Isotope-ratio measurements are necessary in a wide range of applications. The precision of these measurements is of utmost importance because it governs the ability to distinguish differences between samples. Often, simultaneous isotope detection is necessary to reach the precision values needed for an analysis to be conclusive. Furthermore, the more isotope ratios that can be precisely determined at once, the better the chances of distinguishing between samples. Therefore, detector arrays, able to simultaneously monitor a broad range of isotopes, are attractive. Such an array detector, termed the focal plane camera (FPC), has been shown to be capable of achieving impressive precision values (0.02% RSD) within relatively short integration times (200 s). However, because the channels of the FPC array detector are inherently discrete, optimization of peak integration methods is important. This paper compares isotope-ratio precision values based on different peak integration methods of raw and zero-filled interpolated data. Also, problems associated with peak drift are explored and the use of flat-topped peak shapes for improved isotope-ratio precision levels are investigated.

Original languageEnglish (US)
Pages (from-to)322-327
Number of pages6
JournalJournal of Analytical Atomic Spectrometry
Volume25
Issue number3
DOIs
StatePublished - 2010

Fingerprint

Spectrographs
Isotopes
Detectors
Cameras

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Optimization of Ag isotope-ratio precision with a 128-channel array detector coupled to a mattauch-herzog mass spectrograph. / Schilling, Gregory D.; Ray, Steven J.; Sperline, Roger P.; Denton, M Bonner; Barinaga, Charles J.; Koppenaal, David W.; Hieftje, Gary M.

In: Journal of Analytical Atomic Spectrometry, Vol. 25, No. 3, 2010, p. 322-327.

Research output: Contribution to journalArticle

Schilling, Gregory D. ; Ray, Steven J. ; Sperline, Roger P. ; Denton, M Bonner ; Barinaga, Charles J. ; Koppenaal, David W. ; Hieftje, Gary M. / Optimization of Ag isotope-ratio precision with a 128-channel array detector coupled to a mattauch-herzog mass spectrograph. In: Journal of Analytical Atomic Spectrometry. 2010 ; Vol. 25, No. 3. pp. 322-327.
@article{19e4d8627fd84a3d9d3da5d79ff06998,
title = "Optimization of Ag isotope-ratio precision with a 128-channel array detector coupled to a mattauch-herzog mass spectrograph",
abstract = "Isotope-ratio measurements are necessary in a wide range of applications. The precision of these measurements is of utmost importance because it governs the ability to distinguish differences between samples. Often, simultaneous isotope detection is necessary to reach the precision values needed for an analysis to be conclusive. Furthermore, the more isotope ratios that can be precisely determined at once, the better the chances of distinguishing between samples. Therefore, detector arrays, able to simultaneously monitor a broad range of isotopes, are attractive. Such an array detector, termed the focal plane camera (FPC), has been shown to be capable of achieving impressive precision values (0.02{\%} RSD) within relatively short integration times (200 s). However, because the channels of the FPC array detector are inherently discrete, optimization of peak integration methods is important. This paper compares isotope-ratio precision values based on different peak integration methods of raw and zero-filled interpolated data. Also, problems associated with peak drift are explored and the use of flat-topped peak shapes for improved isotope-ratio precision levels are investigated.",
author = "Schilling, {Gregory D.} and Ray, {Steven J.} and Sperline, {Roger P.} and Denton, {M Bonner} and Barinaga, {Charles J.} and Koppenaal, {David W.} and Hieftje, {Gary M.}",
year = "2010",
doi = "10.1039/b914052b",
language = "English (US)",
volume = "25",
pages = "322--327",
journal = "Journal of Analytical Atomic Spectrometry",
issn = "0267-9477",
publisher = "Royal Society of Chemistry",
number = "3",

}

TY - JOUR

T1 - Optimization of Ag isotope-ratio precision with a 128-channel array detector coupled to a mattauch-herzog mass spectrograph

AU - Schilling, Gregory D.

AU - Ray, Steven J.

AU - Sperline, Roger P.

AU - Denton, M Bonner

AU - Barinaga, Charles J.

AU - Koppenaal, David W.

AU - Hieftje, Gary M.

PY - 2010

Y1 - 2010

N2 - Isotope-ratio measurements are necessary in a wide range of applications. The precision of these measurements is of utmost importance because it governs the ability to distinguish differences between samples. Often, simultaneous isotope detection is necessary to reach the precision values needed for an analysis to be conclusive. Furthermore, the more isotope ratios that can be precisely determined at once, the better the chances of distinguishing between samples. Therefore, detector arrays, able to simultaneously monitor a broad range of isotopes, are attractive. Such an array detector, termed the focal plane camera (FPC), has been shown to be capable of achieving impressive precision values (0.02% RSD) within relatively short integration times (200 s). However, because the channels of the FPC array detector are inherently discrete, optimization of peak integration methods is important. This paper compares isotope-ratio precision values based on different peak integration methods of raw and zero-filled interpolated data. Also, problems associated with peak drift are explored and the use of flat-topped peak shapes for improved isotope-ratio precision levels are investigated.

AB - Isotope-ratio measurements are necessary in a wide range of applications. The precision of these measurements is of utmost importance because it governs the ability to distinguish differences between samples. Often, simultaneous isotope detection is necessary to reach the precision values needed for an analysis to be conclusive. Furthermore, the more isotope ratios that can be precisely determined at once, the better the chances of distinguishing between samples. Therefore, detector arrays, able to simultaneously monitor a broad range of isotopes, are attractive. Such an array detector, termed the focal plane camera (FPC), has been shown to be capable of achieving impressive precision values (0.02% RSD) within relatively short integration times (200 s). However, because the channels of the FPC array detector are inherently discrete, optimization of peak integration methods is important. This paper compares isotope-ratio precision values based on different peak integration methods of raw and zero-filled interpolated data. Also, problems associated with peak drift are explored and the use of flat-topped peak shapes for improved isotope-ratio precision levels are investigated.

UR - http://www.scopus.com/inward/record.url?scp=77649219922&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77649219922&partnerID=8YFLogxK

U2 - 10.1039/b914052b

DO - 10.1039/b914052b

M3 - Article

AN - SCOPUS:77649219922

VL - 25

SP - 322

EP - 327

JO - Journal of Analytical Atomic Spectrometry

JF - Journal of Analytical Atomic Spectrometry

SN - 0267-9477

IS - 3

ER -