Cathode Ray Tube (CRT) displays and Active-Matrix Liquid Crystal Displays (AM-LCD) are currently the dominant softcopy displays in the radiology reading rooms. Results of some studies have shown the superiority of LCDs over CRTs in many aspects. In terms of the contrast resolution, however, they are similar and both of them can usually interpret 8-bit images. We have reported an error-diffusion-based method to compensate for the limited contrast resolution last year on this meeting. In this paper, we propose to include the image content into the error diffusion kernel to further increase the contrast of the image displayed. First, the raw image is processed to find the image contrast information. The areas in the image which have low contrast are enhanced more than the areas with high contrast. The areas where image noise is dominant are not enhanced. The enhancement operation will modify the image and the changes are treated as error and inputted to the error diffusion kernel. We have used a different set of diffusion weights for image contrast enhancement. But the two diffusion operations are done together.

Original languageEnglish (US)
Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6141
DOIs
StatePublished - 2006
EventMedical Imaging 2006: Visualization, Image-Guided Procedures, and Display - San Diego, CA, United States
Duration: Feb 12 2006Feb 14 2006

Other

OtherMedical Imaging 2006: Visualization, Image-Guided Procedures, and Display
CountryUnited States
CitySan Diego, CA
Period2/12/062/14/06

Fingerprint

Display devices
Cathode ray tubes
Liquid crystal displays
Radiology

Keywords

  • Contrast Enhancement
  • Contrast Resolution
  • Error Diffusion
  • Softcopy Display

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Fan, J., Roehrig, H., Sundareshan, M. K., & Krupinski, E. A. (2006). Optimizing the image contrast on the softcopy displays. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 6141). [61410W] https://doi.org/10.1117/12.656062

Optimizing the image contrast on the softcopy displays. / Fan, Jiahua; Roehrig, Hans; Sundareshan, Malur K.; Krupinski, Elizabeth A.

Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 6141 2006. 61410W.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Fan, J, Roehrig, H, Sundareshan, MK & Krupinski, EA 2006, Optimizing the image contrast on the softcopy displays. in Progress in Biomedical Optics and Imaging - Proceedings of SPIE. vol. 6141, 61410W, Medical Imaging 2006: Visualization, Image-Guided Procedures, and Display, San Diego, CA, United States, 2/12/06. https://doi.org/10.1117/12.656062
Fan J, Roehrig H, Sundareshan MK, Krupinski EA. Optimizing the image contrast on the softcopy displays. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 6141. 2006. 61410W https://doi.org/10.1117/12.656062
Fan, Jiahua ; Roehrig, Hans ; Sundareshan, Malur K. ; Krupinski, Elizabeth A. / Optimizing the image contrast on the softcopy displays. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 6141 2006.
@inproceedings{068bb63bc4c342289db187c18c473781,
title = "Optimizing the image contrast on the softcopy displays",
abstract = "Cathode Ray Tube (CRT) displays and Active-Matrix Liquid Crystal Displays (AM-LCD) are currently the dominant softcopy displays in the radiology reading rooms. Results of some studies have shown the superiority of LCDs over CRTs in many aspects. In terms of the contrast resolution, however, they are similar and both of them can usually interpret 8-bit images. We have reported an error-diffusion-based method to compensate for the limited contrast resolution last year on this meeting. In this paper, we propose to include the image content into the error diffusion kernel to further increase the contrast of the image displayed. First, the raw image is processed to find the image contrast information. The areas in the image which have low contrast are enhanced more than the areas with high contrast. The areas where image noise is dominant are not enhanced. The enhancement operation will modify the image and the changes are treated as error and inputted to the error diffusion kernel. We have used a different set of diffusion weights for image contrast enhancement. But the two diffusion operations are done together.",
keywords = "Contrast Enhancement, Contrast Resolution, Error Diffusion, Softcopy Display",
author = "Jiahua Fan and Hans Roehrig and Sundareshan, {Malur K.} and Krupinski, {Elizabeth A}",
year = "2006",
doi = "10.1117/12.656062",
language = "English (US)",
isbn = "0819461849",
volume = "6141",
booktitle = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",

}

TY - GEN

T1 - Optimizing the image contrast on the softcopy displays

AU - Fan, Jiahua

AU - Roehrig, Hans

AU - Sundareshan, Malur K.

AU - Krupinski, Elizabeth A

PY - 2006

Y1 - 2006

N2 - Cathode Ray Tube (CRT) displays and Active-Matrix Liquid Crystal Displays (AM-LCD) are currently the dominant softcopy displays in the radiology reading rooms. Results of some studies have shown the superiority of LCDs over CRTs in many aspects. In terms of the contrast resolution, however, they are similar and both of them can usually interpret 8-bit images. We have reported an error-diffusion-based method to compensate for the limited contrast resolution last year on this meeting. In this paper, we propose to include the image content into the error diffusion kernel to further increase the contrast of the image displayed. First, the raw image is processed to find the image contrast information. The areas in the image which have low contrast are enhanced more than the areas with high contrast. The areas where image noise is dominant are not enhanced. The enhancement operation will modify the image and the changes are treated as error and inputted to the error diffusion kernel. We have used a different set of diffusion weights for image contrast enhancement. But the two diffusion operations are done together.

AB - Cathode Ray Tube (CRT) displays and Active-Matrix Liquid Crystal Displays (AM-LCD) are currently the dominant softcopy displays in the radiology reading rooms. Results of some studies have shown the superiority of LCDs over CRTs in many aspects. In terms of the contrast resolution, however, they are similar and both of them can usually interpret 8-bit images. We have reported an error-diffusion-based method to compensate for the limited contrast resolution last year on this meeting. In this paper, we propose to include the image content into the error diffusion kernel to further increase the contrast of the image displayed. First, the raw image is processed to find the image contrast information. The areas in the image which have low contrast are enhanced more than the areas with high contrast. The areas where image noise is dominant are not enhanced. The enhancement operation will modify the image and the changes are treated as error and inputted to the error diffusion kernel. We have used a different set of diffusion weights for image contrast enhancement. But the two diffusion operations are done together.

KW - Contrast Enhancement

KW - Contrast Resolution

KW - Error Diffusion

KW - Softcopy Display

UR - http://www.scopus.com/inward/record.url?scp=33745386347&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745386347&partnerID=8YFLogxK

U2 - 10.1117/12.656062

DO - 10.1117/12.656062

M3 - Conference contribution

SN - 0819461849

SN - 9780819461841

VL - 6141

BT - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

ER -