Phase-contrast BioCD: High-speed immunoassays at sub-picogram detection levels

Ming Zhao, Leilei Peng, W. Cho, F. Regnier, D. D. Nolte

Research output: Chapter in Book/Report/Conference proceedingConference contribution

10 Citations (Scopus)

Abstract

We previously introduced the biological compact disk (BioCD) as a sensitive detection platform to detect patterned biomolecules immobilized on the surface of a spinning disk. Spinning-disk interferometry allows high speed detection (10 microseconds per spot) of optical path length changes down to sub-nanometer scales with high repeatability. The key to performing stable interferometry on a mechanically spinning disk is self-referencing: locking the phase of the signal and reference beams to quadrature (π/2 phase difference) independent of mechanical vibrations or relative motion. Two quadrature classes of BioCD have been reported previously: the micro-diffraction class (MD-Class) and the adaptive optical class (AO-Class) {Peng, 2004 #565; Varma, 2004 #440}. In this paper, we introduce a third class of BioCD, the Phase-Contrast-Class (PC-Class) BioCD. Protein is immobilized using photolithography on a disk in a 1024 spoke pattern. The edge of the printed protein pattern diffracts a focused laser beam that is detected in the Fourier plane with a split detector. The signal from the split detector is differenced, which plays a role in the electronic domain similar to that of a phase plate in optical phase contrast imaging. The PC-Class BioCD is simple in both theory and implementation, requiring no microstructure fabrication and no complex detection. Its potential in high speed label-free biosensing is demonstrated by a two-analyte immunoassay that shows good rejection of nonspecific binding and low antibody cross-reactivity. Immunoassays were performed against IgG immunoglobulins with detection of bound analyte on pictogram level. To show the potential of scaling up to hundreds or thousands of analytes per disk, an experiment was also performed with small drops of protein solution.

Original languageEnglish (US)
Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6095
DOIs
StatePublished - 2006
Externally publishedYes
EventNanobiophotonics and Biomedical Applications III - San Jose, CA, United States
Duration: Jan 23 2006Jan 24 2006

Other

OtherNanobiophotonics and Biomedical Applications III
CountryUnited States
CitySan Jose, CA
Period1/23/061/24/06

Fingerprint

Proteins
Interferometry
Detectors
Biomolecules
Photolithography
Antibodies
Laser beams
Labels
Diffraction
Imaging techniques
Fabrication
Microstructure
Experiments

Keywords

  • Antibody
  • BioCD
  • Edge diffraction
  • Fourier optics
  • Immunoassay
  • Microarray
  • Molecular recognition
  • Phase contrast imaging
  • Phase-locked quadrature
  • Protein chip
  • Self-referencing interferometry
  • Spinning-disk interferometry

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Zhao, M., Peng, L., Cho, W., Regnier, F., & Nolte, D. D. (2006). Phase-contrast BioCD: High-speed immunoassays at sub-picogram detection levels. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 6095). [60950L] https://doi.org/10.1117/12.646827

Phase-contrast BioCD : High-speed immunoassays at sub-picogram detection levels. / Zhao, Ming; Peng, Leilei; Cho, W.; Regnier, F.; Nolte, D. D.

Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 6095 2006. 60950L.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Zhao, M, Peng, L, Cho, W, Regnier, F & Nolte, DD 2006, Phase-contrast BioCD: High-speed immunoassays at sub-picogram detection levels. in Progress in Biomedical Optics and Imaging - Proceedings of SPIE. vol. 6095, 60950L, Nanobiophotonics and Biomedical Applications III, San Jose, CA, United States, 1/23/06. https://doi.org/10.1117/12.646827
Zhao M, Peng L, Cho W, Regnier F, Nolte DD. Phase-contrast BioCD: High-speed immunoassays at sub-picogram detection levels. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 6095. 2006. 60950L https://doi.org/10.1117/12.646827
Zhao, Ming ; Peng, Leilei ; Cho, W. ; Regnier, F. ; Nolte, D. D. / Phase-contrast BioCD : High-speed immunoassays at sub-picogram detection levels. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. Vol. 6095 2006.
@inproceedings{96b9a99b035c45e5b3997355ebd08e27,
title = "Phase-contrast BioCD: High-speed immunoassays at sub-picogram detection levels",
abstract = "We previously introduced the biological compact disk (BioCD) as a sensitive detection platform to detect patterned biomolecules immobilized on the surface of a spinning disk. Spinning-disk interferometry allows high speed detection (10 microseconds per spot) of optical path length changes down to sub-nanometer scales with high repeatability. The key to performing stable interferometry on a mechanically spinning disk is self-referencing: locking the phase of the signal and reference beams to quadrature (π/2 phase difference) independent of mechanical vibrations or relative motion. Two quadrature classes of BioCD have been reported previously: the micro-diffraction class (MD-Class) and the adaptive optical class (AO-Class) {Peng, 2004 #565; Varma, 2004 #440}. In this paper, we introduce a third class of BioCD, the Phase-Contrast-Class (PC-Class) BioCD. Protein is immobilized using photolithography on a disk in a 1024 spoke pattern. The edge of the printed protein pattern diffracts a focused laser beam that is detected in the Fourier plane with a split detector. The signal from the split detector is differenced, which plays a role in the electronic domain similar to that of a phase plate in optical phase contrast imaging. The PC-Class BioCD is simple in both theory and implementation, requiring no microstructure fabrication and no complex detection. Its potential in high speed label-free biosensing is demonstrated by a two-analyte immunoassay that shows good rejection of nonspecific binding and low antibody cross-reactivity. Immunoassays were performed against IgG immunoglobulins with detection of bound analyte on pictogram level. To show the potential of scaling up to hundreds or thousands of analytes per disk, an experiment was also performed with small drops of protein solution.",
keywords = "Antibody, BioCD, Edge diffraction, Fourier optics, Immunoassay, Microarray, Molecular recognition, Phase contrast imaging, Phase-locked quadrature, Protein chip, Self-referencing interferometry, Spinning-disk interferometry",
author = "Ming Zhao and Leilei Peng and W. Cho and F. Regnier and Nolte, {D. D.}",
year = "2006",
doi = "10.1117/12.646827",
language = "English (US)",
isbn = "0819461377",
volume = "6095",
booktitle = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",

