Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast

Initial clinical experience

Kambiz Nael, Mayil Krishnam, Ali Nael, Anthony Ton, Stefan G. Ruehm, J. Paul Finn

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

To investigate a high spatial resolution peripheral contrast-enhanced MR angiography (CE-MRA) protocol, applying a dedicated multi-channel array coil and accelerated parallel acquisition at 3.0T in evaluation of patients with peripheral vascular disease. Twenty patients with peripheral vascular disease underwent multi-station high spatial resolution peripheral CE-MRA at 3T. The image quality, presence of venous contamination, image noise, and artifact were evaluated by 2 radiologists independently. Assessment of arterial disease for 540 arterial segments was performed, and findings were correlated with conventional catheter angiography in 10 patients. All studies were yielded high diagnostic image quality. Venous contamination and artifact were minimal and never interfered with diagnosis. Sixty seven arterial segments with significant stenoses (>0%) were detected by observers with excellent interobserver agreement (Κ=0.82; 95% CI: 0.76, 0.88). There was a significant correlation between CE-MRA and conventional angiography (Rs=0.91 and 0.94 for reader 1 and 2, respectively) for the assessment of the degree of stenosis. Higher available SNR at 3T in combination with multi-coil technology and accelerated parallel acquisition, result in acquisition of nearly isotropic submillimeter 3D voxels throughout the entire peripheral arterial tree with diagnostic image quality and favorable comparative analysis with catheter angiography.

Original languageEnglish (US)
Pages (from-to)2893-2900
Number of pages8
JournalEuropean Radiology
Volume18
Issue number12
DOIs
StatePublished - 2008
Externally publishedYes

Fingerprint

Angiography
Peripheral Vascular Diseases
Artifacts
Pathologic Constriction
Catheters
Technology

Keywords

  • 3.0T or high magnetic field
  • Atherosclerosis
  • Low dose contrast
  • Multi-coil technology
  • Peripheral MRA

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast : Initial clinical experience. / Nael, Kambiz; Krishnam, Mayil; Nael, Ali; Ton, Anthony; Ruehm, Stefan G.; Finn, J. Paul.

In: European Radiology, Vol. 18, No. 12, 2008, p. 2893-2900.

Research output: Contribution to journalArticle

Nael, Kambiz ; Krishnam, Mayil ; Nael, Ali ; Ton, Anthony ; Ruehm, Stefan G. ; Finn, J. Paul. / Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast : Initial clinical experience. In: European Radiology. 2008 ; Vol. 18, No. 12. pp. 2893-2900.
@article{549a626b15ae416c8391f0a1014c2771,
title = "Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast: Initial clinical experience",
abstract = "To investigate a high spatial resolution peripheral contrast-enhanced MR angiography (CE-MRA) protocol, applying a dedicated multi-channel array coil and accelerated parallel acquisition at 3.0T in evaluation of patients with peripheral vascular disease. Twenty patients with peripheral vascular disease underwent multi-station high spatial resolution peripheral CE-MRA at 3T. The image quality, presence of venous contamination, image noise, and artifact were evaluated by 2 radiologists independently. Assessment of arterial disease for 540 arterial segments was performed, and findings were correlated with conventional catheter angiography in 10 patients. All studies were yielded high diagnostic image quality. Venous contamination and artifact were minimal and never interfered with diagnosis. Sixty seven arterial segments with significant stenoses (>0{\%}) were detected by observers with excellent interobserver agreement (Κ=0.82; 95{\%} CI: 0.76, 0.88). There was a significant correlation between CE-MRA and conventional angiography (Rs=0.91 and 0.94 for reader 1 and 2, respectively) for the assessment of the degree of stenosis. Higher available SNR at 3T in combination with multi-coil technology and accelerated parallel acquisition, result in acquisition of nearly isotropic submillimeter 3D voxels throughout the entire peripheral arterial tree with diagnostic image quality and favorable comparative analysis with catheter angiography.",
keywords = "3.0T or high magnetic field, Atherosclerosis, Low dose contrast, Multi-coil technology, Peripheral MRA",
author = "Kambiz Nael and Mayil Krishnam and Ali Nael and Anthony Ton and Ruehm, {Stefan G.} and Finn, {J. Paul}",
year = "2008",
doi = "10.1007/s00330-008-1074-y",
language = "English (US)",
volume = "18",
pages = "2893--2900",
journal = "European Radiology",
issn = "0938-7994",
publisher = "Springer Verlag",
number = "12",

