Abstract

This study reports the design, prototyping, and assay development of multiplexed polymerase chain reaction (PCR) on a plastic microfluidic device. Amplification of 17 DNA loci is carried out directly on-chip as part of a system for continuous workflow processing from sample preparation (SP) to capillary electrophoresis (CE). For enhanced performance of on-chip PCR amplification, improved control systems have been developed making use of customized Peltier assemblies, valve actuators, software, and amplification chemistry protocols. Multiple enhancements to the microfluidic chip design have been enacted to improve the reliability of sample delivery through the various on-chip modules. This work has been enabled by the encapsulation of PCR reagents into a solid phase material through an optimized Solid Phase Encapsulating Assay Mix (SPEAM) bead-based hydrogel fabrication process. SPEAM bead technology is reliably coupled with precise microfluidic metering and dispensing for efficient amplification and subsequent DNA short tandem repeat (STR) fragment analysis. This provides a means of on-chip reagent storage suitable for microfluidic automation, with the long shelf-life necessary for point-of-care (POC) or field deployable applications. This paper reports the first high quality 17-plex forensic STR amplification from a reference sample in a microfluidic chip with preloaded solid phase reagents, that is designed for integration with up and downstream processing.

Original languageEnglish (US)
Pages (from-to)5510-5519
Number of pages10
JournalAnalyst
Volume137
Issue number23
DOIs
StatePublished - 2012

Fingerprint

Microfluidics
Polymerase chain reaction
polymerase chain reaction
Amplification
amplification
DNA
Polymerase Chain Reaction
Lab-On-A-Chip Devices
Assays
Microsatellite Repeats
assay
Point-of-Care Systems
Workflow
Hydrogel
Automation
Capillary Electrophoresis
Capillary electrophoresis
reference sample
encapsulation
Plastics

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy
  • Electrochemistry
  • Biochemistry
  • Environmental Chemistry

Cite this

Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis. / Estes, Matthew D.; Yang, Jianing; Duane, Brett; Smith, Stan; Brooks, Carla; Nordquist, Alan; Zenhausern, Frederic.

In: Analyst, Vol. 137, No. 23, 2012, p. 5510-5519.

Research output: Contribution to journalArticle

Estes, MD, Yang, J, Duane, B, Smith, S, Brooks, C, Nordquist, A & Zenhausern, F 2012, 'Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis', Analyst, vol. 137, no. 23, pp. 5510-5519. https://doi.org/10.1039/c2an35768b
Estes, Matthew D. ; Yang, Jianing ; Duane, Brett ; Smith, Stan ; Brooks, Carla ; Nordquist, Alan ; Zenhausern, Frederic. / Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis. In: Analyst. 2012 ; Vol. 137, No. 23. pp. 5510-5519.
@article{91bdfbe614974b47a155b5c43b0323eb,
title = "Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis",
abstract = "This study reports the design, prototyping, and assay development of multiplexed polymerase chain reaction (PCR) on a plastic microfluidic device. Amplification of 17 DNA loci is carried out directly on-chip as part of a system for continuous workflow processing from sample preparation (SP) to capillary electrophoresis (CE). For enhanced performance of on-chip PCR amplification, improved control systems have been developed making use of customized Peltier assemblies, valve actuators, software, and amplification chemistry protocols. Multiple enhancements to the microfluidic chip design have been enacted to improve the reliability of sample delivery through the various on-chip modules. This work has been enabled by the encapsulation of PCR reagents into a solid phase material through an optimized Solid Phase Encapsulating Assay Mix (SPEAM) bead-based hydrogel fabrication process. SPEAM bead technology is reliably coupled with precise microfluidic metering and dispensing for efficient amplification and subsequent DNA short tandem repeat (STR) fragment analysis. This provides a means of on-chip reagent storage suitable for microfluidic automation, with the long shelf-life necessary for point-of-care (POC) or field deployable applications. This paper reports the first high quality 17-plex forensic STR amplification from a reference sample in a microfluidic chip with preloaded solid phase reagents, that is designed for integration with up and downstream processing.",
author = "Estes, {Matthew D.} and Jianing Yang and Brett Duane and Stan Smith and Carla Brooks and Alan Nordquist and Frederic Zenhausern",
year = "2012",
doi = "10.1039/c2an35768b",
language = "English (US)",
volume = "137",
pages = "5510--5519",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "23",

}

TY - JOUR

T1 - Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis

AU - Estes, Matthew D.

AU - Yang, Jianing

AU - Duane, Brett

AU - Smith, Stan

AU - Brooks, Carla

AU - Nordquist, Alan

AU - Zenhausern, Frederic

PY - 2012

Y1 - 2012

N2 - This study reports the design, prototyping, and assay development of multiplexed polymerase chain reaction (PCR) on a plastic microfluidic device. Amplification of 17 DNA loci is carried out directly on-chip as part of a system for continuous workflow processing from sample preparation (SP) to capillary electrophoresis (CE). For enhanced performance of on-chip PCR amplification, improved control systems have been developed making use of customized Peltier assemblies, valve actuators, software, and amplification chemistry protocols. Multiple enhancements to the microfluidic chip design have been enacted to improve the reliability of sample delivery through the various on-chip modules. This work has been enabled by the encapsulation of PCR reagents into a solid phase material through an optimized Solid Phase Encapsulating Assay Mix (SPEAM) bead-based hydrogel fabrication process. SPEAM bead technology is reliably coupled with precise microfluidic metering and dispensing for efficient amplification and subsequent DNA short tandem repeat (STR) fragment analysis. This provides a means of on-chip reagent storage suitable for microfluidic automation, with the long shelf-life necessary for point-of-care (POC) or field deployable applications. This paper reports the first high quality 17-plex forensic STR amplification from a reference sample in a microfluidic chip with preloaded solid phase reagents, that is designed for integration with up and downstream processing.

AB - This study reports the design, prototyping, and assay development of multiplexed polymerase chain reaction (PCR) on a plastic microfluidic device. Amplification of 17 DNA loci is carried out directly on-chip as part of a system for continuous workflow processing from sample preparation (SP) to capillary electrophoresis (CE). For enhanced performance of on-chip PCR amplification, improved control systems have been developed making use of customized Peltier assemblies, valve actuators, software, and amplification chemistry protocols. Multiple enhancements to the microfluidic chip design have been enacted to improve the reliability of sample delivery through the various on-chip modules. This work has been enabled by the encapsulation of PCR reagents into a solid phase material through an optimized Solid Phase Encapsulating Assay Mix (SPEAM) bead-based hydrogel fabrication process. SPEAM bead technology is reliably coupled with precise microfluidic metering and dispensing for efficient amplification and subsequent DNA short tandem repeat (STR) fragment analysis. This provides a means of on-chip reagent storage suitable for microfluidic automation, with the long shelf-life necessary for point-of-care (POC) or field deployable applications. This paper reports the first high quality 17-plex forensic STR amplification from a reference sample in a microfluidic chip with preloaded solid phase reagents, that is designed for integration with up and downstream processing.

UR - http://www.scopus.com/inward/record.url?scp=84876740813&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84876740813&partnerID=8YFLogxK

U2 - 10.1039/c2an35768b

DO - 10.1039/c2an35768b

M3 - Article

VL - 137

SP - 5510

EP - 5519

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 23

ER -