Parametric polariton amplification in semiconductor microcavities

G. Messin, J. Karr, A. Baas, Galina Khitrova, R. Houdré, R. P. Stanley, U. Oesterle, E. Giacobino

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Parametric amplification in semiconductor microcavities was studied. Using homodyne detection in a degenerate configuration, evidence was shown for specific features of polariton four-wave mixing in the microcavity. The amplification threshold and the shift of the emission line observed in other experiments were obtained in a configuration very different from that of other studies.

Original languageEnglish (US)
Article number127403
Pages (from-to)127403/1-127403/4
JournalPhysical Review Letters
Volume87
Issue number12
DOIs
StatePublished - Sep 17 2001

Fingerprint

polaritons
configurations
four-wave mixing
thresholds
shift

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Messin, G., Karr, J., Baas, A., Khitrova, G., Houdré, R., Stanley, R. P., ... Giacobino, E. (2001). Parametric polariton amplification in semiconductor microcavities. Physical Review Letters, 87(12), 127403/1-127403/4. [127403]. https://doi.org/10.1103/PhysRevLett.87.127403

Parametric polariton amplification in semiconductor microcavities. / Messin, G.; Karr, J.; Baas, A.; Khitrova, Galina; Houdré, R.; Stanley, R. P.; Oesterle, U.; Giacobino, E.

In: Physical Review Letters, Vol. 87, No. 12, 127403, 17.09.2001, p. 127403/1-127403/4.

Research output: Contribution to journalArticle

Messin, G, Karr, J, Baas, A, Khitrova, G, Houdré, R, Stanley, RP, Oesterle, U & Giacobino, E 2001, 'Parametric polariton amplification in semiconductor microcavities', Physical Review Letters, vol. 87, no. 12, 127403, pp. 127403/1-127403/4. https://doi.org/10.1103/PhysRevLett.87.127403
Messin G, Karr J, Baas A, Khitrova G, Houdré R, Stanley RP et al. Parametric polariton amplification in semiconductor microcavities. Physical Review Letters. 2001 Sep 17;87(12):127403/1-127403/4. 127403. https://doi.org/10.1103/PhysRevLett.87.127403
Messin, G. ; Karr, J. ; Baas, A. ; Khitrova, Galina ; Houdré, R. ; Stanley, R. P. ; Oesterle, U. ; Giacobino, E. / Parametric polariton amplification in semiconductor microcavities. In: Physical Review Letters. 2001 ; Vol. 87, No. 12. pp. 127403/1-127403/4.
@article{a0d6eaa962c746e19194c99a1a3c51ea,
title = "Parametric polariton amplification in semiconductor microcavities",
abstract = "Parametric amplification in semiconductor microcavities was studied. Using homodyne detection in a degenerate configuration, evidence was shown for specific features of polariton four-wave mixing in the microcavity. The amplification threshold and the shift of the emission line observed in other experiments were obtained in a configuration very different from that of other studies.",
author = "G. Messin and J. Karr and A. Baas and Galina Khitrova and R. Houdr{\'e} and Stanley, {R. P.} and U. Oesterle and E. Giacobino",
year = "2001",
month = "9",
day = "17",
doi = "10.1103/PhysRevLett.87.127403",
language = "English (US)",
volume = "87",
pages = "127403/1--127403/4",
journal = "Physical Review Letters",
issn = "0031-9007",
publisher = "American Physical Society",
number = "12",

}

TY - JOUR

T1 - Parametric polariton amplification in semiconductor microcavities

AU - Messin, G.

AU - Karr, J.

AU - Baas, A.

AU - Khitrova, Galina

AU - Houdré, R.

AU - Stanley, R. P.

AU - Oesterle, U.

AU - Giacobino, E.

PY - 2001/9/17

Y1 - 2001/9/17

N2 - Parametric amplification in semiconductor microcavities was studied. Using homodyne detection in a degenerate configuration, evidence was shown for specific features of polariton four-wave mixing in the microcavity. The amplification threshold and the shift of the emission line observed in other experiments were obtained in a configuration very different from that of other studies.

AB - Parametric amplification in semiconductor microcavities was studied. Using homodyne detection in a degenerate configuration, evidence was shown for specific features of polariton four-wave mixing in the microcavity. The amplification threshold and the shift of the emission line observed in other experiments were obtained in a configuration very different from that of other studies.

UR - http://www.scopus.com/inward/record.url?scp=84988751809&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84988751809&partnerID=8YFLogxK

U2 - 10.1103/PhysRevLett.87.127403

DO - 10.1103/PhysRevLett.87.127403

M3 - Article

AN - SCOPUS:84988751809

VL - 87

SP - 127403/1-127403/4

JO - Physical Review Letters

JF - Physical Review Letters

SN - 0031-9007

IS - 12

M1 - 127403

ER -