypoxic ventilatory response. / Engeman, Richard M.; Sherrill, Duane L; Swanson, George D.

In: Computers and Biomedical Research, Vol. 18, No. 6, 1985, p. 553-562.

Research output: Contribution to journalArticle

Engeman, Richard M. ; Sherrill, Duane L ; Swanson, George D. / On the estimation of hypoxic ventilatory response. In: Computers and Biomedical Research. 1985 ; Vol. 18, No. 6. pp. 553-562.
@article{abad5274873c48c181a3a837b23150b4,
title = "On the estimation of hypoxic ventilatory response",
abstract = "The shape parameter, A, has been used to assess hypoxic sensitivity (ventilatory response, V ̇E, to lowered alveolar oxygen tension, PAO2) in the model of the form V ̇E = V ̇EO + A (PAO2 - C) where C is held constant at 32. In this paper we examine the consequence of holding C constant versus estimating both A and C from the data. Using computer-simulated data from 59 subjects whose A and C values had been previously determined, we indicate that when the actual C value is substantially different from 32, the model with C = 32 does not fit the data. In this case, the estimated A value with C = 32 is highly dependent upon the lowest value of PAO2 obtained in the experimental protocol and can be markedly different from the actual A value. In contrast, when C is also estimated from the subject's data the model fits the data and the estimate of A is unbiased but the precision may be diminished when the actual value of C is low. To improve this precision, we propose a Bayesian estimation scheme that adds a {"}soft{"} constraint on C.",
author = "Engeman, {Richard M.} and Sherrill, {Duane L} and Swanson, {George D.}",
year = "1985",
doi = "10.1016/0010-4809(85)90030-8",
language = "English (US)",
volume = "18",
pages = "553--562",
journal = "Journal of Biomedical Informatics",
issn = "1532-0464",
publisher = "Academic Press Inc.",
number = "6",

}

TY - JOUR

T1 - On the estimation of hypoxic ventilatory response

AU - Engeman, Richard M.

AU - Sherrill, Duane L

AU - Swanson, George D.

PY - 1985

Y1 - 1985

N2 - The shape parameter, A, has been used to assess hypoxic sensitivity (ventilatory response, V ̇E, to lowered alveolar oxygen tension, PAO2) in the model of the form V ̇E = V ̇EO + A (PAO2 - C) where C is held constant at 32. In this paper we examine the consequence of holding C constant versus estimating both A and C from the data. Using computer-simulated data from 59 subjects whose A and C values had been previously determined, we indicate that when the actual C value is substantially different from 32, the model with C = 32 does not fit the data. In this case, the estimated A value with C = 32 is highly dependent upon the lowest value of PAO2 obtained in the experimental protocol and can be markedly different from the actual A value. In contrast, when C is also estimated from the subject's data the model fits the data and the estimate of A is unbiased but the precision may be diminished when the actual value of C is low. To improve this precision, we propose a Bayesian estimation scheme that adds a "soft" constraint on C.

AB - The shape parameter, A, has been used to assess hypoxic sensitivity (ventilatory response, V ̇E, to lowered alveolar oxygen tension, PAO2) in the model of the form V ̇E = V ̇EO + A (PAO2 - C) where C is held constant at 32. In this paper we examine the consequence of holding C constant versus estimating both A and C from the data. Using computer-simulated data from 59 subjects whose A and C values had been previously determined, we indicate that when the actual C value is substantially different from 32, the model with C = 32 does not fit the data. In this case, the estimated A value with C = 32 is highly dependent upon the lowest value of PAO2 obtained in the experimental protocol and can be markedly different from the actual A value. In contrast, when C is also estimated from the subject's data the model fits the data and the estimate of A is unbiased but the precision may be diminished when the actual value of C is low. To improve this precision, we propose a Bayesian estimation scheme that adds a "soft" constraint on C.

UR - http://www.scopus.com/inward/record.url?scp=0022352568&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022352568&partnerID=8YFLogxK

U2 - 10.1016/0010-4809(85)90030-8

DO - 10.1016/0010-4809(85)90030-8

M3 - Article

C2 - 4075789

AN - SCOPUS:0022352568

VL - 18

SP - 553

EP - 562

JO - Journal of Biomedical Informatics

JF - Journal of Biomedical Informatics

SN - 1532-0464

IS - 6

ER -