}

TY - JOUR

T1 - Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast

T2 - Initial clinical experience

AU - Nael, Kambiz

AU - Krishnam, Mayil

AU - Nael, Ali

AU - Ton, Anthony

AU - Ruehm, Stefan G.

AU - Finn, J. Paul

PY - 2008

Y1 - 2008

N2 - To investigate a high spatial resolution peripheral contrast-enhanced MR angiography (CE-MRA) protocol, applying a dedicated multi-channel array coil and accelerated parallel acquisition at 3.0T in evaluation of patients with peripheral vascular disease. Twenty patients with peripheral vascular disease underwent multi-station high spatial resolution peripheral CE-MRA at 3T. The image quality, presence of venous contamination, image noise, and artifact were evaluated by 2 radiologists independently. Assessment of arterial disease for 540 arterial segments was performed, and findings were correlated with conventional catheter angiography in 10 patients. All studies were yielded high diagnostic image quality. Venous contamination and artifact were minimal and never interfered with diagnosis. Sixty seven arterial segments with significant stenoses (>0%) were detected by observers with excellent interobserver agreement (Κ=0.82; 95% CI: 0.76, 0.88). There was a significant correlation between CE-MRA and conventional angiography (Rs=0.91 and 0.94 for reader 1 and 2, respectively) for the assessment of the degree of stenosis. Higher available SNR at 3T in combination with multi-coil technology and accelerated parallel acquisition, result in acquisition of nearly isotropic submillimeter 3D voxels throughout the entire peripheral arterial tree with diagnostic image quality and favorable comparative analysis with catheter angiography.

AB - To investigate a high spatial resolution peripheral contrast-enhanced MR angiography (CE-MRA) protocol, applying a dedicated multi-channel array coil and accelerated parallel acquisition at 3.0T in evaluation of patients with peripheral vascular disease. Twenty patients with peripheral vascular disease underwent multi-station high spatial resolution peripheral CE-MRA at 3T. The image quality, presence of venous contamination, image noise, and artifact were evaluated by 2 radiologists independently. Assessment of arterial disease for 540 arterial segments was performed, and findings were correlated with conventional catheter angiography in 10 patients. All studies were yielded high diagnostic image quality. Venous contamination and artifact were minimal and never interfered with diagnosis. Sixty seven arterial segments with significant stenoses (>0%) were detected by observers with excellent interobserver agreement (Κ=0.82; 95% CI: 0.76, 0.88). There was a significant correlation between CE-MRA and conventional angiography (Rs=0.91 and 0.94 for reader 1 and 2, respectively) for the assessment of the degree of stenosis. Higher available SNR at 3T in combination with multi-coil technology and accelerated parallel acquisition, result in acquisition of nearly isotropic submillimeter 3D voxels throughout the entire peripheral arterial tree with diagnostic image quality and favorable comparative analysis with catheter angiography.

KW - 3.0T or high magnetic field

KW - Atherosclerosis

KW - Low dose contrast

KW - Multi-coil technology

KW - Peripheral MRA

UR - http://www.scopus.com/inward/record.url?scp=56349103994&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56349103994&partnerID=8YFLogxK

U2 - 10.1007/s00330-008-1074-y

DO - 10.1007/s00330-008-1074-y

M3 - Article

VL - 18

SP - 2893

EP - 2900

JO - European Radiology

JF - European Radiology

SN - 0938-7994

IS - 12

ER -