Pressure loss in constriction microchannels

Wing Yin Lee, Man Wong, Yitshak Zohar

Research output: Contribution to journalArticle

47 Citations (Scopus)

Abstract

Constriction devices contain elements inserted into the fluid stream, which change the local streamwise flow area. One such element is the orifice-like obstruction with sharp corners, a back-to-back abrupt contraction and expansion, which could trigger flow separation. A series of microchannels, 40 μm × 1 μm × 4000 μm in nominal dimensions, with constriction elements at the centers of the channels has been fabricated using standard micromachining techniques. The channel widths at the constriction sections varied from 10 μm to 34 μm, with pressure sensors integrated in each channel. Nitrogen gas was passed through the microdevices under inlet pressure up to 50 psi. The mass flow rates were measured for all the devices as a function of the pressure drop. A monotonic decrease of the flow rate with decreasing constriction-gap width was observed. The pressure distribution along the microchannel with the smallest constriction gap showed a pressure drop across the constriction element. Both mass flow rate and pressure measurements indicate that flow separation from the constriction sharp corners could occur.

Original languageEnglish (US)
Pages (from-to)236-244
Number of pages9
JournalJournal of Microelectromechanical Systems
Volume11
Issue number3
DOIs
StatePublished - Jun 2002
Externally publishedYes

Fingerprint

Microchannels
Flow separation
Flow rate
Pressure drop
Micromachining
Pressure sensors
Pressure measurement
Orifices
Pressure distribution
Nitrogen
Fluids
Gases

Keywords

  • Constriction microchannel
  • Flow rate
  • Flow separation
  • Minor pressure loss
  • Pressure distribution

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Mechanical Engineering

Cite this

Pressure loss in constriction microchannels. / Lee, Wing Yin; Wong, Man; Zohar, Yitshak.

In: Journal of Microelectromechanical Systems, Vol. 11, No. 3, 06.2002, p. 236-244.

Research output: Contribution to journalArticle

Lee, Wing Yin ; Wong, Man ; Zohar, Yitshak. / Pressure loss in constriction microchannels. In: Journal of Microelectromechanical Systems. 2002 ; Vol. 11, No. 3. pp. 236-244.
@article{ad4fb16ed2f9484f9e282ebaed5409c0,
title = "Pressure loss in constriction microchannels",
abstract = "Constriction devices contain elements inserted into the fluid stream, which change the local streamwise flow area. One such element is the orifice-like obstruction with sharp corners, a back-to-back abrupt contraction and expansion, which could trigger flow separation. A series of microchannels, 40 μm × 1 μm × 4000 μm in nominal dimensions, with constriction elements at the centers of the channels has been fabricated using standard micromachining techniques. The channel widths at the constriction sections varied from 10 μm to 34 μm, with pressure sensors integrated in each channel. Nitrogen gas was passed through the microdevices under inlet pressure up to 50 psi. The mass flow rates were measured for all the devices as a function of the pressure drop. A monotonic decrease of the flow rate with decreasing constriction-gap width was observed. The pressure distribution along the microchannel with the smallest constriction gap showed a pressure drop across the constriction element. Both mass flow rate and pressure measurements indicate that flow separation from the constriction sharp corners could occur.",
keywords = "Constriction microchannel, Flow rate, Flow separation, Minor pressure loss, Pressure distribution",
author = "Lee, {Wing Yin} and Man Wong and Yitshak Zohar",
year = "2002",
month = "6",
doi = "10.1109/JMEMS.2002.1007402",
language = "English (US)",
volume = "11",
pages = "236--244",
journal = "Journal of Microelectromechanical Systems",
issn = "1057-7157",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

TY - JOUR

T1 - Pressure loss in constriction microchannels

AU - Lee, Wing Yin

AU - Wong, Man

AU - Zohar, Yitshak

PY - 2002/6

Y1 - 2002/6

N2 - Constriction devices contain elements inserted into the fluid stream, which change the local streamwise flow area. One such element is the orifice-like obstruction with sharp corners, a back-to-back abrupt contraction and expansion, which could trigger flow separation. A series of microchannels, 40 μm × 1 μm × 4000 μm in nominal dimensions, with constriction elements at the centers of the channels has been fabricated using standard micromachining techniques. The channel widths at the constriction sections varied from 10 μm to 34 μm, with pressure sensors integrated in each channel. Nitrogen gas was passed through the microdevices under inlet pressure up to 50 psi. The mass flow rates were measured for all the devices as a function of the pressure drop. A monotonic decrease of the flow rate with decreasing constriction-gap width was observed. The pressure distribution along the microchannel with the smallest constriction gap showed a pressure drop across the constriction element. Both mass flow rate and pressure measurements indicate that flow separation from the constriction sharp corners could occur.

AB - Constriction devices contain elements inserted into the fluid stream, which change the local streamwise flow area. One such element is the orifice-like obstruction with sharp corners, a back-to-back abrupt contraction and expansion, which could trigger flow separation. A series of microchannels, 40 μm × 1 μm × 4000 μm in nominal dimensions, with constriction elements at the centers of the channels has been fabricated using standard micromachining techniques. The channel widths at the constriction sections varied from 10 μm to 34 μm, with pressure sensors integrated in each channel. Nitrogen gas was passed through the microdevices under inlet pressure up to 50 psi. The mass flow rates were measured for all the devices as a function of the pressure drop. A monotonic decrease of the flow rate with decreasing constriction-gap width was observed. The pressure distribution along the microchannel with the smallest constriction gap showed a pressure drop across the constriction element. Both mass flow rate and pressure measurements indicate that flow separation from the constriction sharp corners could occur.

KW - Constriction microchannel

KW - Flow rate

KW - Flow separation

KW - Minor pressure loss

KW - Pressure distribution

UR - http://www.scopus.com/inward/record.url?scp=0036600997&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036600997&partnerID=8YFLogxK

U2 - 10.1109/JMEMS.2002.1007402

DO - 10.1109/JMEMS.2002.1007402

M3 - Article

VL - 11

SP - 236

EP - 244

JO - Journal of Microelectromechanical Systems

JF - Journal of Microelectromechanical Systems

SN - 1057-7157

IS - 3

ER -