}

TY - GEN

T1 - Phase-contrast BioCD

T2 - High-speed immunoassays at sub-picogram detection levels

AU - Zhao, Ming

AU - Peng, Leilei

AU - Cho, W.

AU - Regnier, F.

AU - Nolte, D. D.

PY - 2006

Y1 - 2006

N2 - We previously introduced the biological compact disk (BioCD) as a sensitive detection platform to detect patterned biomolecules immobilized on the surface of a spinning disk. Spinning-disk interferometry allows high speed detection (10 microseconds per spot) of optical path length changes down to sub-nanometer scales with high repeatability. The key to performing stable interferometry on a mechanically spinning disk is self-referencing: locking the phase of the signal and reference beams to quadrature (π/2 phase difference) independent of mechanical vibrations or relative motion. Two quadrature classes of BioCD have been reported previously: the micro-diffraction class (MD-Class) and the adaptive optical class (AO-Class) {Peng, 2004 #565; Varma, 2004 #440}. In this paper, we introduce a third class of BioCD, the Phase-Contrast-Class (PC-Class) BioCD. Protein is immobilized using photolithography on a disk in a 1024 spoke pattern. The edge of the printed protein pattern diffracts a focused laser beam that is detected in the Fourier plane with a split detector. The signal from the split detector is differenced, which plays a role in the electronic domain similar to that of a phase plate in optical phase contrast imaging. The PC-Class BioCD is simple in both theory and implementation, requiring no microstructure fabrication and no complex detection. Its potential in high speed label-free biosensing is demonstrated by a two-analyte immunoassay that shows good rejection of nonspecific binding and low antibody cross-reactivity. Immunoassays were performed against IgG immunoglobulins with detection of bound analyte on pictogram level. To show the potential of scaling up to hundreds or thousands of analytes per disk, an experiment was also performed with small drops of protein solution.

AB - We previously introduced the biological compact disk (BioCD) as a sensitive detection platform to detect patterned biomolecules immobilized on the surface of a spinning disk. Spinning-disk interferometry allows high speed detection (10 microseconds per spot) of optical path length changes down to sub-nanometer scales with high repeatability. The key to performing stable interferometry on a mechanically spinning disk is self-referencing: locking the phase of the signal and reference beams to quadrature (π/2 phase difference) independent of mechanical vibrations or relative motion. Two quadrature classes of BioCD have been reported previously: the micro-diffraction class (MD-Class) and the adaptive optical class (AO-Class) {Peng, 2004 #565; Varma, 2004 #440}. In this paper, we introduce a third class of BioCD, the Phase-Contrast-Class (PC-Class) BioCD. Protein is immobilized using photolithography on a disk in a 1024 spoke pattern. The edge of the printed protein pattern diffracts a focused laser beam that is detected in the Fourier plane with a split detector. The signal from the split detector is differenced, which plays a role in the electronic domain similar to that of a phase plate in optical phase contrast imaging. The PC-Class BioCD is simple in both theory and implementation, requiring no microstructure fabrication and no complex detection. Its potential in high speed label-free biosensing is demonstrated by a two-analyte immunoassay that shows good rejection of nonspecific binding and low antibody cross-reactivity. Immunoassays were performed against IgG immunoglobulins with detection of bound analyte on pictogram level. To show the potential of scaling up to hundreds or thousands of analytes per disk, an experiment was also performed with small drops of protein solution.

KW - Antibody

KW - BioCD

KW - Edge diffraction

KW - Fourier optics

KW - Immunoassay

KW - Microarray

KW - Molecular recognition

KW - Phase contrast imaging

KW - Phase-locked quadrature

KW - Protein chip

KW - Self-referencing interferometry

KW - Spinning-disk interferometry

UR - http://www.scopus.com/inward/record.url?scp=33745212903&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745212903&partnerID=8YFLogxK

U2 - 10.1117/12.646827

DO - 10.1117/12.646827

M3 - Conference contribution

AN - SCOPUS:33745212903

SN - 0819461377

SN - 9780819461377

VL - 6095

BT - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

ER -